Comparison of tube-guided and guideless videolaryngoscope for tracheal intubation during chest compression in a manikin: a randomized crossover trial

2014 ◽  
Vol 29 (3) ◽  
pp. 331-337 ◽  
Author(s):  
Daisuke Okada ◽  
Nobuyasu Komasawa ◽  
Shunsuke Fujiwara ◽  
Toshiaki Minami
CJEM ◽  
2016 ◽  
Vol 18 (6) ◽  
pp. 461-468 ◽  
Author(s):  
Shawn Liu ◽  
Christian Vaillancourt ◽  
Ann Kasaboski ◽  
Monica Taljaard

ABSTRACTObjectivesThis study sought to measure bystander fatigue and cardiopulmonary resuscitation (CPR) quality after five minutes of CPR using the continuous chest compression (CCC) versus the 30:2 chest compression to ventilation method in older lay persons, a population most likely to perform CPR on cardiac arrest victims.MethodsThis randomized crossover trial took place at three tertiary care hospitals and a seniors’ center. Participants were aged ≥55 years without significant physical limitations (frailty score ≤3/7). They completed two 5-minute CPR sessions (using 30:2 and CCC) on manikins; sessions were separated by a rest period. We used concealed block randomization to determine CPR method order. Metronome feedback maintained a compression rate of 100/minute. We measured heart rate (HR), mean arterial pressure (MAP), and Borg Exertion Scale. CPR quality measures included total number of compressions and number of adequate compressions (depth ≥5 cm).ResultsSixty-three participants were enrolled: mean age 70.8 years, female 66.7%, past CPR training 60.3%. Bystander fatigue was similar between CPR methods: mean difference in HR -0.59 (95% CI −3.51-2.33), MAP 1.64 (95% CI −0.23-3.50), and Borg 0.46 (95% CI 0.07-0.84). Compared to 30:2, participants using CCC performed more chest compressions (480.0 v. 376.3, mean difference 107.7; p<0.0001) and more adequate chest compressions (381.5 v. 324.9, mean difference. 62.0; p=0.0001), although good compressions/minute declined significantly faster with the CCC method (p=0.0002).ConclusionsCPR quality decreased significantly faster when performing CCC compared to 30:2. However, performing CCC produced more adequate compressions overall with a similar level of fatigue compared to the 30:2 method.


Author(s):  
Anne Lee Solevag ◽  
Po-Yin Cheung ◽  
Elliott Li ◽  
Sarah Zhenchun Xue ◽  
Megan O'Reilly ◽  
...  

2018 ◽  
Vol 31 (1) ◽  
Author(s):  
Lukasz Szarpak ◽  
Agnieszka Madziala ◽  
Marek Dabrowski ◽  
Halla Kaminska ◽  
Wojciech Wieczorek ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Shunsuke Fujiwara ◽  
Nobuyasu Komasawa ◽  
Sayuri Matsunami ◽  
Daisuke Okada ◽  
Toshiaki Minami

Background. Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation. We compared the utility of the Pentax-AWS Airwayscope (AWS) with the Glidescope (GS) during chest compressions on an infant manikin.Methods. Twenty-four anesthesiologists with more than two years of experience performed tracheal intubation on an infant manikin using the AWS and GS, with or without chest compressions.Results. In GS trials, none of the participants failed without compressions, while three failed with compressions. In AWS trials, all participants succeeded regardless of chest compressions. Intubation time was significantly longer with chest compressions with the GS (P<0.05), but not with the AWS. Difficulty of operation on a visual analog scale (VAS) for laryngoscopy did not increase significantly with chest compressions with either the GS or the AWS, while the VAS for tube passage through the glottis increased with compressions with the GS, but not with the AWS.Conclusion. We conclude that in infant simulations managed by anesthesiologists, the AWS performed better than the GS for endotracheal intubation with chest compressions.


Sign in / Sign up

Export Citation Format

Share Document