Large eddy simulation of turbulent flow and heat transfer in a square duct with unstable natural convection on the cross section

Author(s):  
Liang-Dong Ma ◽  
Zeng-Yao Li ◽  
Wen-Quan Tao
2016 ◽  
Vol 26 (3/4) ◽  
pp. 1069-1091 ◽  
Author(s):  
Zhou Jiang ◽  
Zuoli Xiao ◽  
Yipeng Shi ◽  
Shiyi Chen

Purpose – The knowledge about the heat transfer and flow field in the ribbed internal passage is particularly important in industrial and engineering applications. The purpose of this paper is to identify and analyze the performance of the constrained large-eddy simulation (CLES) method in predicting the fully developed turbulent flow and heat transfer in a stationary periodic square duct with two-side ribbed walls. Design/methodology/approach – The rib height-to-duct hydraulic diameter ratio is 0.1 and the rib pitch-to-height ratio is 9. The bulk Reynolds number is set to 30,000, and the bulk Mach number of the flow is chosen as 0.1 in order to keep the flow almost incompressible. The CLES calculated results are thoroughly assessed in comparison with the detached-eddy simulation (DES) and traditional large-eddy simulation (LES) methods in the light of the experimentally measured data. Findings – It is manifested that the CLES approach can predict both aerodynamic and thermodynamic quantities more accurately than the DES and traditional LES methods. Originality/value – This is the first time for the CLES method to be applied to simulation of heat and fluid flow in this widely used geometry.


Author(s):  
Aroon K. Viswanathan ◽  
Danesh K. Tafti

Results from Large Eddy Simulation (LES) of fully developed flow in a ribbed duct are presented with rib pitch-to-height ratio (P/e) is 10 and a rib height to hydraulic diameter ratio (e/Dh) is 0.1. Computations are carried out on a square duct with 45° ribs on the top and bottom walls arranged in a staggered fashion. The ribs have a rounded cross-section and are skewed at 45° to the main flow. The Reynolds number based on bulk velocity is 25,000. Mean flow and turbulent quantities, together with heat transfer and friction augmentation results are presented for a stationary case. The flow is characterized by a helical vortex behind each rib and a complementary cross-sectional secondary flow, both of which result from the angle of the rib with respect to the mean flow and result in a spanwise variation of the heat transfer. The mean flow, the turbulent quantities and the heat transfer in the duct show similar trends as in the duct with square cross-section ribs. However the results show that there is lesser friction in the ducts with rounded ribs. The overall heat transfer on the ribbed wall was augmented by 2.85 times that of a smooth duct, at the cost of friction which increases by a factor of 10. The computed values compare well with the experimental values.


Sign in / Sign up

Export Citation Format

Share Document