scholarly journals Recent advances in treatment of pancreatic pseudocyst with endoscopic ultrasonography guided lumen-apposing metal stents

2020 ◽  
Vol 28 (5) ◽  
pp. 189-196
Author(s):  
Wen-Bin Ran ◽  
Jing Shan ◽  
Xiao-Bin Sun
2006 ◽  
Vol 53 (3/4) ◽  
pp. 89-94 ◽  
Author(s):  
YOSHINOBU OKABE ◽  
OSAMU TSURUTA ◽  
YUKI WADA ◽  
KAZUHIKO WADA ◽  
HIDEYA SUGA ◽  
...  

2017 ◽  
Vol 15 (3) ◽  
pp. 459-460 ◽  
Author(s):  
Bojan Kovacevic ◽  
Peter Vilmann ◽  
John Gásdal Karstensen

2015 ◽  
Vol 4 (3) ◽  
pp. 271 ◽  
Author(s):  
Siyu Dr. ◽  
Xiang Liu ◽  
Sheng Wang ◽  
Nan Ge ◽  
Guoxin Wang ◽  
...  

2000 ◽  
Vol 56 (2) ◽  
pp. 94-95
Author(s):  
Shoryoku Hino ◽  
Hiroshi Kakutani ◽  
Keiichi Ikeda ◽  
Yujiro Uchiyama ◽  
Kazuki Sumiyama ◽  
...  

2021 ◽  
Vol 93 (6) ◽  
pp. AB235-AB236
Author(s):  
Yusuke Takasaki ◽  
Hiroyuki Isayama ◽  
Kyoung Sub Shin ◽  
Jong Pil Moon ◽  
Shigeto Ishii ◽  
...  

2013 ◽  
Vol 26 (4) ◽  
pp. 599-602 ◽  
Author(s):  
Jessica Widmer ◽  
Paloma Alvarez ◽  
Monica Gaidhane ◽  
Naveen Paddu ◽  
Hiren Umrania ◽  
...  

2017 ◽  
Vol 5 (4) ◽  
pp. 213-219 ◽  
Author(s):  
Nan Ge ◽  
Jinlong Hu ◽  
Siyu Sun ◽  
Enqiang Linghu ◽  
Zhendong Jin ◽  
...  

Abstract Objective To compare the efficiency of plastic and metal stents for symptomatic pancreatic pseudocyst (PP) drainage and analyze other main associated factors that affect the outcome of drainage therapy. Method Rates of technical and clinical success, procedure-related side effects (hemorrhage, stent migration, and cyst rupture), reinterventions, and duration of hospital stay. Results There were 52 patients, 40 patients underwent plastic stent placement and 12 patients underwent lumen-apposing metal stent (LAMS) placement. The total rate of technical success was 100%. The total rate of clinical success was 100%. The total rate of adverse events was 7.7% (4/52). On multiple logistic regression analysis, the use of plastic stents (P < 0.05, Exp B = 12.168) and the presence of a large cyst (P < 0.05, Exp B = 1.036) were shown to significantly increase the risk of reintervention. On multivariate linear regression analysis, etiology of pseudocyst (P < 0.05, B = −8.427, −9.785, −5.514) was associated with prolonged hospital stent, while stent type was not shown be a factor (P > 0.05). Conclusion Both plastic and LAMSs are proven to be highly efficient in PP drainage. The LAMS is superior in preventing complications such as migration and cyst leakage and reducing the rate of reintervention.


Sign in / Sign up

Export Citation Format

Share Document