scholarly journals Effects of endovascular cooling on infarct size in ST-segment elevation myocardial infarction: A patient-level pooled analysis from randomized trials

2017 ◽  
Vol 31 (3) ◽  
pp. 269-276 ◽  
Author(s):  
Michael Dae ◽  
William O'Neill ◽  
Cindy Grines ◽  
Simon Dixon ◽  
David Erlinge ◽  
...  
2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
L.S.M Kerkmeijer ◽  
G Chao ◽  
R Tijssen ◽  
T Gori ◽  
R.P Kraak ◽  
...  

Abstract Introduction Bioresorbable vascular scaffolds (BVS) use appears theoretically attractive in patients presenting with ST-segment elevation myocardial infarction (STEMI) as acute lesions are generally composed of soft plaques, in which optimal BVS deployment and expansion is easier to achieve. Furthermore, those patients are generally younger and would benefit longer from the promise of vascular restoration therapy. Purpose In this patient level pooled analysis of two clinical trials, we evaluated the clinical outcomes of Absorb BVS versus Xience everolimus-eluting stent (EES) in STEMI patients at 2-year follow-up. Methods We performed an individual patient-level pooled analysis of the AIDA and COMPARE-ABSORB trials in which 3515 patient were randomly assigned to Absorb BVS (n=1772) or Xience EES (n=1743). Clinical outcomes in STEMI patients were analyzed by randomized treatment assignment cumulative through 2 years. The primary efficacy outcomes measure was target lesion failure (cardiac death, target-vessel myocardial infarction or target lesion revascularization), and the primary safety outcome measure was device thrombosis at 2-year follow-up. Results 350 (19.8%) STEMI patients were allocated to Absorb BVS versus 328 (18.8%) to Xience EES. The mean age of patient presenting with STEMI was 60 years old, 76.0% were males and 15.3% had diabetes mellitus. At 2-years target lesion failure occurred in 8.4% of BVS STEMI patients and 6.2% of EES STEMI patients (p=0.253). The 2-year rates of cardiac death (2.6% vs 1.6%, p=0.332), TV-MI (4.7% vs 2.5%) and TLR (6.8% vs 4.1%) were not significantly different. The 2-year incidence of definite device thrombosis was 4.7% in Absorb BVS versus 1.8% in Xience EES (p=0.045). Conclusion In the present patient-level pooled analysis of the AIDA and COMPARE-Absorb trials, BVS was associated with increased rates of device thrombosis in STEMI patients compared to Xience EES. Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Abbott


2012 ◽  
Vol 59 (24) ◽  
pp. 2175-2181 ◽  
Author(s):  
Franck Thuny ◽  
Olivier Lairez ◽  
François Roubille ◽  
Nathan Mewton ◽  
Gilles Rioufol ◽  
...  

2015 ◽  
Vol 192 ◽  
pp. 22-23 ◽  
Author(s):  
Hans-Josef Feistritzer ◽  
Gert Klug ◽  
Sebastian Johannes Reinstadler ◽  
Johannes Mair ◽  
Michael Schocke ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document