TRANSCATHETER PATENT DUCTUS ARTERIOSUS (PDA) CLOSURE IN LOWER WEIGHT INFANTS (<6KG): MID- AND LONG-TERM FOLLOW-UP

2018 ◽  
Vol 71 (11) ◽  
pp. A577
Author(s):  
Erin Nealon ◽  
Corey Stiver ◽  
Clifford Cua ◽  
Claire Mitchell ◽  
Brian Boe ◽  
...  
2012 ◽  
Vol 8 (2) ◽  
pp. 159-166 ◽  
Author(s):  
Fadli Demir ◽  
Ahmet Celebi ◽  
Turkay Saritas ◽  
Abdullah Erdem ◽  
Halil Demir ◽  
...  

2003 ◽  
Vol 44 (11) ◽  
pp. 480-490 ◽  
Author(s):  
N. Van Israel ◽  
J. Dukes-McEwan ◽  
A. T. French

2001 ◽  
Vol 88 (5) ◽  
pp. 586-588 ◽  
Author(s):  
Roberto Formigari ◽  
Alessandra Toscano ◽  
Ignacio Herraiz ◽  
Jacek Bialkowski ◽  
Andrea Donti ◽  
...  

2019 ◽  
Vol 212 ◽  
pp. 144-150.e3 ◽  
Author(s):  
Erin Nealon ◽  
Brian K. Rivera ◽  
Clifford L. Cua ◽  
Molly K. Ball ◽  
Corey Stiver ◽  
...  

Author(s):  
Dor Markush ◽  
Jennifer C. Tsing ◽  
Surbhi Gupta ◽  
Nicole C. Berndsen ◽  
Geena Radville ◽  
...  

AbstractTranscatheter patent ductus arteriosus closure (TCPC) is an emerging treatment for low birth weight extremely premature neonates (EPNs). Left pulmonary artery (LPA) and descending aorta (DAO) obstruction are described device-related complications, however, data on mid- and long-term vascular outcomes are lacking. A retrospective analysis of EPNs who underwent successful TCPC at our institution from 03/2013 to 12/2018 was performed. Two-dimensional echocardiography and spectral Doppler velocities from various time points before and after TCPC were used to identify LPA and DAO flow disturbances. A total of 44 EPNs underwent successful TCPC at a median (range) procedural weight of 1150 g (755–2500 g). Thirty-two (73%) patients were closed with the AVP II and 12 (27%) with the Amplatzer Piccolo device. LPA and DAO velocities on average remained within normal limits and improved spontaneously in long-term follow up (26.1 months, range 1–75 months). One patient, who had concerning LPA flow characteristics immediately after device implant (peak velocity 2.6 m/s) developed progressive LPA stenosis requiring stent placement 3 months post-procedure. In the remaining infants, including 7 (16%) who developed LPA and 3 (7%) who developed DAO flow disturbances (range 2–2.4 m/s), all had progressive normalization of flow velocities over time. TCPC can be performed safely in EPNs with a low incidence of LPA and DAO obstruction. In the absence of significant progressive vascular obstruction in the early post-procedure period, mild increases in LPA and DAO flow velocities tend to improve spontaneously and normalize in long-term follow-up.


Sign in / Sign up

Export Citation Format

Share Document