The use of autologous femoral vein for the repair of the common iliac vein after resection of a pheochromocytoma

2008 ◽  
Vol 23 (5) ◽  
pp. 227-229 ◽  
Author(s):  
M Simms ◽  
M S Mehat ◽  
J A C Buckels

Aim To illustrate the use of autologous femoral vein for grafting ilio-caval vein defects following abdomino-pelvic tumour resections. Methods Case report and literature review. Results Durable restoration of ilio-caval patency was achieved, with minimal morbidity from graft harvesting. Conclusions Autologous femoral vein presents a viable graft option for the immediate reconstruction of large intra-abdominal vein deficits.

2021 ◽  
Vol 9 (4) ◽  
pp. 360-360
Author(s):  
Fei Li ◽  
Ruili Zhang ◽  
Jiangping Chen ◽  
Xiang Wang ◽  
Haiwei Chu ◽  
...  

1994 ◽  
Vol 44 (1) ◽  
pp. 69-73
Author(s):  
TAKASI YOSHIDA ◽  
SUSUMU ISHIKAWA ◽  
MASAHIRO AIZAKI ◽  
AKIO OOTAKI ◽  
KAZUHIRO SAKATA ◽  
...  

2019 ◽  
Vol 66 (1.2) ◽  
pp. 205-208 ◽  
Author(s):  
Masashi Kano ◽  
Toshihiko Nishisho ◽  
Ryo Miyagi ◽  
Fumio Chikugo ◽  
Eiji Kudo ◽  
...  

2015 ◽  
Vol 21 (1) ◽  
pp. 12-16 ◽  
Author(s):  
Oana Popa ◽  
P. Bordei ◽  
C. Ionescu ◽  
D.M. Iliescu

Abstract The diameter at the origin of the internal iliac vein was found between 4.7 to 9.9 mm; for the right internal iliac vein between 4.7 to 9.7 mm; the statistical distribution groups value in ascending order being as follows: 4.7 to 5.5 mm: 4 cases (22.22% of cases); 6.9 to 7.8 mm: 6 cases (33.33% of cases); 8.4-8.8 mm: 4 cases (22.22% of cases); 9.1 to 9.7 mm: 4 cases (22.22% of cases). The diameter at the origin of the left internal iliac vein was between 4.8 to 9.9 mm, while the distribution statistics on groups of values, in ascending order, being as follows: 4.8-5.2 mm: 4 cases (22.22 % of cases); 6.8-7.1 mm: 8 cases (44.44% of cases); 8.3 to 9.9 mm: 6 cases (33.33% of cases). The diameter at the end of the internal iliac vein was between 5.9 to 10.2 mm; the diameter at the end of the right internal iliac vein was between 6.1 to 10.2 mm, the statistical distribution of values groups in ascending order being follows: 6.1 to 7.5 mm: 6 cases (33.33% of cases); 8.4 to 8.7 mm: 8 cases (44.44% of cases); 9.3 to 10.2 mm: 4 cases (22.22% of cases). The diameter at the end of the left internal iliac vein was between 5.9 to 9.9 mm, while the distribution statistics on groups of values in ascending order being as follows: 5.9 to 6.2 mm: 4 cases (22.22 % of cases); 7 to 7.6 mm: 3 cases (16.67% of cases); 8.3-8.4 mm: 5 cases (27.28% of cases); 9.1 to 9.9 mm: 6 cases (33.33% of cases). Comparing the common iliac vein caliber of the two, right and left, we found that in 10 cases (55.56% of cases), the right internal iliac vein has a greater diameter than the left one by 0.3 mm. In 8 cases (44.44% of cases), the left internal iliac vein has a larger diameter than the right one with 0.1-0.6 mm; between the two values there is a difference of 0.5 mm


Sign in / Sign up

Export Citation Format

Share Document