Superpixel-based Structural Similarity Metric for Image Fusion Quality Evaluation

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Eryan Wang ◽  
Bin Yang ◽  
Lihui Pang
2011 ◽  
Vol 255-260 ◽  
pp. 2072-2076
Author(s):  
Yi Yong Han ◽  
Jun Ju Zhang ◽  
Ben Kang Chang ◽  
Yi Hui Yuan ◽  
Hui Xu

Under the assumption that human visual perception is highly adapted for extracting structural information from a scene, we present a new approach using structural similarity index for assessing quality in image fusion. The advantages of our measures are that they do not require a reference image and can be easily computed. Numerous simulations demonstrate that our measures are conform to subjective evaluations and can be able to assess different image fusion methods.


2021 ◽  
pp. 1-13
Author(s):  
Yanjie Qi ◽  
Zehui Yang ◽  
Lin Kang

Due to the limitation of dynamic range of the imaging device, the fixed-voltage X-ray images often produce overexposed or underexposed regions. Some structure information of the composite steel component is lost. This problem can be solved by fusing the multi-exposure X-ray images taken by using different voltages in order to produce images with more detailed structures or information. Due to the lack of research on multi-exposure X-ray image fusion technology, there is no evaluation method specially for multi-exposure X-ray image fusion. For the multi-exposure X-ray fusion images obtained by different fusion algorithms may have problems such as the detail loss and structure disorder. To address these problems, this study proposes a new multi-exposure X-ray image fusion quality evaluation method based on contrast sensitivity function (CSF) and gradient amplitude similarity. First, with the idea of information fusion, multiple reference images are fused into a new reference image. Next, the gradient amplitude similarity between the new reference image and the test image is calculated. Then, the whole evaluation value can be obtained by weighting CSF. In the experiments of MEF Database, the SROCC of the proposed algorithm is about 0.8914, and the PLCC is about 0.9287, which shows that the proposed algorithm is more consistent with subjective perception in MEF Database. Thus, this study demonstrates a new objective evaluation method, which generates the results that are consistent with the subjective feelings of human eyes.


2018 ◽  
Vol 11 (4) ◽  
pp. 1937-1946
Author(s):  
Nancy Mehta ◽  
Sumit Budhiraja

Multimodal medical image fusion aims at minimizing the redundancy and collecting the relevant information using the input images acquired from different medical sensors. The main goal is to produce a single fused image having more information and has higher efficiency for medical applications. In this paper modified fusion method has been proposed in which NSCT decomposition is used to decompose the wavelet coefficients obtained after wavelet decomposition. NSCT being multidirectional,shift invariant transform provide better results.Guided filter has been used for the fusion of high frequency coefficients on account of its edge preserving property. Phase congruency is used for the fusion of low frequency coefficients due to its insensitivity to illumination contrast hence making it suitable for medical images. The simulated results show that the proposed technique shows better performance in terms of entropy, structural similarity index, Piella metric. The fusion response of the proposed technique is also compared with other fusion approaches; proving the effectiveness of the obtained fusion results.


2017 ◽  
pp. 711-723
Author(s):  
Vikrant Bhateja ◽  
Abhinav Krishn ◽  
Himanshi Patel ◽  
Akanksha Sahu

Medical image fusion facilitates the retrieval of complementary information from medical images and has been employed diversely for computer-aided diagnosis of life threatening diseases. Fusion has been performed using various approaches such as Pyramidal, Multi-resolution, multi-scale etc. Each and every approach of fusion depicts only a particular feature (i.e. the information content or the structural properties of an image). Therefore, this paper presents a comparative analysis and evaluation of multi-modal medical image fusion methodologies employing wavelet as a multi-resolution approach and ridgelet as a multi-scale approach. The current work tends to highlight upon the utility of these approaches according to the requirement of features in the fused image. Principal Component Analysis (PCA) based fusion algorithm has been employed in both ridgelet and wavelet domains for purpose of minimisation of redundancies. Simulations have been performed for different sets of MR and CT-scan images taken from ‘The Whole Brain Atlas'. The performance evaluation has been carried out using different parameters of image quality evaluation like: Entropy (E), Fusion Factor (FF), Structural Similarity Index (SSIM) and Edge Strength (QFAB). The outcome of this analysis highlights the trade-off between the retrieval of information content and the morphological details in finally fused image in wavelet and ridgelet domains.


Sign in / Sign up

Export Citation Format

Share Document