Patients Following Revision Total Hip Arthroplasty With Modular Dual Mobility Components and Cobalt-Chromium Inner Metal Head are at Risk of Increased Serum Metal Ion Levels

2020 ◽  
Vol 35 (6) ◽  
pp. S294-S298 ◽  
Author(s):  
Roberto Civinini ◽  
Andrea Cozzi Lepri ◽  
Christian Carulli ◽  
Fabrizio Matassi ◽  
Marco Villano ◽  
...  
2019 ◽  
Vol 101-B (4) ◽  
pp. 365-371 ◽  
Author(s):  
D. Nam ◽  
R. Salih ◽  
C. R. Nahhas ◽  
R. L. Barrack ◽  
R. M. Nunley

Aims Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell ( vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed ‘high-risk’ for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study’s purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. Patients and Methods This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m2 and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (sd 6.5)) were enrolled. All patients had a minimum of two years’ clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis. Results Mean Harris Hip Scores improved from 54.1 (sd 20.5) to 91.2 (sd 10.8) at two years postoperatively (p < 0.001). All patients had radiologically well-fixed components, no patients experienced any instability, and no patients required any further intervention. Mean cobalt levels increased from 0.065 ug/l (sd 0.03) preoperatively to 0.30 ug/l (sd 0.51) at one year postoperatively (p = 0.01) but decreased at two years postoperatively to 0.16 ug/l (sd 0.23; p = 0.2). Four patients (9.3%) had a cobalt level outside the reference range (0.03 ug/l to 0.29 ug/l) at two years postoperatively, with values from 0.32 ug/l to 0.94 ug/l. The mean femoral BMD ratio was maintained in Gruen zones 2 to 7 at both one and two years postoperatively using this stem design. At two years postoperatively, mean BMD in the medial calcar was 101.5% of the baseline value. Conclusion Use of a modular DM prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at two years postoperatively demonstrates the necessity of continued surveillance in this cohort. Cite this article: Bone Joint J 2019;101-B:365–371.


2018 ◽  
Vol 43 (10) ◽  
pp. 2245-2251 ◽  
Author(s):  
Chahine Assi ◽  
Jacques Caton ◽  
Wissam Fawaz ◽  
Camille Samaha ◽  
Kaissar Yammine

2019 ◽  
pp. 112070001987361 ◽  
Author(s):  
Jesús Moreta ◽  
Iker Uriarte ◽  
Xabier Foruria ◽  
Ioar Urra ◽  
Urko Aguirre ◽  
...  

Background: Cementation of polyethylene liners into well-fixed cementless metal shells has become an option during revision total hip arthroplasty (THA). We report the results of cementing a dual-mobility (DM) component into a stable acetabular shell in high-risk patients undergoing revision THA. Methods: A single-centre series of 10 patients undergoing revision THA with a DM cup cemented into an existing well-fixed shell between 2012 and 2016 were retrospectively reviewed. Failure due to aseptic loosening or instability and implant survival at last follow-up were analysed. The average age was 79.2 years and mean follow-up was 3.5 years. Indications were recurrent hip dislocation in 8 cases and intraoperative instability with moderate abductor insufficiency in 2 cases. In cases with recurrent dislocation, the aetiology of instability was classified by Wera type. Results: At the latest follow-up, Harris Hip Scores had improved from 49.3 preoperatively to 71.3 postoperatively ( p = 0.098). In the 8 patients with recurrent dislocation, 4 cases (50%) had an unclear aetiology (Wera type 6), 2 (25%) abductor deficiency (Wera type 3) and 2 (25%) late polyethylene wear (type 5). Postoperative recurrent dislocation occurred in 1 hip (10%). No cases of intraprosthetic dislocation, aseptic loosening of the previous shell or dissociation at the cement-cup interface were identified. Conclusion: Although the follow-up of this series is short, cementation of a DM cup into a previous well-fixed socket seems to be a viable option to treat and prevent instability after revision THA, without providing constraint at the cement-cup interface.


2017 ◽  
Vol 32 (5) ◽  
pp. 1581-1585 ◽  
Author(s):  
Denis Nam ◽  
Rondek Salih ◽  
Katherine M. Brown ◽  
Ryan M. Nunley ◽  
Robert L. Barrack

2018 ◽  
Vol 02 (02) ◽  
pp. 088-091 ◽  
Author(s):  
Perry Evangelista ◽  
Kamil Okroj ◽  
Darren Plummer ◽  
Craig Della Valle ◽  
Ran Schwarzkopf

AbstractDislocation is among the most commonly reported complications following revision total hip arthroplasty. Dual-mobility bearings may lower the risk of dislocation. The authors report the results of a multicenter study evaluating the use of a dual-mobility acetabular cup design that was cemented into a metal shell as part of complex acetabular reconstructions or in cases where the risk of dislocation was felt to be high, such as isolated bearing exchanges. Eighteen patients were identified for being at high risk of dislocation who underwent cementation of a dual-mobility shell that is specifically made for cementation, into a fully porous metal revision acetabular cup (10 patients) or into a well-fixed cup at the time of revision without removal of the existing acetabular component (eight patients). Patients were assessed clinically and radiographically at a minimum of 2 years for the evidence of dislocation, revision surgery, and implant loosening. At a mean of 36 months (range, 25–56 months), one patient died and one was lost to follow-up. There were no known cases of hip dislocation. There was one repeat revision, for a deep infection treated with irrigation and debridement. The mean preoperative Harris Hip Score of 46 (range, 40–79) improved to a mean of 65 points (range, 41–97) at the most recent evaluation. Acetabular components were retained in 8 out of 18 cases and the dual-mobility shell was cemented into it. Cementation of a dual-mobility cup into a shell at the time of a revision surgery is a safe and reliable construct at minimum of 2 years for patients at high risk of dislocation. There were no complications related to the cementation of the cup into the metal shell. Longer follow-up is required to further assess the durability of this construct.


2019 ◽  
Vol 34 (7) ◽  
pp. S287-S291 ◽  
Author(s):  
Ronald C. Huang ◽  
Art L. Malkani ◽  
Steven F. Harwin ◽  
William J. Hozack ◽  
Michael A. Mont ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document