In Vivo Detection of Subtle Vertical Root Fracture in Endodontically Treated Teeth by Cone-beam Computed Tomography

2019 ◽  
Vol 45 (7) ◽  
pp. 856-862 ◽  
Author(s):  
Lei Zhang ◽  
Tiemei Wang ◽  
Ya Cao ◽  
Congyue Wang ◽  
Baochun Tan ◽  
...  
2020 ◽  
Vol 46 (8) ◽  
pp. 1059-1066 ◽  
Author(s):  
Debora R. Dias ◽  
Lilian C.V. Iwaki ◽  
Alexandre C.A. de Oliveira ◽  
Felipe S. Martinhão ◽  
Robson M. Rossi ◽  
...  

2014 ◽  
Vol 44 (1) ◽  
pp. 37 ◽  
Author(s):  
Ehsan Moudi ◽  
Sina Haghanifar ◽  
Zahrasadat Madani ◽  
Abdolhamid Alhavaz ◽  
Ali Bijani ◽  
...  

2017 ◽  
Vol 18 (2) ◽  
pp. 94-99 ◽  
Author(s):  
Ricardo Raitz ◽  
Mariana Tiepo ◽  
Gabriel Magrin ◽  
Ana C Kovalik ◽  
Belkiss Marmora ◽  
...  

ABSTRACT Aim Our objective was to perform an in vitro evaluation of root fracture in endodontically treated teeth using two cone beam computed tomography (CBCT) machines. Materials and methods The sample comprised 86 singlerooted human premolars that had been fractured by a universal testing machine. The tomographic images were acquired using an Orthopantomograph OP300® and an Orthophos XG 3D® and evaluated by three examiners, by means of specific software. The teeth were classified into presence or absence of root fracture, then the root third where the fracture occurred, was determined. With regard to the detection of the fracture, the Kappa statistic was used for intra and interexaminer reproducibility at two distinct points in time. Chi-squared test was employed to analyze the sensitivity and specificity of the two tomographs (p < 0.05). Results The results showed a good or excellent Kappa index between examiners. As for the absolute frequency, the sensitivity (0.6) of the Orthophos XG 3D® equipment was superior, while specificity (0.91) was higher with the Orthopantomograph OP300®. On the receiver operating characteristics curve, moderate performance was found with an accuracy of 0.73 (OrthopantomographOP300®) and 0.74 (Orthophos XG 3D®) respectively. As far as the location of the root fracture is concerned, moderate agreement was verified using the Kappa statistic (k = 0.56). Conclusion Although the regular CBCTs represent the imaging examination of choice for assisting root fracture diagnosis in endodontically treated teeth, their performance in this study demonstrated an imprecise diagnosis of fractures in a good many cases, irrespective of the tomography machine used. Clinical significance An early and precise detection of root fractures is of the utmost clinical importance, but the radiopaque and/or metallic filling materials in the CBCT viewing field may generate artifacts, known as the beam-hardening effect, which could compromise root fracture detection. How to cite this article Tiepo M, Magrin G, Kovalik AC, Marmora B, Silva MF, Raitz R. Evaluation of Root Fracture in endodontically treated Teeth using Cone Beam Computed Tomography. J Contemp Dent Pract 2017;18(2):94-99.


2017 ◽  
Vol 43 (7) ◽  
pp. 1170-1175 ◽  
Author(s):  
Kamile Leonardi Dutra ◽  
Camila Pachêco-Pereira ◽  
Eduardo Antunes Bortoluzzi ◽  
Carlos Flores-Mir ◽  
Manuel O. Lagravère ◽  
...  

2018 ◽  
Vol 44 (7) ◽  
pp. 1168-1172 ◽  
Author(s):  
Victor Aquino Wanderley ◽  
Deborah Queiroz Freitas ◽  
Francisco Haiter-Neto ◽  
Matheus Lima Oliveira

Sign in / Sign up

Export Citation Format

Share Document