DELAYED RUPTURE OF EXTENSOR DIGITORUM COMMUNIS TENDON FOLLOWING VOLAR PLATING OF DISTAL RADIUS FRACTURE

Hand Surgery ◽  
2008 ◽  
Vol 13 (03) ◽  
pp. 183-185 ◽  
Author(s):  
Yasunori Hattori ◽  
Kazuteru Doi ◽  
Soutetsu Sakamoto ◽  
Kiminori Yukata

We present a case of delayed rupture of extensor digitorum communis tendon seven years after volar plating of distal radius fracture. Drill bit penetration during surgery and prominent screw tips into the fourth extensor compartment have a potential risk to damage the tendons. Careful and accurate use of internal fixation instruments is necessary to avoid this complication.

2018 ◽  
Vol 23 (2) ◽  
pp. 87
Author(s):  
Tae Gyun Kim ◽  
Youn Moo Heo ◽  
Jin Woong Yi ◽  
Byung Hak Oh ◽  
Chang Uk Ham

Hand Surgery ◽  
2006 ◽  
Vol 11 (01n02) ◽  
pp. 67-70 ◽  
Author(s):  
Siu Cheong Koo ◽  
Sheung Tung Ho

Flexor tendon rupture following distal radius fracture is rare. We described a case of flexor pollicis longus rupture, presented five years after volar plating of distal radius fracture.


2019 ◽  
Vol 21 ◽  
pp. 100198
Author(s):  
Shingo Komura ◽  
Akihiro Hirakawa ◽  
Kyosuke Yamamoto ◽  
Koki Kato ◽  
Marie Nohara ◽  
...  