Vertical Electrical Soundings for Groundwater Assessment in Southeastern Iran: A Case Study

2005 ◽  
Vol 5 (6) ◽  
pp. 973-977 ◽  
Author(s):  
G.R. Lashkaripo ◽  
H. Sadeghi . ◽  
M. Qushaeei .
2016 ◽  
Author(s):  
Alejandro Villalobos-Aragon ◽  
◽  
Vanessa Veronica Espejel-Garcia ◽  
Lucio Rivas-Lobera ◽  
Irianyt Gonzalez-Rojas ◽  
...  

2016 ◽  
Vol 33 (3) ◽  
Author(s):  
Eduardo M.S. Amarante ◽  
Olivar A.L. de Lima ◽  
Susana S. Cavalcanti

ABSTRACT. To investigate the subsurface geological and hydrological conditions around the area of the Alagoinhas county cemetery – Bahia State, Brazil, 38 vertical electrical soundings using Schlumberger electrode array were performed to a maximum AB/2 spacing... RESUMO. Para investigar as condições geológicas e hidrológicas da subsuperfície na área do entorno do Cemitério Municipal de Alagoinhas, Bahia, foram realizadas 38 sondagens elétricas verticais centradas em pontos acessíveis da área. As sondagens foram...


Geophysics ◽  
1980 ◽  
Vol 45 (7) ◽  
pp. 1205-1208
Author(s):  
B. B. Bhattacharya ◽  
P. K. Hazra

In this paper, the authors showed a series of electromagnetic (EM) profiles (Figure 20, p. 86) obtained from the ground follow‐up using a slingram system with a frequency of 1600 Hz and coil separation of 120 m. Measurements along all the profiles (A to E) show considerable in‐phase and quadrature anomaly. The host rock in this case is amphibolite. The vertical electrical soundings over the amphibolite (Figure 16, p. 82) indicate that the weathered amphibolite has mean thickness and resistivity of 8.5 ± 2.1 m and 29.7 ± 6.5 Ω-m, respectively. It would, therefore, be reasonable to assume that the in‐phase and quadrature anomalies have been influenced due to the presence of conducting overburden, and the response of the target in such a situation can be altogether different compared to the anomaly of the target in the presence of an insulating or highly resistive overburden.


2021 ◽  
Vol 4 (4) ◽  
pp. 547-560
Author(s):  
Aniefiok Akpaneno ◽  
S. Abdulwahab

A geophysical investigation involving Vertical Electrical Sounding (VES) using the Schlumberger array was carried out at the Isa Kaita College of Education specifically at the Male Hostel. The aim of the investigation is to explore the groundwater contamination of the area with the objectives: to determine the depth to basement of the study area, to determine the aquifer thickness, to determine the depth to aquifer, to determine the conductivity of the aquifer and to determine the thickness of topsoil and its variation in resistivity. A total of four (4) vertical electrical soundings were carried out using Schlumberger configuration. Terrameter signal averaging system (SAS) model 300 was the instrument used. The survey area is dominated by mainly four layers, namely: Topsoil, Weathered basement, fractured basement. The value of VES 03 and VES 04 have high electrical conductivities which likely shows they are contaminated, The topsoil resistivity along the profile ranges from approximately 1 to 154, The depth to basement (basement topography) Varies from 4.94 m to 7.59 m, The thickness of aquifer range from  1 m to 6.8 m.  Therefore VES 02 has high Potential for groundwater because it has retaining capacity and good aquifer thickness and is therefore recommended for borehole establishment. It is recommended that the management of Isa Kaita College of Education should provide a concrete dumping site to avoid leaching of waste in ground thereby contaminating the groundwater.


Sign in / Sign up

Export Citation Format

Share Document