M. S. Ballal ◽  
H. M. Suryawanshi ◽  
T. Venkateswara Reddy

The basic power quality problems in the distribution network are voltage sag (dip), voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS) technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.


2013 ◽  
Vol 31 (4) ◽  
pp. 671-683 ◽  
Author(s):  
A. Krishnamoorthy ◽  
P. K. Pramod ◽  
S. R. Chakravarthy

1971 ◽  
Vol 8 (4) ◽  
pp. 835-837 ◽  
Author(s):  
İzzet Şahin

In [4], the limiting behaviour of a stochastic system with two types of input was investigated by reducing the problem to the solution of an integral equation. In this note we use the same approach to study the equilibrium waiting time problem for the general single server queue with preemptive service interruptions. (For a comprehensive account of the existing literature on queues with service interruptions we refer to [2] and [3].)