scholarly journals Rapid detection of avian leukosis virus using a fluorescent microsphere immunochromatographic test strip assay

2019 ◽  
Vol 98 (12) ◽  
pp. 6492-6496 ◽  
Author(s):  
Huanan Wang ◽  
Jianchi Guan ◽  
Xiangnan Liu ◽  
Yue Shi ◽  
Qiwen Wu ◽  
...  
2018 ◽  
Vol 29 (1) ◽  
pp. 1126-1136 ◽  
Author(s):  
Wenliang Ge ◽  
Steven Suryoprabowo ◽  
Liguang Xu ◽  
Qiankun Zheng ◽  
Hua Kuang

2017 ◽  
Vol 28 (3) ◽  
pp. 427-438 ◽  
Author(s):  
Liqiang Liu ◽  
Steven Suryoprabowo ◽  
Qiankun Zheng ◽  
Shanshan Song ◽  
Hua Kuang

2015 ◽  
Vol 2 (1) ◽  
Author(s):  
Hesong Liu ◽  
Yue Wang ◽  
Jingfan Xiao ◽  
Qiyao Wang ◽  
Qin Liu ◽  
...  

2017 ◽  
Vol 32 (4) ◽  
pp. 335-337
Author(s):  
Dongyang Fan ◽  
Jingwen Liu ◽  
Miaomiao Xu ◽  
Yangyang Yuan ◽  
Jifang Yang ◽  
...  

2018 ◽  
Vol 29 (1) ◽  
pp. 821-832 ◽  
Author(s):  
Min Feng ◽  
Steven Suryoprabowo ◽  
Hong Tao ◽  
Liqiang Liu ◽  
Qiankun Zheng ◽  
...  

2017 ◽  
Vol 29 (1) ◽  
pp. 498-510 ◽  
Author(s):  
Kai Hao ◽  
Steven Suryoprabowo ◽  
Shanshan Song ◽  
Liqiang Liu ◽  
Hua Kuang

Author(s):  
Chunyan Zhang ◽  
Lei Zhou ◽  
Kang Du ◽  
Ying Zhang ◽  
Jing Wang ◽  
...  

PurposeTo develop a rapid detection reagent for SARS-CoV-2 antigen for the auxiliary diagnosis of new coronary pneumonia (COVID-19), and perform the methodological evaluation and clinical evaluation of the reagent.MethodSARS-CoV-2 N-protein test strip was created by combining fluorescent microsphere labeling technology and immunochromatographic technology, based on the principle of double antibody sandwich. Then we evaluated the analytical capability and clinical application of the strips.ResultThe limit of detection of the strips for recombinant N protein was 100 ng/ml and for activated SARS -CoV-2 virus was 1 × 103 TCID50/ml. The strips also have high analytical specificity and anti-interference capability. According to the predetermined cut-off value, the specificity of the test strip in healthy controls and patients with other respiratory disease was 100.00 and 97.29%, the sensitivity in COVID-19 cases at progress stage and cured stage was 67.15 and 7.02%. The positive percentage agreement and negative percentage agreement of antigen strip to RNA test were 83.16 and 94.45%.ConclusionSARS-CoV-2 fluorescence immunochromatographic test strip can achieve fast, sensitive and accurate detection, which can meet the clinical requirements for rapid detection of viruses on the spot.


2020 ◽  
Vol 14 (9) ◽  
pp. e0008557
Author(s):  
Guangqiang Li ◽  
Zhen Rong ◽  
Shengqi Wang ◽  
Hongyan Zhao ◽  
Dongri Piao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document