Atraumatic Index Finger Flexor Tendon Rupture as a Presenting Sign of Capitate Osteonecrosis

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Viviana M. Serra López ◽  
Joseph Koressel ◽  
Stephen Y. Liu ◽  
David Steinberg
2019 ◽  
Vol 2019 ◽  
pp. 1-4
Author(s):  
Akira Hashimoto ◽  
Motoki Sonohata ◽  
Hideyuki Senba ◽  
Masaaki Mawatari

Spontaneous flexor tendon rupture is rare, occurring most commonly in the little finger or flexor pollicis longus. To the best of our knowledge, there have been no reports of spontaneous flexor tendon rupture due to primary distal radioulnar joint (DRUJ) osteoarthritis (OA). We present a case of spontaneous flexor tendon rupture in the index finger due to primary DRUJ OA in a 71-year-old female farmer. Surgical exploration confirmed that, at the wrist joint level, the flexor digitorum profundus of the index finger had undergone degeneration and complete rupture. The flexor digitorum superficialis of the index finger was elongated and thinned. A bony spur toward the volar side was covered with synovial fluid from a pinhole-sized perforation of the capsule. The combination of direct friction from the DRUJ spur and the matrix metalloproteinases in the synovial fluid from the perforation of the DRUJ capsule may have caused the spontaneous flexor tendon rupture. Palmar-side symptoms associated with DRUJ OA should be carefully examined because of the risk of spontaneous flexor tendon rupture.


2019 ◽  
Vol 27 (3) ◽  
pp. 230949901988637
Author(s):  
Koichi Yano ◽  
Yasunori Kaneshiro ◽  
Masuhiro Tomita ◽  
Yusuke Miyashima ◽  
Hirohisa Yagi ◽  
...  

Flexor tendon rupture in the wrist of patients with rheumatoid arthritis is a rare complication, and there is no standard treatment for the wrist joint. Here, we present the case of a rupture of the flexor digitorum profundus of the left index finger owing to a rheumatoid wrist. Plain radiography and computed tomography showed carpal collapse, especially lunate, and arthrosis between the capitate and lunate. For stability and mobility of the wrist and index finger, resection of the lunate and radiotriquetral (RT) arthrodesis using the distal ulna as a bone graft and arthrodesis of the distal interphalangeal joint of the index finger were performed. At 2 years postoperatively, her wrist was painless and stable on radiography without recurrence of tendon rupture, and the arc of motion of the dorsal-palmar flexion of the wrist joint was 125°. RT arthrodesis could be a surgical choice of “mobile” partial wrist arthrodesis.


2021 ◽  
Vol 17 (2) ◽  
pp. 146-149
Author(s):  
Hyun-Dong Yeo ◽  
Na-Hyun Hwang ◽  
Seung-Ha Park ◽  
Byung-Il Lee ◽  
Eul-Sik Yoon ◽  
...  

We report the case of a patient who fully recovered from a closed flexor tendon rupture through a two-stage flexor tendon reconstruction using silicone rods, despite a considerable delay in treatment. A 17-year-old male patient visited our clinic with a sudden inability to flex his left index finger, although there were no signs of injury. Magnetic resonance imaging revealed an extensive rupture of the flexor digitorum profundus from the base of the distal phalanx to the proximal phalangeal joint of his left hand. After a two-stage tendon graft operation was performed, the patient regained full flexion of the index finger and was able to hold a fist without any limitations in range of motion. Complete rupture of tendons usually accompanies history of trauma or underlying tendon pathology. In our case, however, the tendon rupture occurred silently with no obvious underlying causes. It is important to recognize the signs to evaluate the underlying structures for appropriate management and treatment. Even with considerable delay, the patient may regain full function of the tendon.


2014 ◽  
Vol 26 (5) ◽  
pp. 794-797 ◽  
Author(s):  
Ryo Oda ◽  
Hiroyoshi Fujiwara ◽  
Daisaku Tokunaga ◽  
Aiko Kishida ◽  
Daigo Taniguchi ◽  
...  

2020 ◽  
Vol 25 (04) ◽  
pp. 481-488
Author(s):  
Rui Hirasawa ◽  
Eichi Itadera ◽  
Seiji Okamoto

Background: Flexor tendon rupture is a major complication after volar locking plating for distal radius fracture (DRF). Few studies have investigated changes in the rate of postoperative flexor tendon rupture in patients with DRFs. The present study aimed to investigate the changes in the rate of postoperative flexor tendon rupture and to assess plate placement and reduction positions. Methods: We retrospectively reviewed patients in whom more than 24 months had passed since DRF surgery. The patients were interviewed by telephone. Forty-nine patients (50 fractures; 2007–2009) from institution A were included in group 1 and 81 patients (84 fractures; 2013–2016) from institution B were included in group 2. The DRF surgery method was similar between the two groups. The rate of flexor tendon rupture, Soong classification grade, and radiological index (i.e., volar tilt [VT], radial inclination [RI], and ulnar variance [UV]) were statistically investigated in both groups. Results: Patient epidemiology was not significantly different between the two groups. The flexor tendon rupture rates were 2% and 0% in groups 1 and 2, respectively, without a significant difference. With regard to the Soong grade, 44 fractures were grade 2 and 6 were grade 1 in group 1, whereas 18 were grade 2, 38 were grade 1, and 28 were grade 0 in group 2, with a significant difference (p < 0.05). With regard to the radiological index, the mean VT values were 5° and 11° in groups 1 and 2, respectively, with a significant difference (p < 0.05). However, RI and UV showed no significant difference. Conclusions: Plate placement and reduction positions, which are risk factors for flexor tendon ruptures after DRFs, have improved recently when compared with previous findings. With these changes, the rate of flexor tendon rupture is presumed to have decreased.


Author(s):  
David Warwick ◽  
Roderick Dunn ◽  
Erman Melikyan ◽  
Jane Vadher

Anatomy and physiology 392Tendon healing 394Flexor tendon anatomy 396Flexor tendon zones of injury 400Flexor tendon suture techniques 402Flexor tendon repair 404Closed flexor tendon rupture 410Flexor tenolysis 412Flexor tendon reconstruction 414Extensor tendon anatomy 418Extensor tendon repair ...


Hand Surgery ◽  
2006 ◽  
Vol 11 (01n02) ◽  
pp. 67-70 ◽  
Author(s):  
Siu Cheong Koo ◽  
Sheung Tung Ho

Flexor tendon rupture following distal radius fracture is rare. We described a case of flexor pollicis longus rupture, presented five years after volar plating of distal radius fracture.


1988 ◽  
Vol 13 (1) ◽  
pp. 115-119 ◽  
Author(s):  
Steven A. Lillmars ◽  
David C. Bush

1991 ◽  
Vol 16 (4) ◽  
pp. 663-665 ◽  
Author(s):  
W.K. de Roos ◽  
R.J. Zeeman

Sign in / Sign up

Export Citation Format

Share Document