The proximal serrated polyp detection rate is an easy-to-measure proxy for the detection rate of clinically relevant serrated polyps

2015 ◽  
Vol 82 (5) ◽  
pp. 870-877 ◽  
Author(s):  
Joep E.G. IJspeert ◽  
Sascha C. van Doorn ◽  
Ymkje M. van der Brug ◽  
Barbara A.J. Bastiaansen ◽  
Paul Fockens ◽  
...  
Endoscopy ◽  
2020 ◽  
Vol 52 (09) ◽  
pp. 763-772 ◽  
Author(s):  
Maxime E. S. Bronzwaer ◽  
Jasper L. A. Vleugels ◽  
Sascha C. van Doorn ◽  
Marcel G. W. Dijkgraaf ◽  
Paul Fockens ◽  
...  

Abstract Introduction Endoscopists with a high adenoma detection rate (ADR) and proximal serrated polyp detection rate (PSPDR) detect these polyps more frequently, which may be attributable to better recognition of their endoscopic features. Little is known about the association between endoscopic lesion detection and differentiation skills. Therefore, we evaluated the correlation between the ADR, PSPDR, and the sensitivity of optical diagnosis for adenomas and serrated polyps. Methods We performed an exploratory post-hoc analysis of the DISCOUNT-2 study, including complete colonoscopies after a positive fecal immunochemical test (FIT) performed by endoscopists who performed ≥ 50 colonoscopies. The correlations between the ADR, PSPDR, and the sensitivity of optical diagnosis were calculated using Pearson’s rho correlation coefficient. Results 24 endoscopists performed ≥ 50 colonoscopies, resulting in a total of 2889 colonoscopies. The overall ADR was 84.5 % (range 71.4 % – 95.3 %) and overall PSPDR was 13.7 % (4.3 % – 29.0 %). The sensitivity of optical diagnosis for adenomas and serrated polyps were 94.5 % (83.3 % – 100 %) and 74.0 % (37.5 % – 94.1 %), respectively. No correlation could be demonstrated between the ADR and the sensitivity of optical diagnosis for adenomas (−0.20; P = 0.35) or between the PSPDR and the sensitivity of optical diagnosis for serrated polyps (−0.12; P = 0.57). Conclusions In a homogeneous FIT-positive population, no correlation between the ADR, PSPDR, and the sensitivity of optical diagnosis for adenomas and serrated polyps could be demonstrated. These exploratory results suggest that lesion detection and differentiation require different endoscopic skills. Further prospective studies are needed; until then, monitoring of both performance indicators is important to secure optimal efficacy of FIT-based colorectal cancer screening.


2020 ◽  
Vol 7 (1) ◽  
pp. e000425
Author(s):  
Alan Gordon Fraser ◽  
Toby Rose ◽  
Philip Wong ◽  
Mark Lane ◽  
Paul Frankish

BackgroundThe audit process may help improve performance indicators for colonoscopy quality but it is unclear whether this is sustained over several years.Methods44138 procedures for 28 endoscopists from 2004 to 2019 were analysed for polyp detection rate and withdrawal time. From 2012, 14 endoscopists were analysed with additional data on polyp histology and number of polyps removed.ResultsPolyp detection increased from 40.7% in 2004 to 62.2% in 2019; removal of polyps>1 cm remained constant (11%). Adenoma detection rate was 25.8% in 2012 and 28.3% in 2019. Sessile serrated polyp (SSP) detection rate increased from 4.5% to 14.7%; most of the increase was in the first 2 years of the histology part of the audit. There was a significant correlation of adenoma detection rate with mean number of adenomas (r=0.72, p=0.004) and a significant correlation of SSP detection with mean number of SSPs (r=0.85, p=0.0001).ConclusionThe audit process appears to encourage a higher rate of polyp detection. This was due to increased detection of smaller polyps and increased detection of SSPs.


2021 ◽  
Vol 4 (Supplement_1) ◽  
pp. 97-98
Author(s):  
M Sey ◽  
B Yan ◽  
Z Hindi ◽  
M Brahmania ◽  
J C Gregor ◽  
...  

Abstract Background The use of propofol during colonoscopy has gained increased popularity due to deeper anesthesia compared to conscious sedation. Prior studies examining the use of propofol sedation during colonoscopy have primarily focused on anesthesia outcomes. Whether propofol sedation is associated with improvements in colonoscopy outcomes is uncertain. Aims The primary outcome was adenoma detection rate (ADR). Secondary outcomes were the detection of any adenoma (conventional adenoma, sessile serrated polyp, and traditional serrated adenoma), sessile serrated polyp detection rate, polyp detection rate, cecal intubation rate, and perforation rate. Methods The Southwest Ontario Colonoscopy cohort consists of all patients who underwent colonoscopy between April 2017 and Oct 2018 at 21 hospitals serving a large geographic area in Southwest Ontario. Procedures performed in patients less than 18 years of age or by endoscopist who perform <50 colonoscopies/year were excluded. Data were collected through a mandatory quality assurance form that was completed by the endoscopist after each procedure. Pathology reports were manually reviewed. Results A total of 46,634 colonoscopies were performed by 75 physicians (37.5% by gastroenterologists, 60% by general surgeons, 2.5% others) of which 16,408 (35.2%) received propofol and 30,226 (64.8%) received conscious sedation (e.g. combination of a benzodiazepine and a narcotic). Patients who received propofol were likely to have a screening indication (49.2% vs 45.5%, p<0.0001), not have a trainee endoscopist present and be performed at a non-academic centre (32.2% vs 44.6%, p<0.0001). Compared to conscious sedation, use of propofol was associated with a lower ADR (24.6% vs. 27.0%, p<0.0001) and detection of any adenoma (27.7% vs. 29.8%, p<0.0001); no difference was observed in the detection ofsessile serrated polyps (5.0% vs. 4.7%, p=0.26), polyp detection rate (41.2% vs 41.2%, p=0.978), cecal intubation rate (97.1% vs. 96.8%, p=0.15) or perforation rate (0.04% vs. 0.06%,p=0.45). On multi-variable analysis, the use of propofol was not significantly associated with any improvement in ADR (RR=0.90, 95% CI 0.74–1.10, p=0.30), detection of any adenoma (RR=0.93, 95% CI 0.75–1.14, p=0.47), sessile serrated polyp detection rate (RR=1.20, 95%CI 0.90–1.60, p=0.22), polyp detection rate (RR=1.00, 95% CI 0.90–1.11, p=0.99), or cecal intubation rate (RR=1.00, 95%CI 0.80–1.26, p=0.99). Conclusions The use of propofol sedation does not improve colonoscopy quality metrics. Funding Agencies None


BMC Cancer ◽  
2018 ◽  
Vol 18 (1) ◽  
Author(s):  
Maxime E. S. Bronzwaer ◽  
Marjolein J. E. Greuter ◽  
Arne G. C. Bleijenberg ◽  
Joep E. G. IJspeert ◽  
Evelien Dekker ◽  
...  

2020 ◽  
Vol 91 (6) ◽  
pp. AB563
Author(s):  
Sarah Stanley ◽  
Leslie Wiggins ◽  
Wiyang Szetoo ◽  
Dianne Jones ◽  
Carolyn McIvor

2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Muhammad Aziz ◽  
Tej I. Mehta ◽  
Simcha Weissman ◽  
Sachit Sharma ◽  
Rawish Fatima ◽  
...  

2019 ◽  
Vol 64 (12) ◽  
pp. 3579-3588 ◽  
Author(s):  
Maryan Cavicchi ◽  
Gaëlle Tharsis ◽  
Pascal Burtin ◽  
Philippe Cattan ◽  
Franck Venezia ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document