A numerical study on utilizing horizontal flat-panel ground heat exchangers in ground-coupled heat pumps

2020 ◽  
Vol 147 ◽  
pp. 996-1010 ◽  
Author(s):  
Mohammad Habibi ◽  
Ali Amadeh ◽  
Ali Hakkaki-Fard
Author(s):  
Yuefen Gao ◽  
Songling Wang ◽  
Guoqiang Zhang

Ground-coupled heat pump systems use the ground as a heat source and sink either with vertical or horizontal ground heat exchangers (GHXs) to supply heating in winter and cooling in summer. The ground heat source and sink has a near constant temperature, which is well suited to ground-coupled heat pumps, giving them consistent performance, regardless of the outdoor temperature. However, when the heat extracted from and rejected to the ground has great imbalance, the ground temperature will deviate from the original temperature with a long term operation. The deviation can reduce GHX performance greatly. As China has vast territory with variety climate, the annual cooling loads and heating loads are different at different places. And the imbalance between the extracted heat and the rejected heat also varies at different places. Therefore, it is necessary to analysis the regional suitability of the ground-coupled heat pump systems. The imbalance between the extracted heat and the rejected heat is analyzed by taking several typical cities in different climates. The new concepts of the Imbalance Ratio and the Extracted Heat to Rejected Heat Ratio are introduced as the weight factors to measure the imbalance in the ground. The values of the Imbalance Ratio and those of the Extracted Heat to the Rejected Heat Ratio are calculated. The optimum range of the Imbalance Ratio is recommended based on the vast investigation of the ground-coupled heat pumps. Some supplemental systems are put forward to supply heat in winter or to reject heat in summer at the places existing serious heat imbalance. The study is very meaningful to the scientific application of the ground-coupled heat pump systems in China.


2018 ◽  
Vol 44 ◽  
pp. 00157
Author(s):  
Piotr Rynkowski

The paper presents the ground temperature analysis, heat flows and energy transferred from the soil massif by the vertical ground heat exchangers (VGHE). Three cases – with one, two and three vertical heat exchangers were compared. Their influences on the soil massif temperature in the heat exchangers area were shown. The mass flow and the temperature at the inlet and outlet side of the heat pump were measured in each circuit. Additional, the electricity consumption by the heat pump and energy supply to buffer vessel were measured. Finally, the Coefficient of Performance (COP) as a function of length of VGHE is shown for selected interval time.


2016 ◽  
Vol 95 ◽  
pp. 561-573 ◽  
Author(s):  
Salsuwanda Selamat ◽  
Akio Miyara ◽  
Keishi Kariya

Sign in / Sign up

Export Citation Format

Share Document