scholarly journals Spinal anesthesia performed for cesarean delivery after external ventricular drain placement in a parturient with symptomatology from an intracranial mass

2019 ◽  
Vol 37 ◽  
pp. 122-125 ◽  
Author(s):  
M. Reschke ◽  
J.M. Sweeney ◽  
N. Wong
2020 ◽  
Vol 5 (3) ◽  
pp. 1241-1245
Author(s):  
Kumud Pyakurel ◽  
Lalit Kumar Rajbanshi ◽  
Ramesh Bhattarai ◽  
Sonia Dahal

Introduction: Spinal anesthesia induced hypotension frequently complicates Cesarean delivery. This is usually due to sudden sympatholysis causing decreased venous return which can be aggravated by physiological changes of pregnancy leading to change in baseline peripheral vascular tone. Strategies to prevent hypotensive episodes should be the primary aim of anesthetic management. A simple noninvasive measurement of perfusion index derived from pulse oximeter predicting hypotension during the routine intraoperative course could provide a new dynamism to the management and improving the safe execution of anesthesia. Objectives: The primary objective of this study was to compare incidence of hypotension following SAB for LSCS in patients with baseline PI ≤ 3.5 to those with PI > 3.5. The secondary objectives were to compare PI, HR, SBP, MAP at various time intervals and also to study the side effects between the two groups. Methodology: This prospective observational study was conducted at Nobel Medical College Teaching Hospital from to July 2019 to October 2019. 73 Term parturients presenting for elective cesarean delivery were included for the study. Upon arrival in the operation room, standard monitors were attached and baseline HR, SBP, DBP, MAP, PI and SPO2 were recorded in supine position. The patients with baseline PI ≤ 3.5 were enrolled into Group I and those with a PI > 3.5 were enrolled into Group II. Spinal Anesthesia with 10mg of 0.5% heavy Bupivacaine and 20mcg Fentanyl ( total 2.4ml) was given at L3-L4 interspace in sitting position using midline approach. Patient was then returned to supine position with left lateral tilt of 15 degrees to facilitate left uterine displacement. Upper sensory level was checked at 5 minutes using alcohol swab. Once T-6 level was reached, surgery was started. Maternal SBP, DBP, MAP, HR and PI were recorded at 1 minute intervals between spinal injection and delivery and then 3 minutes until end of surgery. Clinically relevant hypotension was defined as the decrease in MAP by 20% or more from baseline value. Results: The incidence of hypotension in Group I was 18.8% (6/30) compared to 81.3% (26/38). This was clinically and statistically highly significant (P = 0.000, odds ratio 0.11). On Spearman’s rank correlation we found highly significant correlation between baseline PI >3.5 and number of episodes of hypotension (rs 0.482, P = 0.000). The sensitivity and specificity of baseline PI with cut-off 3.5 for predicting hypotension were 81.3% and 66.7% respectively. The ROC curve analysis showed 3.53 as appropriate cut‑off for our findings. The area under the ROC curve (AUC) was 0.734 [Figure 6](Lower bound 0.608 and upper bound 0.861, P=0.001).  Conclusion : This study demonstrates that baseline PI of > 3.5 correlates with incidence of hypotension after spinal anesthesia for cesarean delivery in healthy parturients compared to a baseline PI of < 3.5.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Shi-Fa Yao ◽  
Yan-Hong Zhao ◽  
Jing Zheng ◽  
Jie-Yan Qian ◽  
Chen Zhang ◽  
...  

Abstract Background Post-spinal anesthesia hypotension during cesarean delivery is caused by decreased systemic vascular resistance due to the blockage of the autonomic nerves, which is further worsened by inferior vena cava (IVC) compression by the gravid uterus. This study aimed to assess whether peak velocity and diameter of the IVC below the xiphoid or right common femoral vein (RCFV) in the inguinal region, as measured on ultrasound, could reflect the degree of IVC compression and further identify parturients at risk of post-spinal hypotension. Methods Fifty-six parturients who underwent elective cesarean section with spinal anesthesia were included in this study; peak velocities and anteroposterior diameters of the IVC and peak velocities and transverse diameters of the RCFV were measured using ultrasound before anesthesia. The primary outcome was the ultrasound measurements of IVC and RCFV acquired before spinal anesthesia and their association with post-spinal hypotension. Hypotension was defined as a drop in systolic arterial pressure by > 20% from the baseline. Multinomial logistic regression analysis was used to identify the association between the measurements of IVC, RCFV, and post-spinal hypotension during cesarean delivery. Receiver operating characteristic curves were used to test the abilities of the identified parameters to predict post-spinal hypotension; the areas under the curve and optimum cut-off values for the predictive parameters were calculated. Results A longer transverse diameter of the RCFV was associated with the occurrence of post-spinal hypotension (odds ratio = 2.022, 95% confidence interval [CI] 1.261–3.243). The area under the receiver operating characteristics curve for the prediction of post-spinal hypotension was 0.759 (95% CI 0.628–0.890, P = 0.001). A transverse diameter of > 12.2 mm of the RCFV could predict post-spinal hypotension during cesarean delivery. Conclusions A longer transverse diameter of RCFV was associated with hypotension and could predict parturients at a major risk of hypotension before anesthesia. Trial registration This study was registered at http://www.chictr.org.cn on 16, May, 2018. No. ChiCTR1800016163.


Sign in / Sign up

Export Citation Format

Share Document