scholarly journals Patient-specific instrumentation for total shoulder arthroplasty

2016 ◽  
Vol 1 (5) ◽  
pp. 177-182 ◽  
Author(s):  
Nuno Sampaio Gomes
2020 ◽  
pp. 175857322090890
Author(s):  
Robert Z Tashjian ◽  
Lindsay Beck ◽  
Irene Stertz ◽  
Peter N Chalmers

Background Computer assisted planning without patient specific instrumentation may be utilized to guide reverse total shoulder arthroplasty baseplate placement. The purpose of this study was to determine the difference between planned and achieved inclination and retroversion correction with three-dimensional preoperative computer assisted planning in reverse total shoulder arthroplasty without patient specific instrumentation with bone grafting for severe glenoid erosion. Methods Preoperative three-dimensional computer assisted planning without patient specific instrumentation was performed on 15 patients undergoing primary reverse total shoulder arthroplasty with glenoid bone grafting for severe glenoid erosion. On preoperative and immediate postoperative computed tomography slices, two-dimensional retroversion and inclination were measured. Preoperative three-dimensional baseline retroversion and inclination and planned postoperative three-dimensional retroversion and inclination were measured. Planned and achieved version and inclination changes were compared. Results The planned and achieved retroversion corrections were 18° and 12°, respectively (p < 0.001). The planned and achieved inclination corrections were 11° and 11°, respectively (p = 0.803). Conclusions Three-dimensional computer assisted planning without patient specific instrumentation in the setting of reverse total shoulder arthroplasty with severe glenoid erosion requiring bone grafting can accurately guide baseplate placement. All cases in which failure to correct retroversion or inclination within 10° of planning occurred in patients with severe erosion (B3 or E3 glenoids), therefore patient specific guides may be warranted in these cases to improve accuracy of implantation. Level of evidence Level IV, retrospective case series.


2019 ◽  
Vol 3 (2) ◽  
pp. 83-92 ◽  
Author(s):  
Brandon C. Cabarcas ◽  
Gregory L. Cvetanovich ◽  
Alejandro A. Espinoza Orías ◽  
Nozomu Inoue ◽  
Anirudh K. Gowd ◽  
...  

2018 ◽  
Vol 11 (2) ◽  
pp. 140-148 ◽  
Author(s):  
Alessandro Castagna ◽  
Raffaele Garofalo

Anatomic total shoulder arthroplasty (TSR) has been shown to generate good to excellent results for patients with osteoarthritis and a functioning rotator cuff. Many studies have reported that the glenoid component loosening and failure remain the most common long-term complication of total shoulder arthroplasty. The approach to glenoid component is critical because a surgeon should consider patient-specific anatomy, preserving bone stock and joint line restoration, for a good and durable shoulder function. Over the years, different glenoid design and materials have been tried in various configurations. These include cemented polyethylene, uncemented metal-backed and hybrid implants. Although advances in biomechanics, design and tribology have improved our understanding of the glenoid, the journey of the glenoid component in anatomic total shoulder arthroplasty has not yet reached its final destination. This article attempts to describe the evolution of the glenoid component in anatomic TSR and current practice.


Sign in / Sign up

Export Citation Format

Share Document