Negative Matrix-Assisted Laser Desorption/Ionization Time-of-Flight/Time-of-Flight Tandem Mass Spectrometry Fragmentation of Synthetic Analogs of the O-Specific Polysaccharide of Vibrio Cholerae O:1 in the Presence of Anionic Dopants

2007 ◽  
Vol 13 (5) ◽  
pp. 347-353 ◽  
Author(s):  
Josef Chmelík ◽  
Pavel Řehulka ◽  
Vladimír Kováčik ◽  
Vladimír Pätoprstý ◽  
Pavol Kováč

Oligosaccharides (tri- to hexamers) that represent terminal epitopes of O-antigens of Vibrio cholerae O:1, serotypes Ogawa and Inaba, have been studied by negative matrix-assisted laser desorption/ionization time-of-flight/time-of-flight mass spectrometry (MALDI-ToF/ToF MS). The [M – H+]− ions are formed after expulsion of a proton from molecules studied under MALDI/MS analysis conditions in the negative mode. Several ammonium salts (chloride, nitrate, hydrogencarbonate and hydrogensulfate) were used as additives to increase the formation of negative ions from saccharides. The most efficient was the addition of ammonium hydrogencarbonate, which increased the number of [M – H+]− ions more than six times. Between three fragmentation pathways, the new conjugated transfer of electrons within the second downstream unit of oligosaccharides was discovered. Production of these ions, which has not been observed in any other kinds of measurement, distinguishes substances belonging to Ogawa and Inaba serotypes. The negative MALDI-ToF/ToF mass spectra are simpler and, at the same time, more informative, as compared with positive and negative electrospray ionization ion trap as well as with positive MALDI-ToF/ToF analysis.


2016 ◽  
Vol 55 (1) ◽  
pp. 90-96 ◽  
Author(s):  
Julie Denis ◽  
Marie Machouart ◽  
Florent Morio ◽  
Marcela Sabou ◽  
Catherine Kauffmann-LaCroix ◽  
...  

ABSTRACT The genus Malassezia comprises commensal yeasts on human skin. These yeasts are involved in superficial infections but are also isolated in deeper infections, such as fungemia, particularly in certain at-risk patients, such as neonates or patients with parenteral nutrition catheters. Very little is known about Malassezia epidemiology and virulence. This is due mainly to the difficulty of distinguishing species. Currently, species identification is based on morphological and biochemical characteristics. Only molecular biology techniques identify species with certainty, but they are time-consuming and expensive. The aim of this study was to develop and evaluate a matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) database for identifying Malassezia species by mass spectrometry. Eighty-five Malassezia isolates from patients in three French university hospitals were investigated. Each strain was identified by internal transcribed spacer sequencing. Forty-five strains of the six species Malassezia furfur , M. sympodialis , M. slooffiae , M. globosa , M. restricta , and M. pachydermatis allowed the creation of a MALDI-TOF database. Forty other strains were used to test this database. All strains were identified by our Malassezia database with log scores of >2.0, according to the manufacturer's criteria. Repeatability and reproducibility tests showed a coefficient of variation of the log score values of <10%. In conclusion, our new Malassezia database allows easy, fast, and reliable identification of Malassezia species. Implementation of this database will contribute to a better, more rapid identification of Malassezia species and will be helpful in gaining a better understanding of their epidemiology.



2013 ◽  
Vol 34 (9) ◽  
pp. 990-995 ◽  
Author(s):  
Pranita D. Tamma ◽  
Kennard Tan ◽  
Veronique R. Nussenblatt ◽  
Alison E. Turnbull ◽  
Karen C. Carroll ◽  
...  

We evaluated 222 hospitalized patients whose clinical isolates were tested using standard methods and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF). MALDI-TOF could have reduced time to appropriate therapy for 28.8% and 44.6% patients based on the treating physician's choices and stewardship team recommendations, respectively. Clinicians should be aware of scenarios in which MALDI-TOF can optimize antibiotic therapy.



2015 ◽  
Vol 54 (1) ◽  
pp. 5-6 ◽  
Author(s):  
Neil W. Anderson

An article in this issue of theJournal of Clinical Microbiology(J.-H. Youn, S. K. Drake, R. A. Weingarten, K. M. Frank, J. P. Dekker, and A. F. Lau, J Clin Microbiol 53:35–42, 2015,http://dx.doi.org/10.1128/JCM.01643-15) describes the use of matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry for the detection of organisms carrying ablaKPC-containing plasmid. This powerful and promising application highlights the challenges of using MALDI-TOF mass spectrometry for purposes other than organism identification.



2015 ◽  
Vol 53 (7) ◽  
pp. 2163-2171 ◽  
Author(s):  
Camille Lasserre ◽  
Luc De Saint Martin ◽  
Gaelle Cuzon ◽  
Pierre Bogaerts ◽  
Estelle Lamar ◽  
...  

The recognition of carbapenemase-producingEnterobacteriaceae(CPE) isolates is a major laboratory challenge, and their inappropriate or delayed detection may have negative impacts on patient management and on the implementation of infection control measures. We describe here a matrix-assisted laser desorption ionization−time of flight (MALDI-TOF)-based method to detect carbapenemase activity inEnterobacteriaceae. After a 20-min incubation of the isolate with 0.5 mg/ml imipenem at 37°C, supernatants were analyzed by MALDI-TOF in order to identify peaks corresponding to imipenem (300 Da) and an imipenem metabolite (254 Da). A total of 223 strains, 77 CPE (OXA-48 variants, KPC, NDM, VIM, IMI, IMP, and NMC-A) and 146 non-CPE (cephalosporinases, extended-spectrum β-lactamases [ESBLs], and porin defects), were tested and used to calculate a ratio of imipenem hydrolysis: mass spectrometry [MS] ratio = metabolite/(imipenem + metabolite). An MS ratio cutoff was statistically determined to classify strains as carbapenemase producers (MS ratio of ≥0.82). We validated this method first by testing 30 of our 223 isolates (15 CPE and 15 non-CPE) 10 times to calculate an intraclass correlation coefficient (ICC of 0.98), showing the excellent repeatability of the method. Second, 43 strains (25 CPE and 18 non-CPE) different from the 223 strains used to calculate the ratio cutoff were used as external controls and blind tested. They yielded sensitivity and specificity of 100%. The total cost per test is <0.10 U.S. dollars (USD). This easy-to-perform assay is time-saving, cost-efficient, and highly reliable and might be used in any routine laboratory, given the availability of mass spectrometry, to detect CPE.



Sign in / Sign up

Export Citation Format

Share Document