IEC 61508 — A Suitable Basis for the Certification of Safety-Critical Transport-Infrastructure Systems ??

Author(s):  
Derek Fowler ◽  
Phil Bennett
Author(s):  
Vyacheslav Kharchenko ◽  
Oleg Odarushchenko ◽  
Vladimir Sklyar ◽  
Alexandr Ivasyuk

Features of verification FPGA-based safety critical I&C systems (FBIC) using of fault-insertion technique (FIT) are analyzed. The FIT is applied in process of certification to meet requirements of IEC 61508 according with safety integrity level (SIL). Specific aspects of FBIC SIL-certification are described. Concept of FIT-ability, theoretical issues and optimal FIT procedure taking into account different points and means of fault insertion are offered. The developed technique and tool to verify FPGA-based platform RadICS using FIT procedure during SIL-certification are described.


2021 ◽  
Author(s):  
Fabrizio D'Amico ◽  
Valerio Gagliardi ◽  
Chiara Clementini ◽  
Daniele Latini ◽  
Fabio Del Frate ◽  
...  

<p>Bridges and viaducts are exposed to a variety of threats that can affect their operations and structural integrity [1]. Recent unexpected collapses and failures of bridges underline the need for effective structural monitoring, particularly for reinforced concrete structures. In fact, once distress mechanisms are triggered, these can deteriorate faster than the time required for rehabilitation, strengthening, or replacement.</p><p>To this extent, it is evident that the monitoring of the actual health conditions of the existing bridges is a priority for asset operators in order to guarantee the structural integrity, the safety of the operations and preventing irreversible damages or even structural collapses.</p><p>Within this context, Non-Destructive Testing (NDT) methods such as Ground Penetrating Radar (GPR) and Terrestrial Laser Scanner (TLS) amongst many others have been used for the assessing and monitoring such structures in the past few years[2]. However, topic-related studies [3-4] have demonstrated that stand-alone use of ground-based techniques may not represent a definitive solution to particular major structural issues, such as scour and differential settlements, as these require continuous monitoring and data collection on long-term bases . To that extent, the use of satellite-based remote sensing techniques, such as Synthetic Aperture Radar Interferometry (InSAR), have proven to be effective in detecting displacements with a millimetre accuracy along with transport infrastructures [3-5] and natural terrain considering long periods of observation.</p><p>Accordingly, this research aims to present a novel integrated monitoring approach including the use of ground-based technologies (GPR, TLS) and the InSAR techniques over a Maillart arch type bridge: the Viadotto Olivieri in Salerno, (in the South of Italy).</p><p>Main objectives of the research  are: (1) to prove the viability of low-frequency and high-frequency GPR systems in providing structural detailing of the bridge-deck at different depths and resolutions; (2) to measure seasonal structural displacements with a millimetre accuracy to detect potential critical issues of the bridge.</p><p>The outcomes of this study, under the National Project “EXTRA TN”, PRIN 2017- Prot. 20179BP4SM, demonstrate how multi-temporal InSAR remote sensing techniques can be synergistically applied to complement the traditional ground-based surveys.</p><p> </p><p>References</p><p>[1] Hosseini Nourzad, S. H. and Pradhan, A. Vulnerability of Infrastructure Systems: Macroscopic Analysis of Critical Disruptions on Road Networks. Journal of Infrastructure Systems, 22(1), 04015014. 2016</p><p>[2] D’Aranno, P., Di Benedetto, A., Fiani, M., and Marsella, M.: Remote Sensing Technologies For Linear Infrastructure Monitoring, Int. Arch. Photogramm. Remote Sens. Spatial Inf. Sci., XLII-2/W11, 461–468, https://doi.org/10.5194/isprs-archives-XLII-2-W11-461-2019, 2019.</p><p>[3] Bianchini Ciampoli, L., Gagliardi, V., Clementini, et al., Transport Infrastructure Monitoring by InSAR and GPR Data Fusion. Surv Geophys 41, 371–394 (2020). https://doi.org/10.1007/s10712-019-09563-7</p><p>[4] Gagliardi V., Benedetto A., Bianchini Ciampoli L., D’Amico F., Alani A., Tosti F., 2020. Health monitoring approach for transport infrastructure and bridges by satellite remote sensing Persistent Scatterer Interferometry (PSI). Proc.SPIE 11534. https://doi.org/10.1117/12.2572395</p><p>[5] Bianchini Ciampoli L., Gagliardi V., Calvi A., D’Amico F., Tosti F., Automatic network-level bridge monitoring by integration of InSAR and GIS catalogues. Proceedings of SPIE - The International Society for Optical Engineering, 11059, (2019). DOI: 10.1117/12.2527299</p>


2021 ◽  
pp. 107759
Author(s):  
Maria Ana Benoliel ◽  
Maria Manso ◽  
Patrícia Dinis Ferreira ◽  
Cristina Matos Silva ◽  
Carlos Oliveira Cruz

2020 ◽  
pp. 002029401988747
Author(s):  
Nadir Subasi ◽  
Ufuk Guner ◽  
Ilker Ustoglu

Safety-critical systems are widely used in many sectors to prevent fatal accidents and prevent loss of life, damage of property, or deterioration of the environment. Implementation of software safety standards as part of the development of safety-critical software is generally considered an essential element of any safety program. Therefore, it has become more critical to produce highly reliable software to meet the safety requirements established by functional safety standards, such as IEC 61508, ISO 26262, and EN 50128. IEC 61508 supports well-known safety mechanisms such as design diversity like N-version (multi-version) programming. N-version (multi-version) programming is a method where multiple functionally equivalent programs are independently developed from the same software specifications. N-version (multi-version) programming is particularly an effective approach to increase the quality of software in a safety-critical system. In this paper, one of the well-known and widely used algorithms in the field of N-version (multi-version) programming, the majority voting algorithm, has been modified with an online stability checker where the decisions of the voter are judged against the stability of the underlying system. The plant where all the theoretical results are implemented is a tilt-rotor system with the proposed N-version (multi-version) programming–based controller. The experimental results show that the modified majority voter-based N-version (multi-version) programming controller provides more reliable control of the plant.


2016 ◽  
Vol 862 ◽  
pp. 307-315
Author(s):  
Darja Gabriska

During a manufacturing process of automotive clutch an explosive substance – xenon is produced. Concentration of this substance must be monitored. Implementation of controls is performed by a safety-critical functions control system.Among main role during the process of risk assessment analysis belong determination of danger and dangerous events associated with the devices. Proactive planning errors and the use of appropriate standards can greatly reduce formation disorders thereby reducing the probability of dangerous consequences. The standard safety subsystems architectures and computation methods for determining the failure intensity is listed in the standards IEC 61508 and IEC 61511. These standards contain information tables with the results of these computations for selected parameter values.We propose a complete failure probability model for the safety functions of the control system. This model is designed to compute the intensity of the critical failure for the standard channel architectures.These architectures were designed with respect to the standard IEC 61508 and were implemented in Matlab.


Author(s):  
Peter Cuninka ◽  
Maximilián Strémy

Abstract The article deals with different procedures for determining the safety integrity level and its applications. The purpose of this research was to evaluate the system and associate it with certain safety integrity level. In this article, we will use IEC 61508, IEC 61511 and IEC 62061 for comparison. The first standard is specified as the superior standard for all safety-critical systems. The second one acts as an extension of the superior standard in the field of functional safety. The last one is aimed at machinery safety.