CoreValve bioprosthesis dysfunction treated with a Sapien 3 valve‐in‐valve transcatheter aortic valve replacement and BASILICA technique

Author(s):  
Ravi K Sharma ◽  
Mark K Tuttle ◽  
Marie‐France Poulin ◽  
Roger J Laham
2021 ◽  
Vol 14 (2) ◽  
pp. 211-220 ◽  
Author(s):  
Michel Pompeu B.O. Sá ◽  
Jef Van den Eynde ◽  
Matheus Simonato ◽  
Luiz Rafael P. Cavalcanti ◽  
Ilias P. Doulamis ◽  
...  

2021 ◽  
Vol 5 (5) ◽  
Author(s):  
Klaus-Dieter Hönemann ◽  
Steffen Hofmann ◽  
Frank Ritter ◽  
Gerold Mönnig

Abstract Background A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). Case summary We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. Discussion We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.


Author(s):  
Tamim M. Nazif ◽  
Thomas J. Cahill ◽  
David Daniels ◽  
James M. McCabe ◽  
Mark Reisman ◽  
...  

Background: Paravalvular regurgitation (PVR) after transcatheter aortic valve replacement is associated with adverse clinical outcomes. The SAPIEN 3 Ultra (Ultra) is a new generation balloon-expandable transcatheter heart valve with a modified external skirt that is designed to reduce PVR, but reports of clinical and echocardiographic outcomes are limited. The aim of this study was to compare short-term outcomes of patients undergoing transcatheter aortic valve replacement with the Ultra and the original SAPIEN 3 (S3) transcatheter heart valve in a large national registry. Methods: Data from The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry was used to compare patients who underwent elective, transfemoral transcatheter aortic valve replacement with the Ultra or S3 transcatheter heart valve. Clinical and echocardiographic outcomes were analyzed in a propensity-matched cohort at discharge and 30 days. Results: Patients who underwent transcatheter aortic valve replacement with Ultra (N=1324) from January 2019 to February 2020 were propensity score–matched with patients treated with S3 (N=32 982) during the same period, resulting in 1324 matched pairs. There was no difference in the rate of device success between patients treated with Ultra and S3 (97.1% versus 98.0%, P =0.11). At hospital discharge, PVR was significantly reduced with Ultra compared with S3, with mild PVR in 9.0% versus 13.9% and moderate or greater PVR in 0.1% versus 0.4% (overall P <0.01). At 30 days, there were no differences between Ultra and S3 recipients in the rates of all-cause mortality or stroke (1.8% versus 2.8%, P =0.10), major vascular complications (1.1% versus 1.0%, P =0.84), or permanent pacemaker implantation (6.4% versus 6.2%, P =0.81). Conclusions: In this propensity-matched analysis from the Transcatheter Valve Therapy Registry, the Ultra transcatheter heart valve was associated with similar procedural and 30-day clinical outcomes, but reduced incidence of PVR, compared with S3. The clinical benefit of less PVR should be evaluated in longer-term studies.


Author(s):  
Tom C. Nguyen ◽  
Alexander P. Nissen ◽  
Pranav Loyalka ◽  
Eyal E. Porat

Reoperative aortic valve replacement is associated with increased morbidity. Valve-in-valve transcatheter aortic valve replacement offers a less invasive alternative to traditional reoperation. However, cases of valve failure after valve-in-valve transcatheter aortic valve replacement represent a complex surgical challenge. We present a case requiring a complex reoperative aortic valve replacement due to structural valve deterioration after multiple previous valve-in-valve transcatheter aortic valve replacements. We performed removal of 3 previous valve-in-valve transcatheter aortic valves, bioprosthetic leaflet excision, and intentional bioprosthetic fracture under direct vision for annular enlargement. This facilitated direct insertion of a new transcatheter aortic valve for expedient and successful management of recurrent aortic stenosis in a very high-risk patient. Creative use of leaflet excision, intentional bioprosthetic fracture, and insertion of a new transcatheter aortic valve under direct vision, proved efficient and successful in a high-risk patient with few surgical options.