Safety and efficacy of lumen-apposing metal stents with and without simultaneous double-pigtail plastic stents for draining pancreatic pseudocyst

2018 ◽  
Vol 87 (5) ◽  
pp. 1248-1255 ◽  
Author(s):  
Murad Aburajab ◽  
Zachary Smith ◽  
Abdul Khan ◽  
Kulwinder Dua
2020 ◽  
Vol 91 (6) ◽  
pp. AB509-AB510
Author(s):  
Vinay Chandrasekhara ◽  
Marc Barthet ◽  
Fateh Bazerbachi ◽  
Joyce Peetermans ◽  
Edmund McMullen ◽  
...  

2018 ◽  
Vol 06 (06) ◽  
pp. E714-E721 ◽  
Author(s):  
Darren Ballard ◽  
Syed Rahman ◽  
Brian Ginnebaugh ◽  
Abdul Khan ◽  
Kulwinder Dua

Abstract Background and study aims Durable biliary drainage is essential during neoadjuvant therapy (NAT) in patients with pancreatic cancer who present with biliary obstruction. Plastic stents (PS) tend to occlude readily, resulting in delay/interruption of treatment. Our aim was to evaluate the safety and efficacy of self-expanding metal stents (SEMS) for biliary drainage in patients receiving NAT for pancreatic cancer. Patients and methods From 2009 to 2014, all consecutive patients with resectable pancreatic cancer at one tertiary center had SEMS placed for biliary drainage before NAT was started. Data on biliary drainage efficacy, stent malfunction rates and procedural adverse events were collected. Results One hundred forty-two consecutive patients with pancreatic cancer (mean age 66 ± 9 SD years; 81 male, 61 female; 67 resectable, 75 borderline resectable) were enrolled. Eight-seven patients (61 %) had prior PS exchanged to SEMS and 55 (39 %) had SEMS placed upfront. Median duration from SEMS placement to the end of NAT/surgery was 111 days (range 44 – 282). During NAT, SEMS malfunction requiring reintervention occurred in 16 patients (11.2 %): tissue ingrowth 11, stent occlusion from food 6, stent migration 3, incomplete expansion 1, “tissue cheese-cutter” effect 1, and cystic duct obstruction 1. On subgroup analysis, no correlation between SEMS malfunction and stage of disease, prior PS, or duration of NAT was found (r2 = 0.05, P = 0.34). Presence of SEMS in situ did not affect pancreaticoduodenectomy. Conclusion SEMS provide safe, effective and durable biliary drainage during NAT for pancreas cancer. Previously placed PS can be exchanged for SEMS. SEMS do not require removal prior to surgery.Meeting presentations: Digestive Disease Week 2015 and 2017


2017 ◽  
Vol 5 (4) ◽  
pp. 213-219 ◽  
Author(s):  
Nan Ge ◽  
Jinlong Hu ◽  
Siyu Sun ◽  
Enqiang Linghu ◽  
Zhendong Jin ◽  
...  

Abstract Objective To compare the efficiency of plastic and metal stents for symptomatic pancreatic pseudocyst (PP) drainage and analyze other main associated factors that affect the outcome of drainage therapy. Method Rates of technical and clinical success, procedure-related side effects (hemorrhage, stent migration, and cyst rupture), reinterventions, and duration of hospital stay. Results There were 52 patients, 40 patients underwent plastic stent placement and 12 patients underwent lumen-apposing metal stent (LAMS) placement. The total rate of technical success was 100%. The total rate of clinical success was 100%. The total rate of adverse events was 7.7% (4/52). On multiple logistic regression analysis, the use of plastic stents (P < 0.05, Exp B = 12.168) and the presence of a large cyst (P < 0.05, Exp B = 1.036) were shown to significantly increase the risk of reintervention. On multivariate linear regression analysis, etiology of pseudocyst (P < 0.05, B = −8.427, −9.785, −5.514) was associated with prolonged hospital stent, while stent type was not shown be a factor (P > 0.05). Conclusion Both plastic and LAMSs are proven to be highly efficient in PP drainage. The LAMS is superior in preventing complications such as migration and cyst leakage and reducing the rate of reintervention.


2020 ◽  
Vol 08 (11) ◽  
pp. E1639-E1653
Author(s):  
Vinay Chandrasekhara ◽  
Marc Barthet ◽  
Jacques Devière ◽  
Fateh Bazerbachi ◽  
Sundeep Lakhtakia ◽  
...  

Abstract Background and study aims Lumen-apposing metal stents (LAMS) are increasingly used for drainage of walled-off pancreatic necrosis (WON). Recent studies suggested greater adverse event (AE) rates with LAMS for WON. We conducted a systematic review and meta-analysis to compare the safety and efficacy of LAMS with double-pigtail plastic stents (DPPS) for endoscopic drainage of WON. The primary aim was to evaluate stent-related AEs. Methods In October 2019, we searched the Ovid (Embase, MEDLINE, Cochrane) and Scopus databases for studies assessing a specific LAMS or DPPS for WON drainage conducted under EUS guidance. Safety outcomes were AE rates of bleeding, stent migration, perforation, and stent occlusion. Efficacy outcomes were WON resolution and number of procedures needed to achieve resolution. A subanalysis including non-EUS-guided cases was performed. Results Thirty studies including one randomized controlled trial (total 1,524 patients) were analyzed. LAMS were associated with similar bleeding (2.5 % vs. 4.6 %, P = 0.39) and perforation risk (0.5 % vs. 1.1 %, P = 0.35) compared to DPPS. WON resolution (87.4 % vs. 87.5 %, P = 0.99), number of procedures to achieve resolution (2.09 vs. 1.88, P = 0.72), stent migration (5.9 % vs. 6.8 %, P = 0.79), and stent occlusion (3.8 % vs. 5.2 %, P = 0.78) were similar for both groups. Inclusion of non-EUS-guided cases led to significantly higher DPPS bleeding and perforation rates. Conclusions LAMS and DPPS were associated with similar rates of AEs and WON resolution when limiting analysis to EUS-guided cases. Higher bleeding rates were seen in historical studies of DPPS without EUS guidance. Additional high-quality studies of WON treatment using consistent outcome definitions are needed.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sang Hoon Lee ◽  
Yeon Suk Kim ◽  
Eui Joo Kim ◽  
Hee Seung Lee ◽  
Jeong Youp Park ◽  
...  

AbstractChronic pancreatitis (CP) related main pancreatic duct (MPD) stricture has been a challenge for endoscopists. Fully covered self-expandable metal stents (FC-SEMS) has been tried in CP patients, but the efficacy and safety are still controversial. Thus, we aim to compare the long-term clinical efficacy of FC-SEMS vs. plastic stent placement in persistent MPD strictures secondary to CP. Between 2007 and 2018, 80 chronic pancreatitis patients (58 males, median age 49 years), who underwent endoscopic placement of FC-SEMS (n = 26) and plastic stent (n = 54) for persistent MPD strictures after at least 3 months of initial single plastic stenting, were retrospectively analyzed during a median follow-up duration of 33.7 months. As a result, MPD stricture resolution rate was statistically higher in FC-SEMS group (87.0% vs. 42.0%, p < 0.001). Although immediate complications occurred similarly (38.5% vs. 37.0%, p = 0.902), spontaneous migration (26.9%) and de novo strictures (23.1%) were pronounced delayed complications in FC-SEMS group. Pain relief during follow-up was significantly higher in FC-SEMS group (76.9% vs. 53.7%, p = 0.046). The total procedure cost was similar in both groups ($1,455.6 vs. $1,596.9, p = 0.486). In comparison with plastic stent, FC-SEMS placement for persistent MPD strictures had favorable long-term clinical efficacy, with its typical complications like spontaneous migration and de novo strictures.


2021 ◽  
Vol 09 (06) ◽  
pp. E888-E894
Author(s):  
Nichol S. Martinez ◽  
Sumant Inamdar ◽  
Sheila N. Firoozan ◽  
Stephanie Izard ◽  
Calvin Lee ◽  
...  

Abstract Background and study aims There are conflicting data regarding the risk of post-ERCP pancreatitis (PEP) with self-expandable metallic stents (SEMS) compared to polyethylene stents (PS) in malignant biliary obstructions and limited data related to benign obstructions. Patients and methods A retrospective cohort study was performed of 1136 patients who underwent ERCP for biliary obstruction and received SEMS or PS at a tertiary-care medical center between January 2011 and October 2016. We evaluated the association between stent type (SEMS vs PS) and PEP in malignant and benign biliary obstructions. Results Among the 1136 patients included in our study, 399 had SEMS placed and 737 had PS placed. Patients with PS were more likely to have pancreatic duct cannulation, pancreatic duct stent placement, double guidewire technique, sphincterotomy and sphincteroplasty as compared to the SEMS group. On multivariate analysis, PEP rates were higher in the SEMS group (8.0 %) versus the PS group (4.8 %) (OR 2.27 [CI, 1.22, 4.24]) for all obstructions. For malignant obstructions, PEP rates were 7.8 % and 6.6 % for SEMS and plastic stents, respectively (OR 1.54 [CI, 0.72, 3.30]). For benign obstructions the PEP rate was higher in the SEMS group (8.8 %) compared to the PS group (4.2 %) (OR 3.67 [CI, 1.50, 8.97]). No significant differences between PEP severity were identified based on stent type when stratified based on benign and malignant. Conclusions PEP rates were higher when SEMS were used for benign obstruction as compared to PS. For malignant obstruction, no difference was identified in PEP rates with use of SEMS vs PS.