glenoid component
Recently Published Documents


TOTAL DOCUMENTS

298
(FIVE YEARS 72)

H-INDEX

44
(FIVE YEARS 3)

2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Maciej J. K. Simon ◽  
Jennifer A. Coghlan ◽  
Jeff Hughes ◽  
Warwick Wright ◽  
Richard J. Dallalana ◽  
...  

Abstract Background In an anatomic shoulder replacement (aTSR) good results have been reported with the use of a stemless humeral prosthesis. In vitro a ceramic articulation with polyethylene has been shown to produce less polyethylene wear particles than with metal. This study aims to evaluate clinical and radiographic results of a stemless aTSR with a ceramic head articulating with a polyethylene glenoid component, with mid-term follow-up. Methods All patients (n = 92) in this prospective study had an aTSR utilizing a stemless humeral component with a ceramic head and a cemented double pegged cemented polyethylene glenoid component for glenohumeral osteoarthritis. Pre- and postoperative clinical evaluations at 2 years were performed using the ASES score, Constant score, SPADI score, DASH score, VAS pain score, patient satisfaction and range of motion. There was a 5-year evaluation of SPADI, ASES, pain, and satisfaction, plus radiographic assessment of glenoid component radiolucent lines and humeral osteolysis. Results Seventy-four cases (68.1 ± 7.1 years) had a five-year follow-up and demonstrated active elevation improvement from 91.3° preoperatively to 151.1° (p < 0.001). Further improvement was identified with the ASES from 41.6 to 94.3, the SPADI from 62.9 to 4.3, VAS pain from 5.6 to 0.4 (0–10), and satisfaction levels were at 96%. Sixty-two cases had no glenoid radiolucent lines with a maximum Lazarus score of 2 in one patient. Constant scores, available up to 2 years, improved significantly from 30.3 to 77.9 (p < 0.001). There was one case that required revision for glenoid loosening. Conclusions Overall, the 5-year results of this ceramic head prosthesis demonstrated good radiographic and clinical outcomes. Trial registration ACTRN12613001183774. Registered: 29 October 2013 - Retrospectively registered. Australian New Zealand Clinical Trials Registry (ANZCTR).


Author(s):  
Kevin A. Hao ◽  
Christopher D. Sutton ◽  
Thomas W. Wright ◽  
Bradley S. Schoch ◽  
Jonathan O. Wright ◽  
...  

2022 ◽  
Vol 13 (1) ◽  
pp. 158-165
Author(s):  
R Azhagiri ◽  
M Anitha ◽  
J Hemapriya ◽  
Ganesan Murugaperumal ◽  
G Sumathi

Background: The morphology and morphometry of the scapula and its glenoid fossa and acromion process play a significant role in the mechanics of shoulder joint. A variable morphology is found in glenoid fossa that has clinical implications. Aims and Objectives: The aim of the study was to evaluate the morphology and morphometry of dry scapula with emphasis on glenoid fossa and acromion process. Materials and Methods: A cross-sectional study was conducted at the department of anatomy, for a period of 6 months from January 2021 to June 2021. A total of 100 unpaired dry scapula were included in the study. The morphology and dimensions were measured. The dimensions were summarized as mean and standard deviation. Statistical analysis was done Chi-square test and student’s t-test based on the variable types. Results: Out of 100 scapulae studied, 48 were right sided and 52 were left sided. The mean of maximum length of the right scapula was 149.58±10.33 mm and the left side was 148.63±10.33 mm. Among the glenoid cavities, 54 were inverted comma shaped, 30 were pear shaped, and 16 were oval shaped. In one right-sided scapula Bony Spur Extends from Base of coracoid process to supra Scapular Notch. Conclusion: Size and shape of the glenoid cavity are directly related to the dislocation of shoulder joint and may affect the results of total shoulder arthroplasty and rotator cuff surgeries. The present study analyzed the morphological types and diameters of the glenoid cavity in adult scapulae to improve the efficacy and minimize the failure rates in shoulder arthroplasty particularly those involving the glenoid component of the shoulder joint.


2021 ◽  
pp. 175857322110671
Author(s):  
Edoardo Franceschetti ◽  
Edoardo Giovannetti de Sanctis ◽  
Pietro Gregori ◽  
Michele Paciotti ◽  
Alessio Palumbo ◽  
...  

Background Two surgical techniques were compared : Standard BIO-RSA, performed with a glenoid eccentric reaming along with a cylindric bone graft augmentation vs. the Angled BIO-RSA, performed with a glenoid concentric reaming and a defect correction with an angled bone graft. Methods Patients undergoing RSA from January 2016 to April 2019, with one of the two techniques being performed, were retrospectively reviewed. Glenoids were classified according to Favard. Clinical (Constant-Murley, VAS and ROM) and radiographic (superior tilt correction) data were collected pre-operatively and at 12 months post-operatively. Results 141 shoulders were included. Angled BIO-RSA group showed statistically significant better outcomes in terms of forward flexion (149.9° Vs 139.3°) and abduction (136.4° Vs 126.7°). The use of an Angled BIO-RSA showed a statistically significant better superior tilt correction (1.252° Vs 4.09°). Angled BIO-RSA, leads to a better inclination correction and a mean postoperative tilt value inferior to 5° in E1 and E3 differently from standard BIO-RSA. Discussion Both techniques were able to correct glenoid superior inclination with excellent postoperative short-term results. However, angled BIO-RSA technique appears to be more effective in ensuring a correct inclination of the prosthetic glenoid component with better clinical outcomes.


2021 ◽  
Vol 10 (24) ◽  
pp. 5773
Author(s):  
Maciej J. K. Simon ◽  
Helen Crofts ◽  
Treny Sasyniuk ◽  
Kayla Johnston ◽  
Derek Plausinis ◽  
...  

Background: Malpositioning of the glenoid component in total shoulder arthroplasty (TSA) remains the primary source of loosening. The purpose of this study is firstly, to quantify postoperative glenoid component position in patients having a TSA and secondly, to explore whether glenoid component radiolucency is associated with glenoid position, clinical outcomes and patient-reported measures in the short-term (two year) follow-up period. Methods: This study was a sub-study of a larger clinical trial that included patients who underwent a TSA and who were randomized into two different glenoid types with a minimum two-year follow-up period. Post-operative radiographic assessments (six weeks and two years) were used to measure glenoid component position (version, inclination, offset) and humeral head centering anterior–posterior (AP) and superior–inferior (SI), and to assess glenoid component radiolucent scoring (modified Lazarus). Pre-operative X-rays were used to measure glenoid version, inclination and Walch classification. Patient-reported measures (PROMs) included the EQ-5D health slider and the Western Ontario Osteoarthritis (WOOS) and American Shoulder and Elbow Surgeons (ASES) score and were captured at baseline and two years postoperative. Clinical outcomes including range of motion and complications were also documented. Statistical analysis included t-tests and regression modeling. Results: Ninety-one patients with an average age of 69.9 ± 6.2 years were included in this study. Glenoid component position improved significantly in version (−19.4 ± 8.6° to −17.7 ± 8.5°; p < 0.045) and inclination (11.5 ± 7.1° to 5.9 ± 6.3°; p < 0.00001) from preoperative to six weeks postoperative. Glenoid component offset in SI and humeral head centering in AP remained unchanged throughout the follow-up. Radiolucency (Lazarus classification) was recorded in 21 cases (17.3%) with a Lazarus score of 1 (15 cases) and 2 (6 cases). The EQ-5D health slider, WOOS and ASES, and ROM confirmed continuous improvements from the preoperative scores to the two-year follow-up (p < 0.05). Regression models showed no correlation between glenoid component radiolucency at two years and the postoperative week six glenoid component position; however, female gender was a significant variable. Conclusion: Glenoid component changes from its original native glenoid were observed following TSA. Glenoid inclination was improved more than version from baseline, and the humeral head remained well-centered in AP and SI at two years. Radiolucency of the glenoid at two years is not negatively associated with PROMs or component position; however, female gender was identified as a significant predictor and warrants further investigation. Complications are not associated with glenoid position or radiolucency, but longer-term follow-up is required.


2021 ◽  
pp. 155633162110408
Author(s):  
Ahmed Haleem ◽  
Phelopater Sedrak ◽  
Chetan Gohal ◽  
George S. Athwal ◽  
Moin Khan ◽  
...  

Background: Hybrid glenoid components in total shoulder arthroplasty (TSA) utilize both polyethylene and metal components to provide short-term stability and long-term biologic fixation through bone ingrowth. Questions/Purpose: We sought to systematically review the literature for studies that assessed outcomes of TSA performed using hybrid glenoid components. Methods: PubMed, Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Embase were searched systematically for articles measuring clinical and patient-reported outcomes and rates of complication and revision following TSA using a hybrid glenoid component. Results: Seven studies with 593 shoulders were included in this review. The mean age of patients was 65 ± 1 years, and 46% of the population was male. Mean follow-up was 50 months (4.2 years). The overall complication rate was 7% and rate of revision was 2.5%; glenoid radiolucency was present in 33% of shoulders at mean follow-up of 50 months. Mean improvements in forward elevation, external rotation, internal rotation score, and abduction were 49°, 28°, 2 points, and 42°, respectively. Mean improvements in Constant, American Shoulder and Elbow Surgeons (ASES), and University of California, Los Angeles (UCLA) scores were 36 points, 52 points, and 17 points, respectively. Conclusion: Our review found that TSA using hybrid glenoid components results in low rates of complication and revision at early follow-up. Long-term studies are warranted to understand more fully the role of hybrid glenoid components in TSA.


Sign in / Sign up

Export Citation Format

Share Document