scholarly journals Impact of stem design and cementation on postoperative femoral antetorsion in 227 patients with total hip arthroplasty (THA)

2020 ◽  
Vol 49 (12) ◽  
pp. 2001-2009
Author(s):  
Tim Fischer ◽  
Christoph Stern ◽  
Benjamin Fritz ◽  
Patrick O. Zingg ◽  
Christian W. A. Pfirrmann ◽  
...  

Abstract Objective In total hip arthroplasty (THA), surgeons attempt to achieve a physiological antetorsion. However, postoperative antetorsion of the femoral stem is known to show large variabilities. The purpose of this study was to assess whether postoperative antetorsion is influenced by stem design or cementation. Materials and methods This retrospective study included 227 patients with a hip prosthesis with five different stem designs (S1: short curved, S2 and S3: standard straight, S4: standard straight collared, S5: cemented straight), who had metal suppressed 1.5T-MRI of the hip between February 2015 and October 2019. Measurement of femoral antetorsion was done independently by two fellowship-trained radiologists on axial images by measuring the angle between the long axis of the femoral neck and the posterior condylar tangent of the knee. Measured angles in the different groups were compared using the t test for independent samples. Results The cementless collared stem S4 showed the highest antetorsion with 18.1° (± 10.5°; range –10°–45°), which was significantly higher than the antetorsion of the collarless S3 with 13.3° (± 8.4°; − 4°–29°) and the cemented S5 with 12.7° (± 7.7°; − 3°–27°) with p = 0.012 and p = 0.007, respectively. S1 and S2 showed an antetorsion of 14.8° (± 10.0°; 1°–37°) and 14.1° (± 12.2°; − 20°–41°). The torsional variability of the cementless stems (S1–4) was significantly higher compared with that of the cemented S5 with a combined standard deviation of 10.5° and 7.7° (p = 0.019). Conclusion Prosthesis design impacts the postoperative femoral antetorsion, with the cementless collared stem showing the highest antetorsion. Cemented stems demonstrated significantly lower variability, suggesting the lowest rate of inadvertent malrotation.

1997 ◽  
Vol 7 (3) ◽  
pp. 125-127
Author(s):  
J. Cordes ◽  
K. Sperling ◽  
M. Kramhøft

In the literature, only one case of displacement of a cemented femoral stem from its cement bed during closed reduction of a dislocation has been reported. In that case, it was suggested that the stem design may in part be the explanation for the displacement. Another case with a cemented Müller straight stem is now presented, emphasizing the use of image intensification if reduction proves difficult.


2021 ◽  
Vol 49 (11) ◽  
pp. 030006052110588
Author(s):  
Xuzhuang Ding ◽  
Bingshi Zhang ◽  
Wenao Li ◽  
Jia Huo ◽  
Sikai Liu ◽  
...  

Objective We performed a retrospective study to compare the accuracy of preoperative planning using three-dimensional AI-HIP software and traditional two-dimensional manual templating to predict the size and position of prostheses. The purpose of this study was to evaluate the accuracy of AI-HIP in preoperative planning for primary total hip arthroplasty. Methods In total, 316 hips treated from April 2019 to June 2020 were retrospectively reviewed. A typical preoperative planning process for patients was implemented to compare the accuracy of the two preoperative planning methods with respect to prosthetic size and position. Intraclass correlation coefficients (ICCs) were used to evaluate the homogeneity between the actual prosthetic size and position and the preoperative planning method. Results When AI-HIP software and manual templating were used for preoperative planning, the stem agreement was 87.7% and 58.9%, respectively, and the cup agreement was 94.0% and 65.2%, respectively. The results showed that when AI-HIP software was used, an extremely high level of consistency (ICC > 0.95) was achieved for the femoral stem size, cup size, and femoral osteotomy level (ICC = 0.972, 0.962, and 0.961, respectively). Conclusion AI-HIP software showed excellent reliability for predicting the component size and implant position in primary total hip arthroplasty.


2016 ◽  
Vol 27 (1) ◽  
pp. 26-34 ◽  
Author(s):  
Ashleen R. Knutsen ◽  
Nicole Lau ◽  
Donald B. Longjohn ◽  
Edward Ebramzadeh ◽  
Sophia N. Sangiorgio

Introduction Periprosthetic bone loss may lead to major complications in total hip arthroplasty (THA), including loosening, migration, and even fracture. This study analysed the influence of femoral implant designs on periprosthetic bone mineral density (BMD) after THA. Methods The results of all previous published studies reporting periprosthetic femoral BMD following THA were compiled. Using these results, we compared percent changes in bone loss as a function of: femoral stem fixation, material, and geometry. Results The greatest bone loss was in the calcar region (Gruen Zone 7). Overall, cemented stems had more bone loss distally than noncemented stems, while noncemented stems had more proximal bone loss than cemented stems. Within noncemented stems, cobalt-chromium (CoCr) stems had nearly double the proximal bone loss compared to titanium (Ti) alloy stems. Finally, within noncemented titanium alloy group, straight stems had less bone loss than anatomical, tapered, and press-fit designs. Discussion The findings from the present study quantified percent changes in periprosthetic BMD as a function of fixation method, alloy, and stem design. While no one stem type was identified as ideal, we now have a clearer understanding of the influence of stem design on load transfer to the surrounding bone.


2019 ◽  
Vol 101-B (4) ◽  
pp. 365-371 ◽  
Author(s):  
D. Nam ◽  
R. Salih ◽  
C. R. Nahhas ◽  
R. L. Barrack ◽  
R. M. Nunley

Aims Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell ( vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed ‘high-risk’ for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study’s purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. Patients and Methods This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m2 and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (sd 6.5)) were enrolled. All patients had a minimum of two years’ clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis. Results Mean Harris Hip Scores improved from 54.1 (sd 20.5) to 91.2 (sd 10.8) at two years postoperatively (p < 0.001). All patients had radiologically well-fixed components, no patients experienced any instability, and no patients required any further intervention. Mean cobalt levels increased from 0.065 ug/l (sd 0.03) preoperatively to 0.30 ug/l (sd 0.51) at one year postoperatively (p = 0.01) but decreased at two years postoperatively to 0.16 ug/l (sd 0.23; p = 0.2). Four patients (9.3%) had a cobalt level outside the reference range (0.03 ug/l to 0.29 ug/l) at two years postoperatively, with values from 0.32 ug/l to 0.94 ug/l. The mean femoral BMD ratio was maintained in Gruen zones 2 to 7 at both one and two years postoperatively using this stem design. At two years postoperatively, mean BMD in the medial calcar was 101.5% of the baseline value. Conclusion Use of a modular DM prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at two years postoperatively demonstrates the necessity of continued surveillance in this cohort. Cite this article: Bone Joint J 2019;101-B:365–371.


2020 ◽  
Vol 13 (1) ◽  
pp. 51-55
Author(s):  
William Messamore ◽  
Matthew Vopat ◽  
Elizabeth Helsper ◽  
Andrew Bachinskas ◽  
Michelle Nentwig ◽  
...  

Introduction. Direct anterior approach (DAA) total hip arthroplasty (THA) has become increasingly popular, largely due to utilization of a true internervous and intermuscular plane. However, recent literature has demonstrated an increased rate of femoral implant subsidence with this approach. Hence, different femoral implants, such as the tri-tapered femoral stem, have been developed to facilitate proper component insertion and positioning to prevent this femoral subsidence. The purpose of this study was to evaluate the subsidence rate of a tri-tapered femoral stem implanted utilizing a DAA, and to determine if the proximal femoral bone quality affects the rate of subsidence. Methods. A retrospective analysis of 155 consecutive primary THAs performed by a single surgeon was conducted. Age, gender, primary diagnosis, and radiographic measurements of each subject were recorded. Radiological evaluations, such as bone quality, femoral canal fill, and implant subsidence, were measured on standardized anteroposterior (AP) and frog-leg lateral radiographs of the hip at 6-week and 6-month postoperative follow-up evaluations. Results. The average subsidence of femoral stems was 1.18 ± 0.8 mm. There was no statistical difference in the amount of subsidence based on diagnosis or proximal femora quality. The tri-tapered stem design consistently filled the proximal canal with an average of 91.9 ± 4.9% fill. Subsidence was not significantly associated with age, canal flare index (CFI), or experience of the surgeon. Conclusion. THA utilizing the DAA with a tri-tapered femoral stem can achieve consistent and reliable fit regardless of proximal femoral bone quality.


2018 ◽  
Vol 33 (3) ◽  
pp. 800-804 ◽  
Author(s):  
Krishna R. Cidambi ◽  
Steven L. Barnett ◽  
Paige R. Mallette ◽  
Jay J. Patel ◽  
Nader A. Nassif ◽  
...  

2008 ◽  
Vol 23 (5) ◽  
pp. 670-676 ◽  
Author(s):  
Stephen J. Incavo ◽  
Bruce D. Beynnon ◽  
Kathryn M. Coughlin

1987 ◽  
Vol 58 (04) ◽  
pp. 1040-1042
Author(s):  
J J M L Hoffmann ◽  
J H J P M Kortmann

SummaryThe behaviour of the contact system was studied in 40 patients with total hip arthroplasty, by measuring plasma prekallikrein, spontaneous kallikrein activity and factor XII. In the literature it had been shown that patients with complications from this operation had decreased prekallikrein and increased kallikrein activity (M. Nakahara. Acta orthop scand 1982; 53: 591-6). In the present study, comprising patients with and without pain and proven loosening of the hip prosthesis, these findings could only partially be confirmed. Patients with a loosened prosthesis had significantly lower prekallikrein (mean 0.78 ± 0.28 U/ml; p <0.01) than patients without problems, but no detectable kallikrein activity in plasma. Patients with pain but no loosening had normal prekallikrein (1.04 ±0 0.26 U/ml) and also no demonstrable kallikrein activity. Factor XII was normal in all patient groups. It is concluded that decreased prekallikrein is limited to patients with a loosened hip prosthesis, with or without pain.


Sign in / Sign up

Export Citation Format

Share Document