Endovascular Repair of Acute Type B Aortic Dissection: Long-Term Follow-Up of True and False Lumen Diameter Changes

2007 ◽  
Vol 83 (3) ◽  
pp. 1059-1066 ◽  
Author(s):  
Maria Schoder ◽  
Martin Czerny ◽  
Manfred Cejna ◽  
Thomas Rand ◽  
Alfred Stadler ◽  
...  
2011 ◽  
Vol 142 (2) ◽  
pp. e25-e31 ◽  
Author(s):  
Shunsuke Miyahara ◽  
Nobuhiko Mukohara ◽  
Masaomi Fukuzumi ◽  
Naoto Morimoto ◽  
Hirohisa Murakami ◽  
...  

1996 ◽  
Vol 61 (5) ◽  
pp. 1339-1341 ◽  
Author(s):  
John S. Schor ◽  
M. Enver Yerlioglu ◽  
Jan D. Galla ◽  
Steven L. Lansman ◽  
M. Arisan Ergin ◽  
...  

2020 ◽  
Vol 69 ◽  
pp. 451.e5-451.e10
Author(s):  
Mary Lin ◽  
Alison O. Flentje ◽  
Charles Drucker ◽  
Siamak Dahi ◽  
Aakash Shah ◽  
...  

2020 ◽  
Vol 54 (8) ◽  
pp. 756-759
Author(s):  
Amer Harky ◽  
Robert K. Fisher ◽  
Mark L. Field

Purpose: To report a case who required a thoracic endovascular stenting (TEVAR) following the deployment of frozen elephant trunk due to false lumen expansion Case Report: A 47 years old male patient undergone emergency repair of acute type A aortic dissection in 2011 with bioprosthetic aortic root conduit. Seven years later he presented with moderate aortic valve disease and expanding chronic dissection of the aortic arch, therefore a redo operation with replacement of the prosthetic aortic valve, ascending aorta, total arch and deployment of frozen elephant trunk and he was discharged in good health. Several days post discharge he presented with new onset of chest pain and a new dissection involved the thoracoabdominal aorta was noted pressing on the true lumen and the frozen elephant trunk. Following a multi-disciplinary team meeting, TEVAR was deemed as a most appropriate approach and this was achieved successfully, and patient was discharged. At 1 year of follow up, he remains well and asymptomatic. Conclusion: Close imaging follow-up following deployment of a FET is mandatory. A new acute Type B aortic dissection distal to the FET, that causes false lumen propagation parallel to the stented portion, is a surgical emergency and further intervention mandated.


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Hongtao Tie ◽  
Lingwen Kong ◽  
Zhengjie Tu ◽  
Dan Chen ◽  
Delai Zheng ◽  
...  

Abstract Background Open stented elephant trunk (SET) or SET with left subclavian artery (LSCA) to left common carotid artery (LCCA) bypass is proven to a potentially alternative treatment for complicated Stanford type B aortic dissection (TBAD). In the current study, we reported our experience with ten consecutive TBAD patients who underwent open SET. Methods Patients with complicated TBAD underwent open SET from May 2016 to November 2018 in our institution were included. Patients’ clinical data were obtained from the electronic medical record system, and long-term clinical outcomes were collected by telephone interviews or outpatient interviews. Results A total of ten patients with nine males and one female were included, and the average age was 47.3 (31–65) years. Increased D-dimer and fibrinogen degradation products were observed in all patients at admission, and two patients had renal insufficiency. The average postoperative mechanical ventilation time, length of stay in intensive care unit, and postoperative hospital length of stay were 46.9 (6.7–151.2) hours, 7.7 (4–17) days, and 15.7 (10–26) days. No postoperative death occurred. Acute kidney injury and other complications were observed, and they were recovered well when discharge. In long-term follow-up, computed tomography angiography indicated that aortas were completely well remodeled, and blood supply of the brachiocephalic trunks was normal without anastomotic complications. All patients lived well. Conclusion SET or SET with subclavian artery correction shows satisfactory clinical outcomes, and it could be considered as an alternative treatment. Well-designed, large-scale studies with long-term follow-up are still needed.


Sign in / Sign up

Export Citation Format

Share Document