scholarly journals Review of Bone Conduction Hearing Devices

2021 ◽  
Vol 11 (2) ◽  
pp. 207-219
Author(s):  
Susan E. Ellsperman ◽  
Emily M. Nairn ◽  
Emily Z. Stucken

Bone conduction is an efficient pathway of sound transmission which can be harnessed to provide hearing amplification. Bone conduction hearing devices may be indicated when ear canal pathology precludes the use of a conventional hearing aid, as well as in cases of single-sided deafness. Several different technologies exist which transmit sound via bone conduction. Here, we will review the physiology of bone conduction, the indications for bone conduction amplification, and the specifics of currently available devices.

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Joseph T. Breen ◽  
Marc-Elie Nader ◽  
Paul W. Gidley

2021 ◽  
Vol 32 (07) ◽  
pp. 395-404
Author(s):  
Adam Voss ◽  
Alison Brockmeyer ◽  
Michael Valente ◽  
John Pumford ◽  
Cameron C. Wick ◽  
...  

Abstract Background Best practice guidelines for verifying fittings of bone-anchored hearing devices (BAHD) recommend using aided sound-field thresholds (ASFT), but express caution regarding the variables impacting obtaining valid and reliable ASFTs.1 Recently, a skull simulator was introduced to facilitate programming BAHD devices in force level (FL) to desired sensation level-bone conduction devices (skull simulator/DSL-BCD)2 3 targets in a hearing aid analyzer. Currently, no evidence is available reporting if differences in measured FL using the manufacturer first-fit (FF) and word recognition in quiet, sentence reception threshold in noise, and subjective outcomes are present for a BAHD programmed using ASFT versus programmed using skull simulator/DSL-BCD targets. Purpose The aim of this study was to examine if significant differences were present in FL using the FF and word recognition in quiet at 50 and 65 decibel of sound pressure level (dB SPL), sentence reception threshold in noise and subjective outcomes using the abbreviated profile of hearing aid benefit (APHAB), and speech, spatial, and qualities of hearing (SSQ) between a BAHD fit using ASFT or skull simulator/DSL-BCD targets. Research Design A double-blind randomized crossover design with 15 adults having unilateral sensorineural hearing loss. All participants were successful users of the Cochlear America Baha 5. Data Collection and Analysis Baha Power 5 devices were fit using FF, ASFT, and skull simulator/DSL-BCD targets. Order of the three fitting strategies was randomly assigned and counter-balanced. Results No significant differences were found for a BAHD device programmed using ASFT versus skull simulator/DSL-BCD targets for consonant-nucleus-consonant words in quiet at 50 or 65 dB SPL, sentence reception threshold in noise, the APHAB or SSQ. There were, however, significant differences, at primarily 500 to 2,000 Hz in measured FLs between the FF, ASFT, and skull simulator/DSL-BCD targets at 50 and 65 dB SPL. Conclusions There were no significant differences in subject performance with two speech measures and subjective responses to two questionnaires for BAHD fittings using ASFT versus using skull simulator/DSL-BCD targets. Differences in FL between the three fitting strategies were present primarily at 500 to 2,000 Hz. Limitations of the study are highlighted along with situations where the skull simulator can play a significantly beneficial role when fitting BAHD devices.


1986 ◽  
Vol 94 (4) ◽  
pp. 421-426 ◽  
Author(s):  
Peder Carlsson ◽  
Bo Håkansson ◽  
Ulf Rosenhall ◽  
Anders Tjellström

Hitherto, for persons with impaired hearing who cannot use an air conduction hearing aid, the only alternative has been a conventional spring-loaded bone conduction hearing aid. Now, with minor surgery, a titanium screw can be implanted in the bone behind the ear and a coupling, which penetrates the skin, can be attached, giving a new kind of hearing aid—the “bone-anchored hearing aid.” Improved quality of sound is one of the patients’ subjective assessments. Improvement was not confirmed by a standard speech-discrimination test. With new speech material consisting of sentences in noise, the speech-to-noise ratio (SN) has been determined for 24 patients. Patients who previously used a conventional bone conduction hearing aid improved their SN on the average by 3.3 dB. The most important difference between the two aids related to improved SN is probably the increased audibility between 600 and 6000 Hz.


2008 ◽  
Vol 30 (2) ◽  
pp. 113-118
Author(s):  
George Raicevich ◽  
Eric Burwood ◽  
Harvey Dillon