scholarly journals Adverse Reaction to Zirconia in a Modern Total Hip Arthroplasty with Ceramic Head

2020 ◽  
Vol 6 (3) ◽  
pp. 612-616.e1
Author(s):  
Kwesi G. Dawson-Amoah ◽  
Bradford S. Waddell ◽  
Rohan Prakash ◽  
Michael M. Alexiades
2014 ◽  
Vol 29 (12) ◽  
pp. 2412-2414 ◽  
Author(s):  
Bun-Jung Kang ◽  
Yong-Chan Ha ◽  
Sun-Chul Hwang ◽  
Young-Kyun Lee ◽  
Kyung-Hoi Koo

2008 ◽  
Vol 90 (2) ◽  
pp. 329-336 ◽  
Author(s):  
Kyung-Hoi Koo ◽  
Yong-Chan Ha ◽  
Woon Hwa Jung ◽  
Sang-Rim Kim ◽  
Jeong Joon Yoo ◽  
...  

1991 ◽  
Vol 6 (4) ◽  
pp. 371-374 ◽  
Author(s):  
Angel Peiró ◽  
José Pardo ◽  
Román Navarrete ◽  
Luis Rodriguez-Alonso ◽  
Francisco Martos

2009 ◽  
Vol 468 (8) ◽  
pp. 2135-2142 ◽  
Author(s):  
Panagiotis Aroukatos ◽  
Maria Repanti ◽  
Thomas Repantis ◽  
Vassiliki Bravou ◽  
Panagiotis Korovessis

2013 ◽  
Vol 54 (6) ◽  
pp. 1550 ◽  
Author(s):  
Jae-Hwi Nho ◽  
Jong-Seok Park ◽  
Ui-Seoub Song ◽  
Woo-Jong Kim ◽  
You-Sung Suh

2001 ◽  
Vol 391 ◽  
pp. 198-209 ◽  
Author(s):  
Keiji Haraguchi ◽  
Nobuhiko Sugano ◽  
Takashi Nishii ◽  
Takashi Sakai ◽  
Hideki Yoshikawa ◽  
...  

2021 ◽  
Author(s):  
Bum-Jin Shim ◽  
Chang Hyun Choi ◽  
Inha Woo ◽  
Chan Ho Park

Abstract Background: Recently, the use of ceramic-on-polyethylene (CoP) bearing surfaces has increased in the United States with the development of material properties. However, it remains controversial which bearing couples are effective. The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional polyethylene liner. Methods: We retrospectively reviewed 160 hips (147 patients with a mean age of 56 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003. The wear rate was evaluated using the PolyWare program Version 8 (Draftware Developers Inc., IN, USA) in 32 hips followed-up for at least 15 years. In addition, we evaluated the Kaplan-Meier survivorship.Results: Linear wear and volumetric wear rates were 0.102±0.57 mm/year and 30.2±27.5 mm3/year, respectively. Fourteen reoperations due to all causes and 10 revisions were performed during the follow-up period. The 15-year survival rate was 84.1% for any surgery as the endpoint and 87.6% for the revision surgery as the endpoint. Most of the causes of revision were cup loosening, and no ceramic head fracture occurred.Conclusions: The CoP bearing surface maintains the advantages of the soft polyethylene surface and has good resistance to wear. Therefore, alumina ceramic on newer polyethylene could certainly be a good alternative bearing couple without any concern for ceramic fractures, especially in younger patients.Level of evidence: Level III, retrospective cohort design


Sign in / Sign up

Export Citation Format

Share Document