Suprapectoral biceps tenodesis: A biomechanical comparison of a new “soft anchor” tenodesis technique versus interference screw biceps tendon fixation

2015 ◽  
Vol 30 (2) ◽  
pp. 188-194 ◽  
Author(s):  
Massimiliano Baleani ◽  
Dunia Francesconi ◽  
Lorenzo Zani ◽  
Sandro Giannini ◽  
Stephen J. Snyder
2005 ◽  
Vol 41 (2) ◽  
pp. 121-127 ◽  
Author(s):  
James L. Cook ◽  
Keith Kenter ◽  
Derek B. Fox

Biceps tenodesis was performed using an arthroscopic-assisted technique on six dogs diagnosed with chronic bicipital tendon pathology. The technique was performed using two different fixation methods (i.e., cannulated interference screw, cannulated screw and tissue washer). All six dogs had successful outcomes in terms of return to full function at a mean follow-up time of 11.7 months after surgery. Arthroscopic biceps tenodesis is a feasible option for surgical management of biceps tendon pathology, and it may have advantages over open tenodesis and open or arthroscopic tenotomy. Further study is needed before definitive recommendations regarding indications, complications, and prognosis associated with arthroscopic biceps tenodesis can be made.


2019 ◽  
Vol 7 (3_suppl2) ◽  
pp. 2325967119S0019
Author(s):  
Richard N. Puzzitiello ◽  
Avinesh Agarwalla ◽  
Joseph N. Liu ◽  
Gregory L. Cvetanovich ◽  
Anirudh K. Gowd ◽  
...  

Objectives: Biceps tenodesis is performed with increasing frequency for various pathologies of the long head biceps tendon (LHBT). Multiple surgical techniques and devices for tenodesis have been described with favorable outcomes. The subpectoral approach provides adequate clinical outcomes; furthermore, recent research suggests that similar outcomes can be achieved via arthroscopic suprapectoral biceps tenodesis. Previous studies have compared the biomechanical profile of suprapectoral and subpectoral biceps tenodesis. There is a paucity of data regarding the biomechanical behavior and construct stability of suprapectoral and subpectoral biceps tenodesis in vivo. The purpose of this investigation is to quantify and compare the behavior of the biceps tenodesis construct in arthroscopic suprapectoral (ASPBT) and open subpectoral (OSPBT) techniques, with radiostereometric analysis (RSA). Methods: This is a prospective cohort study comparing migration of the biceps tendon after suprapectoral and subpectoral biceps tenodesis with Polyetheretherketone (PEEK) interference screw fixation. Thirty consecutive patients were allocated to the subpectoral group, follow by thirty consecutive patients to the suprapectoral group. Patients aged 18-65 years with symptomatic biceps tendinopathy, anterior intertubercular groove tenderness, and positive biceps tension tests were included in the investigation. Patients undergoing revision biceps tenodesis, shoulder arthroplasty, or ruptured LHBT were excluded. A mini skin staple, functioning as a radiostereometric marker, was placed longitudinally within the tendon prior to final fixation with interference screw. Staple stability was confirmed with a hemostat to gravity. The distance from the most proximal portion of the mini skin staple and the most proximal aspect of the humeral head was measured. Following final fixation with an interference screw, AP radiographs were obtained intraoperatively. Follow-up radiographs were one week and 12 weeks post-operatively. A paired and non-paired students t-test were utilized to assess for intra-group and inter-group changes, respectively. Results: A total of 60 consecutive patients (30 per group) were enrolled and available for follow-up imaging at 1 and 12 weeks postoperatively. The average age was 43.5±10.5 years, average BMI was 28.3±5.4, and 50% of the patients were females. Groups were similar with respect to patient demographics and concomitant procedures (P>.05). In the OSPBT group, the average distance of the radiostereometic marker to the proximal humeral head increased on by 26.0 mm (SD, 15.7) from the immediate post-operative radiograph to 3 months postoperatively (P=0.002). In the ASPBT group, the average distance also significantly increased by 24.7 mm (SD, 14.9) from the immediate post-operative radiograph to 3-months postoperatively (P=0.001). The change in distal migration between the ASPBT and OSPBT was not found to be statistically significant (P> 0.05). Conclusion: Biceps tenodesis performed with a PEEK tenodesis screw results in significant distal migration of the biceps tendon by 3 months post-operatively; however, there was no significant difference in distal migration between the OSPBT and ASPBT groups.


2011 ◽  
Vol 27 (2) ◽  
pp. 161-166 ◽  
Author(s):  
Maj Mark A. Slabaugh ◽  
Rachel M. Frank ◽  
Geoffrey S. Van Thiel ◽  
Rebecca M. Bell ◽  
Vincent M. Wang ◽  
...  

2018 ◽  
Vol 12 (1) ◽  
pp. 12-17 ◽  
Author(s):  
Paul J Cagle ◽  
Daniel A London ◽  
Matthew J Gluck ◽  
Sabrina Morel ◽  
Bradford O Parsons

Purpose Pathology involving the long head of the biceps tendon is a common source of shoulder pain. Biceps tenodesis has been successfully used in areas below the pectoralis, above the pectoralis, and above the biceps groove. However, clinical data are lacking for additional techniques for tenodesis at the superior aspect of the biceps groove. Methods A biomechanical comparison was completed examining six matched pairs of cadaveric shoulders. The ultimate load to failure was compared between an inlay and onlay biceps tenodesis at the superior aspect of the biceps groove. Results The results demonstrate an average construct strength of 215 N for the inlay technique and 210 N for the onlay technique. The difference between the two techniques was not significant. Conclusions This study demonstrates similar biomechanical strength for both constructs.