Performance evaluation of grid-connected power conversion systems integrated with real-time battery monitoring in a battery energy storage system

2019 ◽  
Vol 102 (1) ◽  
pp. 245-258 ◽  
Author(s):  
Yoong Yang Leow ◽  
Chia Ai Ooi ◽  
Muhammad Najwan Hamidi
Energies ◽  
2019 ◽  
Vol 12 (14) ◽  
pp. 2712 ◽  
Author(s):  
Mahmoud Elkazaz ◽  
Mark Sumner ◽  
David Thomas

A new energy management system (EMS) is presented for small scale microgrids (MGs). The proposed EMS focuses on minimizing the daily cost of the energy drawn by the MG from the main electrical grid and increasing the self-consumption of local renewable energy resources (RES). This is achieved by determining the appropriate reference value for the power drawn from the main grid and forcing the MG to accurately follow this value by controlling a battery energy storage system. A mixed integer linear programming algorithm determines this reference value considering a time-of-use tariff and short-term forecasting of generation and consumption. A real-time predictive controller is used to control the battery energy storage system to follow this reference value. The results obtained show the capability of the proposed EMS to lower the daily operating costs for the MG customers. Experimental studies on a laboratory-based MG have been implemented to demonstrate that the proposed EMS can be implemented in a realistic environment.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1482
Author(s):  
Ning Gao ◽  
Xin Lin ◽  
Weimin Wu ◽  
Frede Blaabjerg

Adopting the battery energy storage system is an effective way to compensate the continuously growing fluctuating power generated by renewable sources. The power conversion system is considered as one of the core equipment used for interfacing battery packs to the grid in a battery energy storage system. This paper aims to apply an improved active damping control to a grid-tied power conversion system with LCL filter to attenuate its inherent resonance characteristics. The anti-interference ability is enhanced by estimating the second-order derivation of grid-injected current based on a modified disturbance observer. Meanwhile, the negative effects of parameter mismatch are equivalent to unmeasurable disturbances, which are possible to be compensated by subtracting the estimated values from the modulated voltage references. Moreover, the design method and robustness issue of the disturbance observer are discussed in detail. The presented control algorithm is implemented based on Simulink and dSpace. Detailed simulation results are provided, which can verify the feasibility and correctness of control strategy. Furthermore, an experimental prototype rated at 2.3 kW/110 V is constructed. The experimental results confirm that the presented control method is effective to be applied in the power conversion system (PCS).


Sign in / Sign up

Export Citation Format

Share Document