Influence of temperature on chiral high-performance liquid chromatographic separations of oxazepam and Prominal on chemically bonded β-cyclodextrin as stationary phase

1994 ◽  
Vol 666 (1-2) ◽  
pp. 433-438 ◽  
Author(s):  
Karin Cabrera ◽  
Dieter Lubda
2021 ◽  
Vol 14 (2) ◽  
pp. 98
Author(s):  
Ratih Ratih ◽  
Hermann Wätzig ◽  
Azminah Azminah ◽  
Mufarreh Asmari ◽  
Benjamin Peters ◽  
...  

Chondroitin sulfate A was covalently immobilized onto a monolithic silica epoxy column involving a Schiff base formation in the presence of ethylenediamine as a spacer and evaluated in terms of its selectivity in enantioseparation. The obtained column was utilized as a chiral stationary phase in enantioseparation of amlodipine and verapamil using a mobile phase consisting of 50 mM phosphate buffer pH 3.5 and UV detection. Sample dilution by organic solvents (preferably 25% v/v acetonitrile-aqueous solution) was applied to achieve baseline enantioresolution (Rs > 3.0) of the individual drug models within 7 min, an excellent linearity (R2 = 0.999) and an interday repeatability of 1.1% to 1.8% RSD. The performance of the immobilized column for quantification of racemate in commercial tablets showed a recovery of 86–98% from tablet matrices. Computational modeling by molecular docking was employed to investigate the feasible complexes between enantiomers and the chiral selector.


Sign in / Sign up

Export Citation Format

Share Document