scholarly journals THE HOT WATER DISTRIBUTION SYSTEMS ANALYSIS FROM HEAT LOSSES POINT OF VIEW

Author(s):  
Kapalo Peter
Author(s):  
Luna Girolamini ◽  
Silvano Salaris ◽  
Jessica Lizzadro ◽  
Marta Mazzotta ◽  
Maria Rosaria Pascale ◽  
...  

In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and formulate appropriate preventive measures. Hot water samples were cultured according to ISO 11731:2017. The isolates were serotyped using an agglutination test and genotyped by sequence-based typing (SBT) for Legionella pneumophila or macrophage infectivity potentiator (mip) gene sequencing for non-pneumophila Legionella species. The isolates’ relationship was phylogenetically analyzed. The Legionella distribution and level of contamination were studied in relation to temperature and disinfectant residues. The culture technique detected 62.21% of Legionella positive samples, characterized by L. pneumophila serogroup 1, Legionella non-pneumophila, or both simultaneously. The SBT assigned two sequence types (STs): ST1, the most prevalent in Italy, and ST104, which had never been isolated before. The mip gene sequencing detected L. anisa and L. rubrilucens. The phylogenetic analysis showed distinct clusters for each species. The distribution of Legionella isolates showed significant differences between buildings, with a negative correlation between the measured level of contamination, disinfectant, and temperature. The Legionella molecular approach introduced in HWDSs environmental surveillance permits (i) a risk map to be outlined that can help formulate appropriate disinfection strategies and (ii) rapid epidemiological investigations to quickly identify the source of Legionella infections.


2015 ◽  
Vol 71 ◽  
pp. 244-256 ◽  
Author(s):  
Emilie Bédard ◽  
Stéphanie Fey ◽  
Dominique Charron ◽  
Cindy Lalancette ◽  
Philippe Cantin ◽  
...  

Author(s):  
Edward W. Saltzberg

Our Office Had Two Condominium Litigation Cases That Had A Number Of Construction Defects. One Was A Luxury Complex And One Was A Moderately Priced Project. However, There Were Two Common Allegations In Both Cases. These Allegations Were That The Occupants Complained That They Did Not Have Sufficient Hot Water And That The Water Heater Was Not Able To Provide A Sufficient Quantity Of Hot Water. We Prepared Calculations On Both Of The Water Heater Systems To Determine If They Were Undersized. The Calculations Determined That The Water Heater Assembly Of Both Installations Were Liberally Sized And Should Have Been Able To Maintain Design Temperature All The Time, Even At Peak Use. To Ensure That The Water Heaters Were Both Operating Correctly, We Had The Water Heater Manufacturer Come Out And Service The Heaters On Both Systems. Both Systems Were Operating Properly.


Sign in / Sign up

Export Citation Format

Share Document