The essential value of the alternatives of the suboptimal choice procedure is different for pigeons and rats

2020 ◽  
Vol 181 ◽  
pp. 104245
Author(s):  
Gabriela E. López-Tolsa ◽  
José Manuel Niño ◽  
Vladimir Orduña
2018 ◽  
Vol 157 ◽  
pp. 574-582 ◽  
Author(s):  
Rodrigo Alba ◽  
William Rodríguez ◽  
Montserrat Martínez ◽  
Vladimir Orduña

2018 ◽  
Vol 111 (1) ◽  
pp. 1-11
Author(s):  
Jeffrey M. Pisklak ◽  
Margaret A. McDevitt ◽  
Roger M. Dunn ◽  
Marcia L. Spetch

1988 ◽  
Vol 31 (2) ◽  
pp. 156-165 ◽  
Author(s):  
P. A. Busby ◽  
Y. C. Tong ◽  
G. M. Clark

The identification of consonants in a/-C-/a/nonsense syllables, using a fourteen-alternative forced-choice procedure, was examined in 4 profoundly hearing-impaired children under five conditions: audition alone using hearing aids in free-field (A),vision alone (V), auditory-visual using hearing aids in free-field (AV1), auditory-visual with linear amplification (AV2), and auditory-visual with syllabic compression (AV3). In the AV2 and AV3 conditions, acoustic signals were binaurally presented by magnetic or acoustic coupling to the subjects' hearing aids. The syllabic compressor had a compression ratio of 10:1, and attack and release times were 1.2 ms and 60 ms. The confusion matrices were subjected to two analysis methods: hierarchical clustering and information transmission analysis using articulatory features. The same general conclusions were drawn on the basis of results obtained from either analysis method. The results indicated better performance in the V condition than in the A condition. In the three AV conditions, the subjects predominately combined the acoustic parameter of voicing with the visual signal. No consistent differences were recorded across the three AV conditions. Syllabic compression did not, therefore, appear to have a significant influence on AV perception for these children. A high degree of subject variability was recorded for the A and three AV conditions, but not for the V condition.


1958 ◽  
Vol 02 (01/02) ◽  
pp. 111-124 ◽  
Author(s):  
E Deutsch ◽  
K Martiny

Summary1. Normal platelets are necessary for induction of normal clot retraction.2. Serotonin does not induce retraction in human platelet-free plasma-clots or enhance clot firmness as measured in the coagulogram.3. Serotonin does not improve clot retraction or firmness in plasma clots with sub-optimal platelet counts.4. Methylserotonin inhibits clot retraction of platelet-rich plasma to a certain extent in moderate doses, whereas, high doses are ineffective. BOL 148 has a similar, but less significant action. There is a possibility that these effects are specific antiserotonin-effects.5. LSD 25 was ineffective in all concentrations used.6. Largactil and reserpin inhibit retraction in high doses. There seems to be a non specific effect caused by the high dose.7. Reserpine does not release a retraction-inducing agent from the platelets, which could be detected in the centrifuged platelet-free plasma used for the incubation.8. Serotonin does not replace the retraction-cofactor of Hartert, or the dialyzable factor of Lüscher in synthetic clotting substrates.9. Serotonin is of no essential value in inducing normal retraction of human plasma clots.


2021 ◽  
Vol 25 ◽  
pp. 233121652110101
Author(s):  
Dmitry I. Nechaev ◽  
Olga N. Milekhina ◽  
Marina S. Tomozova ◽  
Alexander Y. Supin

The goal of the study was to investigate the role of combination products in the higher ripple-density resolution estimates obtained by discrimination between a spectrally rippled and a nonrippled noise signal than that obtained by discrimination between two rippled signals. To attain this goal, a noise band was used to mask the frequency band of expected low-frequency combination products. A three-alternative forced-choice procedure with adaptive ripple-density variation was used. The mean background (unmasked) ripple-density resolution was 9.8 ripples/oct for rippled reference signals and 21.8 ripples/oct for nonrippled reference signals. Low-frequency maskers reduced the ripple-density resolution. For masker levels from −10 to 10 dB re. signal, the ripple-density resolution for nonrippled reference signals was approximately twice as high as that for rippled reference signals. At a masker level as high as 20 dB re. signal, the ripple-density resolution decreased in both discrimination tasks. This result leads to the conclusion that low-frequency combination products are not responsible for the task-dependent difference in ripple-density resolution estimates.


Sign in / Sign up

Export Citation Format

Share Document