Faculty Opinions recommendation of Three-dimensional color Doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success.

Author(s):  
Rebecca Hahn
2014 ◽  
Vol 27 (11) ◽  
pp. 1153-1163 ◽  
Author(s):  
Eduardo Franco ◽  
Carlos Almería ◽  
Jose Alberto de Agustín ◽  
Viviana Arreo del Val ◽  
José Juan Gómez de Diego ◽  
...  

Author(s):  
Gentil Barreira de Aguiar Filho ◽  
Guilhermo Guerra Guimarães ◽  
Leonardo Mello Guimarães de Toledo ◽  
David Costa de Souza Le Bihan ◽  
Sergio Luiz Navarro Braga ◽  
...  

2020 ◽  
Vol 4 (3) ◽  
pp. 1-6
Author(s):  
Reda Abuelatta ◽  
Lamiaa Khedr ◽  
Ibraheem AlHarbi ◽  
Hesham A Naeim

Abstract Background Haemolytic anaemia is a complication of paravalvular leak (PVL). The correlation between the size of the leak and the severity of haemolysis is unclear. Small leaks can cause severe haemolysis, whereas significant leaks may cause no haemolysis. Case summary We report the case of a 40-year-old male who underwent mechanical mitral and aortic valve replacement 20 years ago. In the last 3 years, the procedure was repeated three times due to infective endocarditis. He presented with severe shortness of breath. A transoesophageal echocardiogram with three-dimensional surgical view showed that both discs of the mechanical mitral valve opened sufficiently but a severe PVL had occurred at the 9–12 o’clock position. The location of the mitral valve was abnormal, the sewing ring was inserted high at the mid-interatrial septum. The mechanical aortic valve functioned well. Closure of the transcutaneous PVL was accomplished with two percutaneously implanted devices, leaving a small leak in between. After closure, he developed haemolytic anaemia (haemoglobin: 6 g/dL, lactate dehydrogenase: 1896 units/L, reticulocyte count: 4.6%). He then received 16 units of packed red blood cells. He developed acute kidney injury and was started on haemodialysis. We then installed two additional devices to completely close the mild residual leak and another device to resolve the bidirectional transseptal defect. After 2 days, his renal function returned to normal and anaemia improved (haemoglobin: 9.1 g/dL). Discussion Mild residual paravalvular leak can cause severe haemolytic anaemia that is correctable via percutaneous closure of the leak.


Author(s):  
Rodrigo Tobias Giffoni ◽  
Gustavo Nishida ◽  
Guilherme Barreto Gameiro Silva ◽  
David Costa de Souza Le Bihan ◽  
Rodrigo Bellio de Mattos Barretto ◽  
...  

2013 ◽  
Vol 62 (18) ◽  
pp. B214 ◽  
Author(s):  
Takashi Matsumoto ◽  
Jun Tanaka ◽  
Wen Loong Yeow ◽  
Asma Hussaini ◽  
Mamoo Nakamura ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document