TU-AB-201-02: An Automated Treatment Plan Quality Assurance Program for Tandem and Ovoid High Dose-Rate Brachytherapy

2015 ◽  
Vol 42 (6Part31) ◽  
pp. 3594-3594
Author(s):  
J Tan ◽  
F Shi ◽  
B Hrycushko ◽  
P Medin ◽  
S Stojadinovic ◽  
...  
Brachytherapy ◽  
2015 ◽  
Vol 14 ◽  
pp. S67
Author(s):  
Feng Shi ◽  
Brian Hrycushko ◽  
Jun Tan ◽  
Paul Medin ◽  
Strahinja Stojadinovic ◽  
...  

Brachytherapy ◽  
2014 ◽  
Vol 13 ◽  
pp. S98
Author(s):  
Antonio L. Damato ◽  
Christina Molodowitch ◽  
Jorgen L. Hansen ◽  
Robert A. Cormack ◽  
Desmond A. O'Farrell ◽  
...  

2015 ◽  
Vol 115 ◽  
pp. S139-S140
Author(s):  
A. Espinoza ◽  
M. Petasecca ◽  
I. Fuduli ◽  
A. Howie ◽  
S. Corde ◽  
...  

2010 ◽  
Vol 37 (7Part3) ◽  
pp. 3910-3910
Author(s):  
D Rickey ◽  
D Sasaki ◽  
J Bews

Brachytherapy ◽  
2020 ◽  
Vol 19 (4) ◽  
pp. 518-531 ◽  
Author(s):  
Christopher L. Deufel ◽  
Marina A. Epelman ◽  
Kalyan S. Pasupathy ◽  
Mustafa Y. Sir ◽  
Victor W. Wu ◽  
...  

2010 ◽  
Vol 37 (6Part1) ◽  
pp. 2525-2532 ◽  
Author(s):  
Daniel W. Rickey ◽  
David Sasaki ◽  
Jeff Bews

Brachytherapy ◽  
2016 ◽  
Vol 15 (2) ◽  
pp. 252-262 ◽  
Author(s):  
Vasiliki Peppa ◽  
Evaggelos Pantelis ◽  
Eleftherios Pappas ◽  
Vasileios Lahanas ◽  
Constantinos Loukas ◽  
...  

Author(s):  
Tania Afroz ◽  
Pretam K. Das ◽  
S. I. Chawdhury ◽  
Shudeb K. Roy

Aim of this work is to calibrate the high dose rate (HDR) brachytherapy source 60Co. The radioactive source calibration is a very important part of the quality assurance program for dosimetry of brachytherapy source. The goal of this project is the calibration of HDR Brachytherapy source in radiation therapy is the measurement of the air kerma rate which required actual dose to deliver. The source calibration is an essential part of the quality assurance program for dosimetry of brachytherapy source. This research will help the patient who is involving brachytherapy treatment. HDR brachytherapy source 60Co is inserted directly or in close to the tumor. Most commonly using method for calibration of HDR brachytherapy source 60CO is well type ionization chamber. Calibration of the radioactive source 60Co brachytherapy source is very important for the treatment of cancer patient. We have got the variation between RAKR from TPS and measured Air Kerma Rate of 60Co brachytherapy source are 3.2% and 3.04% and which give very good agreement with the Air Kerma Rate (RAKR) is 5% (from BEBIG protocol, Germany). So, our results were satisfied for brachytherapy treatment. From these results, it must be concluded that, 60Co brachytherapy source is suitable for brachytherapy cancer treatment. It is very difficult to calculate treatment deliver dose without calibrating AKR of HDR brachytherapy source. It is very important to verify the calculated Air Kerma Rate by TPS Air Kerma Rate.