spine motion
Recently Published Documents


TOTAL DOCUMENTS

209
(FIVE YEARS 33)

H-INDEX

31
(FIVE YEARS 2)

2022 ◽  
Vol 99 ◽  
pp. 103612
Author(s):  
Victor C.H. Chan ◽  
Timothy N. Welsh ◽  
Luc Tremblay ◽  
David M. Frost ◽  
Tyson A.C. Beach

Author(s):  
Alexander Breen ◽  
Diana De Carvalho ◽  
Martha Funabashi ◽  
Greg Kawchuk ◽  
Isabelle Pagé ◽  
...  

Lumbar instability has long been thought of as the failure of lumbar vertebrae to maintain their normal patterns of displacement. However, it is unknown what these patterns consist of. Research using quantitative fluoroscopy (QF) has shown that continuous lumbar intervertebral patterns of rotational displacement can be reliably measured during standing flexion and return motion using standardised protocols and can be used to assess patients with suspected lumbar spine motion disorders. However, normative values are needed to make individualised comparisons. One hundred and thirty-one healthy asymptomatic participants were recruited and performed guided flexion and return motion by following the rotating arm of an upright motion frame. Fluoroscopic image acquisition at 15fps was performed and individual intervertebral levels from L2-3 to L5-S1 were tracked and analysed during separate outward flexion and return phases. Results were presented as proportional intervertebral motion representing these phases using continuous means and 95%CIs, followed by verification of the differences between levels using Statistical Parametric Mapping (SPM). A secondary analysis of 8 control participants matched to 8 patients with chronic, non-specific low back pain (CNSLBP) was performed for comparison. One hundred and twenty-seven asymptomatic participants’ data were analysed. Their ages ranged from 18 to 70 years (mean 38.6) with mean body mass index 23.8 kg/m2 48.8% were female. Both the flexion and return phases for each level evidenced continuous change in mean proportional motion share, with narrow confidence intervals, highly significant differences and discrete motion paths between levels as confirmed by SPM. Patients in the secondary analysis evidenced significantly less L5-S1 motion than controls (p < 0.05). A reference database of spinal displacement patterns during lumbar (L2-S1) intersegmental flexion and return motion using a standardised motion protocol using fluoroscopy is presented. Spinal displacement patterns in asymptomatic individuals were found to be distinctive and consistent for each intervertebral level, and to continuously change during bending and return. This database may be used to allow continuous intervertebral kinematics to drive dynamic models of joint and muscular forces as well as reference values against which to make patient-specific comparisons in suspected cases of lumbar spine motion disorders.


Author(s):  
FU CAO ◽  
RONGCHANG FU ◽  
WENYUAN WANG

Lesions in facet joints such as bone hyperplasia and degenerative changes in the intervertebral discs, can compress nerve roots and the spinal cord, leading to cervical spondylosis (CS). Lesions in these parts of the spine are commonly related to abnormal loads caused by bad posture of the cervical spine. This study aimed to understand the potential mechanical effects of load amplitude on cervical spine motion to provide a theoretical basis for the biomechanical causes of CS, and to provide a reference for preventing of the condition. In this study, a finite element model of the normal human cervical spine (C1-C7) was established and validated using an infrared motion capture system to analyze the effects of flexion angle on the stresses experienced by intervertebral discs, the anterior edge of the vertebral body, the pedicle, uncinate and facet joints. Our analysis indicated that the intervertebral disc load increased by at least 70% during the 20∘ to 45∘ flexion of the neck with 121% load increase in the vertebrae. In the intervertebral discs, the stress was largest at C4-C5, and the stress was moderate at C5-C6. These results are consistent with clinical CS prone site research. According to Wolff’s law, when bones are placed under large stresses, hyperplasia can result to allow adaptation to large loads. Increased cervical spine flexion angles caused the proliferation of bone in the above-mentioned parts of the spine and can accelerate accelerating the appearance of CS.


Author(s):  
Mohammad Mehdi Alemi ◽  
Katelyn A. Burkhart ◽  
Andrew C. Lynch ◽  
Brett T. Allaire ◽  
Seyed Javad Mousavi ◽  
...  

Motion analysis is increasingly applied to spine musculoskeletal models using kinematic constraints to estimate individual intervertebral joint movements, which cannot be directly measured from the skin surface markers. Traditionally, kinematic constraints have allowed a single spinal degree of freedom (DOF) in each direction, and there has been little examination of how different kinematic constraints affect evaluations of spine motion. Thus, the objective of this study was to evaluate the performance of different kinematic constraints for inverse kinematics analysis. We collected motion analysis marker data in seven healthy participants (4F, 3M, aged 27–67) during flexion–extension, lateral bending, and axial rotation tasks. Inverse kinematics analyses were performed on subject-specific models with 17 thoracolumbar joints allowing 51 rotational DOF (51DOF) and corresponding models including seven sets of kinematic constraints that limited spine motion from 3 to 9DOF. Outcomes included: (1) root mean square (RMS) error of spine markers (measured vs. model); (2) lag-one autocorrelation coefficients to assess smoothness of angular motions; (3) maximum range of motion (ROM) of intervertebral joints in three directions of motion (FE, LB, AR) to assess whether they are physiologically reasonable; and (4) segmental spine angles in static ROM trials. We found that RMS error of spine markers was higher with constraints than without (p < 0.0001) but did not notably improve kinematic constraints above 6DOF. Compared to segmental angles calculated directly from spine markers, models with kinematic constraints had moderate to good intraclass correlation coefficients (ICCs) for flexion–extension and lateral bending, though weak to moderate ICCs for axial rotation. Adding more DOF to kinematic constraints did not improve performance in matching segmental angles. Kinematic constraints with 4–6DOF produced similar levels of smoothness across all tasks and generally improved smoothness compared to 9DOF or unconstrained (51DOF) models. Our results also revealed that the maximum joint ROMs predicted using 4–6DOF constraints were largely within physiologically acceptable ranges throughout the spine and in all directions of motions. We conclude that a kinematic constraint with 5DOF can produce smooth spine motions with physiologically reasonable joint ROMs and relatively low marker error.


Author(s):  
Solène Prost ◽  
Benjamin Blondel ◽  
Vincent Pomero ◽  
Guillaume Authier ◽  
Christophe Boulay ◽  
...  

2021 ◽  
Vol 10 (13) ◽  
pp. 2931
Author(s):  
Yoon Jung Kim ◽  
Chahnmee Hur ◽  
Hyun-Kyu Yoon ◽  
Hyung-Chul Lee ◽  
Hee-Pyoung Park ◽  
...  

We hypothesized that external laryngeal manipulation would reduce cervical spine motion during video laryngoscopic intubation under manual in-line stabilization by reducing the force required to lift the videolaryngoscope. In this randomized crossover trial, 27 neurointerventional patients underwent two consecutive videolaryngoscopic intubation attempts under manual in-line stabilization. External laryngeal manipulation was applied to all patients in either the first or second attempt. In the second attempt, we tried to reproduce the percentage of glottic opening score obtained in the first attempt. Primary outcomes were cervical spine motion during intubation at the occiput-C1, C1–C2, and C2–C5 segments. The intubation success rate (secondary outcome measure) was recorded. Cervical spine motion during intubation at the occiput-C1 segment was significantly smaller with than without external laryngeal manipulation (7.4° ± 4.6° vs. 11.5° ± 4.8°, mean difference −4.1° (98.33% confidence interval −5.8° to −2.3°), p < 0.001), showing a reduction of 35.7%. Cervical spine motion during intubation at the other segments was not significantly different with versus without external laryngeal manipulation. All intubations were achieved successfully regardless of the application of external laryngeal manipulation. External laryngeal manipulation is a useful method to reduce upper cervical spine motion during videolaryngoscopic intubation under manual in-line stabilization.


Author(s):  
Alizée Koszulinski ◽  
Eliot Stantinat ◽  
Léa Ollivier ◽  
Juan Sandoval ◽  
Med Amine Laribi

2021 ◽  
Vol 1 ◽  
pp. 100007
Author(s):  
Sara Lener ◽  
Werner Schmölz ◽  
Anto Abramovic ◽  
Patrick Kluger ◽  
Claudius Thomé ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document