Distal Radius Fracture: Combination of Volar Plating/Dorsal Bridge Plate

2021 ◽  
pp. 67-77
Author(s):  
Babar Shafiq ◽  
Erik A. Hasenboehler
Hand Surgery ◽  
2006 ◽  
Vol 11 (01n02) ◽  
pp. 67-70 ◽  
Author(s):  
Siu Cheong Koo ◽  
Sheung Tung Ho

Flexor tendon rupture following distal radius fracture is rare. We described a case of flexor pollicis longus rupture, presented five years after volar plating of distal radius fracture.


Hand ◽  
2017 ◽  
Vol 13 (3) ◽  
pp. 336-340 ◽  
Author(s):  
Jerry I. Huang ◽  
Bret Peterson ◽  
Kate Bellevue ◽  
Nicolas Lee ◽  
Sean Smith ◽  
...  

Background: The goal of this study was to compare the biomechanical stability of a 2.4-mm dorsal spanning bridge plate with a volar locking plate (VLP) in a distal radius fracture model, during simulated crutch weight-bearing. Methods: Five paired cadaveric forearms were tested. A 1-cm dorsal wedge osteotomy was created to simulate an unstable distal radius fracture with dorsal comminution. Fractures were fixed with a VLP or a dorsal bridge plate (DBP). Specimens were mounted to a crutch handle, and optical motion-tracking sensors were attached to the proximal and distal segments. Specimens were loaded in compression at 1 mm/s on a servohydraulic test frame until failure, defined as 2 mm of gap site displacement. Results: The VLP construct was significantly more stable to axial load in a crutch weight-bearing model compared with the DBP plate (VLP: 493 N vs DBP: 332 N). Stiffness was higher in the VLP constructs, but this was not statistically significant (VLP: 51.4 N/mm vs DBP: 32.4 N/mm). With the crutch weight-bearing model, DBP failed consistently with wrist flexion and plate bending, whereas VLP failed with axial compression at the fracture site and dorsal collapse. Conclusions: Dorsal spanning bridge plating is effective as an internal spanning fixator in treating highly comminuted intra-articular distal radius fracture and prevents axial collapse at the radiocarpal joint. However, bridge plating may not offer advantages in early weight-bearing or transfer in polytrauma patients, with less axial stability in our crutch weight-bearing model compared with volar plating. A stiffer 3.5-mm DBP or use of a DBP construct without the central holes may be considered for distal radius fractures if the goal is early crutch weight-bearing through the injured extremity.


2015 ◽  
Vol 40 (3) ◽  
pp. 500-504 ◽  
Author(s):  
Sarah Lewis ◽  
Amir Mostofi ◽  
Milan Stevanovic ◽  
Alidad Ghiassi