scholarly journals TCT-756 Incidence of Patient Prosthesis Mismatch Following Native and Valve-in-Valve Transcatheter Aortic Valve Replacement Based on Indexed Aortic Valve Area Compared to Energy Loss Index

2019 ◽  
Vol 74 (13) ◽  
pp. B742
Author(s):  
Ramy Mando ◽  
George Hanzel ◽  
Michael Gallagher ◽  
Robert Safian ◽  
Safwan Kassas ◽  
...  
2020 ◽  
Vol 21 (10) ◽  
pp. 1092-1102 ◽  
Author(s):  
Erik W Holy ◽  
Thi Dan Linh Nguyen-Kim ◽  
Lisa Hoffelner ◽  
Daniel Stocker ◽  
Thomas Stadler ◽  
...  

Abstract Aims  To assess whether the combination of transthoracic echocardiography (TTE) and multidetector computed tomography (MDCT) data affects the grading of aortic stenosis (AS) severity under consideration of the energy loss index (ELI) in patients undergoing transcatheter aortic valve replacement (TAVR). Methods and results  Multimodality imaging was performed in 197 patients with symptomatic severe AS undergoing TAVR at the University Hospital Zurich, Switzerland. Fusion aortic valve area index (fusion AVAi) assessed by integrating MDCT derived planimetric left ventricular outflow tract area into the continuity equation was significantly larger as compared to conventional AVAi (0.41 ± 0.1 vs. 0.51 ± 0.1 cm2/m2; P < 0.01). A total of 62 patients (31.4%) were reclassified from severe to moderate AS with fusion AVAi being >0.6 cm2/m2. ELI was obtained for conventional AVAi and fusion AVAi based on sinotubular junction area determined by TTE (ELILTL 0.47 ± 0.1 cm2/m2; fusion ELILTL 0.60 ± 0.1 cm2/m2) and MDCT (ELIMDCT 0.48 ± 0.1 cm2/m2; fusion ELIMDCT 0.61 ± 0.05 cm2/m2). When ELI was calculated with fusion AVAi the effective orifice area was >0.6 cm2/m2 in 85 patients (43.1%). Survival rate 3 years after TAVR was higher in patients reclassified to moderate AS according to multimodality imaging derived ELI (78.8% vs. 67%; P = 0.01). Conclusion  Multimodality imaging derived ELI reclassifies AS severity in 43% undergoing TAVR and predicts mid-term outcome.


2020 ◽  
Vol 13 (21) ◽  
pp. 2584-2586
Author(s):  
Taishi Okuno ◽  
Thomas Pilgrim ◽  
Dik Heg ◽  
Stefan Stortecky ◽  
Fabien Praz ◽  
...  

2021 ◽  
Vol 14 (2) ◽  
pp. 211-220 ◽  
Author(s):  
Michel Pompeu B.O. Sá ◽  
Jef Van den Eynde ◽  
Matheus Simonato ◽  
Luiz Rafael P. Cavalcanti ◽  
Ilias P. Doulamis ◽  
...  

2021 ◽  
Vol 5 (5) ◽  
Author(s):  
Klaus-Dieter Hönemann ◽  
Steffen Hofmann ◽  
Frank Ritter ◽  
Gerold Mönnig

Abstract Background A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). Case summary We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. Discussion We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.


Author(s):  
Taishi Okuno ◽  
Noé Corpataux ◽  
Giancarlo Spano ◽  
Christoph Gräni ◽  
Dik Heg ◽  
...  

Abstract Aims The ESC/EACTS guidelines propose criteria that determine the likelihood of true-severe aortic stenosis (AS). We aimed to investigate the impact of the guideline-based criteria of the likelihood of true-severe AS in patients with low-flow low-gradient (LFLG) AS with preserved ejection fraction (pEF) on outcomes following transcatheter aortic valve replacement (TAVR). Methods and results In a prospective TAVR registry, LFLG-AS patients with pEF were retrospectively categorized into high (criteria ≥6) and intermediate (criteria <6) likelihood of true-severe AS. Haemodynamic, functional, and clinical outcomes were compared with high-gradient AS patients with pEF. Among 632 eligible patients, 202 fulfilled diagnostic criteria for LFLG-AS. Significant haemodynamic improvement after TAVR was observed in LFLG-AS patients, irrespective of the likelihood. Although >70% of LFLG-AS patients had functional improvement, impaired functional status [New York Heart Association (NYHA III/IV)] persisted more frequently at 1 year in LFLG-AS than in high-gradient AS patients (7.8%), irrespective of the likelihood (high: 17.4%, P = 0.006; intermediate: 21.1%, P < 0.001). All-cause death at 1 year occurred in 6.6% of high-gradient AS patients, 10.9% of LFLG-AS patients with high likelihood [hazard ratio (HR)adj 1.43, 95% confidence interval (CI) 0.68–3.02], and in 7.2% of those with intermediate likelihood (HRadj 0.92, 95% CI 0.39–2.18). Among the criteria, only the absence of aortic valve area ≤0.8 cm2 emerged as an independent predictor of treatment futility, a combined endpoint of all-cause death or NYHA III/IV at 1 year (OR 2.70, 95% CI 1.14–6.25). Conclusion Patients with LFLG-AS with pEF had comparable survival but worse functional status at 1 year than high-gradient AS with pEF, irrespective of the likelihood of true-severe AS. Clinical Trial Registration https://www.clinicaltrials.gov. NCT01368250.