Mechanical impedance of the human hand-arm system subject to sinusoidal and stochastic excitations

1995 ◽  
Vol 16 (2) ◽  
pp. 135-145 ◽  
Author(s):  
R. Gurram ◽  
S. Rakheja ◽  
G.J. Gouw
2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Wenjie Zhang ◽  
Qichao Wang ◽  
Zheng Xu ◽  
Hongmei Xu ◽  
Hang Li ◽  
...  

In order to investigate the effects of hand-arm posture, grip force, push force, and vibration excitation intensity on the mechanical impedance of human hand-arm system, a test system with a self-developed vibration handle has been prepared. Based on the testing system, the mechanical impedance of the hand-arm system of seven Chinese adult males were tested and calculated under the random vibration excitation with the frequency of 10–1000 Hz. The results reveal that when the frequency is lower (<40 Hz), the hand-arm system with an elbow angle of 180o produces a higher mechanical impedance; when the frequency ranges from 40 Hz to 100 Hz, the hand-arm system with an elbow angle of 90o generates a higher mechanical impedance; while when the frequency is higher (>100 Hz), the hand-arm posture seems to have no obvious effect on the mechanical impedance. Higher grip or push force would increase the frequency corresponding to the peak value of the mechanical impedance and often correspond to a higher mechanical impedance in a specific frequency range (30–200 Hz). When the frequency is lower (<140 Hz), vibration intensity has certain effects on the mechanical impedance of the hand-arm system. In conclusion, vibration intensity does not directly affect the mechanical impedance, but an increase in grip or push force often causes an increase in mechanical impedance and a higher frequency that corresponds to the peak of mechanical impedance.


2005 ◽  
Vol 38 (5) ◽  
pp. 1165-1175 ◽  
Author(s):  
R.G. Dong ◽  
J.Z. Wu ◽  
T.W. McDowell ◽  
D.E. Welcome ◽  
A.W. Schopper

1976 ◽  
Vol 20 (14) ◽  
pp. 267-271
Author(s):  
C.W. Suggs ◽  
John Wayne Mishoe

Investigation of hand-arm vibration by means of mechanical impedance techniques has provided objective evaluation of the observation that most of the higher frequency vibration inputs at the hand are not transmitted into the arm. This is reflected in the impedance curves which show two orders of magnitude decrease in apparent mass as frequency is increased from 50 Hz to 1000 Hz. The system may be modeled as damped spring-mass system containing three masses interconnected by springs and dampers.


2004 ◽  
Vol 16 (6) ◽  
pp. 635-642 ◽  
Author(s):  
Yusaku Takeda ◽  
◽  
Yoshiyuki Tanaka ◽  
Toshio Tsuji

Dynamic characteristics of a human extremity are usually expressed using the mechanical impedance. This paper examines hand impedance in dual arm movements while posture was maintained in dual-arm configurations. The results of experiments show that the orientation of viscosity ellipses roughly agrees with the human sagittal axis, tending to be oriented similar to stiffness ellipses. Viscosity and stiffness amplitude and orientation exceed those of single arm. Our results will be used in human-robot cooperation systems and in analyzing human movements.


1989 ◽  
Vol 3 (3) ◽  
pp. 235-242 ◽  
Author(s):  
Ronnie Lundström ◽  
Lage Burström