Implementation of chevrons as a noise reduction system for a supersonic tactical nozzle

2022 ◽  
Author(s):  
Omar Lopez Rodriguez ◽  
Mohammad Saleem ◽  
Ephraim J. Gutmark ◽  
Junhui Liu
2020 ◽  
Author(s):  
Lieber Po-Hung Li ◽  
Ji-Yan Han ◽  
Wei-Zhong Zheng ◽  
Ren-Jie Huang ◽  
Ying-Hui Lai

BACKGROUND The cochlear implant technology is a well-known approach to help deaf patients hear speech again. It can improve speech intelligibility in quiet conditions; however, it still has room for improvement in noisy conditions. More recently, it has been proven that deep learning–based noise reduction (NR), such as noise classification and deep denoising autoencoder (NC+DDAE), can benefit the intelligibility performance of patients with cochlear implants compared to classical noise reduction algorithms. OBJECTIVE Following the successful implementation of the NC+DDAE model in our previous study, this study aimed to (1) propose an advanced noise reduction system using knowledge transfer technology, called NC+DDAE_T, (2) examine the proposed NC+DDAE_T noise reduction system using objective evaluations and subjective listening tests, and (3) investigate which layer substitution of the knowledge transfer technology in the NC+DDAE_T noise reduction system provides the best outcome. METHODS The knowledge transfer technology was adopted to reduce the number of parameters of the NC+DDAE_T compared with the NC+DDAE. We investigated which layer should be substituted using short-time objective intelligibility (STOI) and perceptual evaluation of speech quality (PESQ) scores, as well as t-distributed stochastic neighbor embedding to visualize the features in each model layer. Moreover, we enrolled ten cochlear implant users for listening tests to evaluate the benefits of the newly developed NC+DDAE_T. RESULTS The experimental results showed that substituting the middle layer (ie, the second layer in this study) of the noise-independent DDAE (NI-DDAE) model achieved the best performance gain regarding STOI and PESQ scores. Therefore, the parameters of layer three in the NI-DDAE were chosen to be replaced, thereby establishing the NC+DDAE_T. Both objective and listening test results showed that the proposed NC+DDAE_T noise reduction system achieved similar performances compared with the previous NC+DDAE in several noisy test conditions. However, the proposed NC+DDAE_T only needs a quarter of the number of parameters compared to the NC+DDAE. CONCLUSIONS This study demonstrated that knowledge transfer technology can help to reduce the number of parameters in an NC+DDAE while keeping similar performance rates. This suggests that the proposed NC+DDAE_T model may reduce the implementation costs of this noise reduction system and provide more benefits for cochlear implant users.


1992 ◽  
Vol 91 (5) ◽  
pp. 3085-3085
Author(s):  
Edwin Langberg ◽  
F. Gerald Caruso

2007 ◽  
Vol 121 (4) ◽  
pp. 1839
Author(s):  
William Richard Saunders ◽  
Michael Allen Vaudrey

1996 ◽  
Vol 99 (1) ◽  
pp. 18
Author(s):  
Jin Yang ◽  
Andrew Sendyk

Sign in / Sign up

Export Citation Format

Share Document