scholarly journals Diagnostic yield of endoscopic ultrasound-guided tissue acquisition in autoimmune pancreatitis: a systematic review and meta-analysis

2021 ◽  
Vol 09 (01) ◽  
pp. E66-E75
Author(s):  
Antonio Facciorusso ◽  
Luca Barresi ◽  
Renato Cannizzaro ◽  
Filippo Antonini ◽  
Konstantinos Triantafyllou ◽  
...  

Abstract Background and study aims There is limited evidence on the diagnostic performance of endoscopic ultrasound (EUS)-guided tissue acquisition in autoimmune pancreatitis (AIP). The aim of this meta-analysis was to provide a pooled estimate of the diagnostic performance of EUS-guided fine-needle aspiration (FNA) and fine-needle biopsy (FNB) in patients with AIP. Patients and methods Computerized bibliographic search was performed through January 2020. Pooled effects were calculated using a random-effects model by means of DerSimonian and Laird test. Primary endpoint was diagnostic accuracy compared to clinical diagnostic criteria. Additional outcomes were definitive histopathology, pooled rates of adequate material for histological diagnosis, sample adequacy, mean number of needle passes. Diagnostic sensitivity and safety data were also analyzed. Results Fifteen studies with 631 patients were included, of which four were prospective series and one randomized trial. Overall diagnostic accuracy of EUS tissue acquisition was 54.7 % (95 % confidence interval, 40.9 %–68.4 %), with a clear superiority of FNB over FNA (63 %, 52.7 % to 73.4 % versus 45.7 %, 26.5 %–65 %; p < 0.001). FNB provided level 1 of histological diagnosis in 44.2 % of cases (30.8 %–57.5 %) as compared to 21.9 % (10 %–33.7 %) with FNA (P < 0.001). The rate of definitive histopathology of EUS tissue sampling was 20.7 % (12.9 %–28.5 %) and it was significantly higher with FNB (24.3 %, 11.8 %–36.8 %) as compared to FNA (14.7 %, 5.4 %–23.9 %; P < 0.001). Less than 1 % of subjects experienced post-procedural acute pancreatitis. Conclusion The results of this meta-analysis demonstrate that the diagnostic performance of EUS-guided tissue acquisition is modest in patients with AIP, with an improved performance of FNB compared to FNA.

2019 ◽  
Vol 07 (10) ◽  
pp. E1221-E1230 ◽  
Author(s):  
Antonio Facciorusso ◽  
Valentina Del Prete ◽  
Vincenzo Rosario Buccino ◽  
Purvi Purohit ◽  
Puneet Setia ◽  
...  

Abstract Background and study aims Although newer needle designs are thought to improve diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy, there is limited evidence on their diagnostic performance. The aim of this meta-analysis was to provide a pooled estimate of the diagnostic performance and safety profile of Franseen and Fork-tip fine-needle biopsy needles. Patients and methods Computerized bibliographic search on the main databases was performed through March 2019. The primary endpoint was sample adequacy. Secondary outcomes were diagnostic accuracy, optimal histological core procurement, mean number of needle passes, pooled specificity and sensitivity. Safety data were also analyzed. Results Twenty-four studies with 6641 patients were included and pancreas was the prevalent location of sampled lesions. Overall sample adequacy with the two newer needles was 94.8 % (93.1 % – 96.4 %), with superiority of Franseen needle over Fork-tip (96.1 % versus 92.4 %, P < 0.001). Sample adequacy in targeting pancreatic masses was 95.6% and both needles produced results superior to fine-needle aspiration (FNA) (odds ratio 4.29, 1.49 – 12.35 and 1.79, 1.01 – 3.19 with Franseen and Fork-tip needle, respectively). The rate of histological core procurement was 92.5%, whereas diagnostic accuracy and sensitivity were 95 % and 92.8 %, again with no difference between the two needles. Number of needle passes was significantly lower in comparison to FNA (mean difference: –0.42 with Franseen and –1.60 with Fork-tip needle). No significant adverse events were registered. Conclusion Our meta-analysis speaks in favor of use of newer biopsy needles as a safe and effective tool in endoscopic ultrasound-guided tissue acquisition.


2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Lachlan R. Ayres ◽  
Elizabeth K. Kmiotek ◽  
Eric Lam ◽  
Jennifer J. Telford

Background and Aims. Endoscopic ultrasound (EUS) guided fine-needle aspiration (FNA) is the method of choice for sampling pancreatic lesions. This study compares the diagnostic accuracy and safety of FNB using a novel core needle to FNA in solid pancreatic lesions. Methods. A retrospective review of patients in whom EUS FNA or FNB was performed for solid pancreatic lesions was conducted. Diagnostic performance was calculated based upon a dual classification system: classification 1, only malignant pathology considered a true positive, versus classification 2, atypical, suspicious, and malignant pathology considered a true positive. Results. 43 patients underwent FNB compared with 51 FNA. Using classification 1, sensitivity was 74.0% versus 80.0%, specificity 100% versus 100%, and diagnostic accuracy 77.0% versus 80.0% for FNB versus FNA, respectively (all p>0.05). Using classification 2, sensitivity was 97% versus 94.0%, specificity 100% versus 100%, and diagnostic accuracy 98.0% versus 94.0% for FNB versus FNA, respectively (all p>0.05). FNB required significantly fewer needle passes (median = 2) compared to FNA (median = 3; p<0.001). Adverse events occurred in two (4.5%) FNB patients compared with none in the FNA group (p>0.05). Conclusion. FNA and FNB have comparable sensitivity and diagnostic accuracy. FNB required fewer passes.


Trials ◽  
2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Masahiro Itonaga ◽  
Satoru Yasukawa ◽  
Toshio Shimokawa ◽  
Mamoru Takenaka ◽  
Nobuyasu Fukutake ◽  
...  

Abstract Background Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) was developed with the aim of further improving the diagnostic performance of endoscopic ultrasound. Although novel puncture needles have been specifically designed for collecting sufficient tissue specimens, clinical studies have indicated no clear difference in diagnostic performance between these novel needles and conventional puncture needles. Recently, a needle with Franseen geometry was developed specifically for EUS-FNA biopsy. Due to the characteristic shape of its tip, the Franseen needle is expected to be effective for scraping tissues, thus potentially increasing the diagnostic accuracy of EUS-FNA biopsy. We plan to carry out a prospective, multicenter, open-labeled, controlled trial to compare conventional and Franseen needles in terms of the diagnostic accuracy of EUS-FNA for evaluating the malignancy of pancreatic mass lesions. Methods/design The study will enroll 520 patients with pancreatic mass managed at any of 21 participating endoscopic centers. Lesion samples obtained using 22G conventional and Franseen needles will be assessed to compare the efficacy and safety of these two types of needles in EUS-FNA for evaluating the malignancy of mass lesions in the pancreas. Tissue samples will be fixed in formalin and processed for histologic evaluation. For the purpose of this study, only samples obtained with the first needle pass will be used for comparing the: (i) accuracy of the malignancy diagnosis, (ii) sensitivity and specificity for the malignancy diagnosis, (iii) procedure completion rate, (iv) sample cellularity, and (v) incidence of complications. Patient enrollment begins on July 17, 2018. Discussion The outcomes of this study may provide insight into the optimal needle choice for evaluating the malignancy of pancreatic solid lesions, thus aiding in the development of practice guidelines for pancreatic diseases. Trial registration University Hospital Medical Information Network Clinical Trials Registry (UMIN-CTR), UMIN000030634. Registered on 29 December 2017. http://www.umin.ac.jp/ Version number: 01.2017.12.28.


2019 ◽  
Author(s):  
Masahiro Itonaga ◽  
Satoru Yasukawa ◽  
Toshio Shimokawa ◽  
Mamoru Takenaka ◽  
Nobuyasu Fukutake ◽  
...  

Abstract Background Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) was developed with the aim of further improving the diagnostic performance of endoscopic ultrasound. Although novel puncture needles have been specifically designed for collecting sufficient tissue specimens, clinical studies have indicated no clear difference in diagnostic performance between these novel needles and conventional puncture needles. Recently, a needle with Franseen geometry was developed specifically for EUS-FNA biopsy. Due to the characteristic shape of its tip, the Franseen needle is expected to be effective for scraping tissues, thus potentially increasing the diagnostic accuracy of EUS-FNA biopsy. We plan to carry out a prospective, multicenter, open-labeled, controlled trial to compare conventional and Franseen needles in terms of the diagnostic accuracy of EUS-FNA for evaluating the malignancy of pancreatic mass lesions. Methods/design The study will enroll 520 patients with pancreatic mass managed at any of 21 participating endoscopic centers. Lesion samples obtained using 22G conventional and Franseen needles will be assessed to compare the efficacy and safety of these two types of needles in EUS-FNA for evaluating the malignancy of mass lesions in the pancreas. Tissue samples will be fixed in formalin and processed for histologic evaluation. For the purpose of this study, only samples obtained with the first needle pass will be used for comparing the: (i) accuracy of the malignancy diagnosis, (ii) sensitivity and specificity for the malignancy diagnosis, (iii) procedure completion rate, (iv) sample cellularity, and (v) incidence of complications. Discussion The outcomes of this study may provide insight into the optimal needle choice for evaluating the malignancy of pancreatic solid lesions, thus aiding in the development of practice guidelines for pancreatic diseases.


2020 ◽  
pp. 155335062092532
Author(s):  
Yan Luk ◽  
Wong Hoi She ◽  
Felix Che Lok Chow ◽  
Ka Wing Ma ◽  
Simon Hing Yin Tsang ◽  
...  

Background. Endoscopic ultrasound (EUS) and fine-needle aspiration (FNA) are commonly used for assessing pancreatic lesions. This study aimed to evaluate the diagnostic yield and accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in a single tertiary institution. Methods. Consecutive patients who underwent EUS-FNA of the pancreas at Queen Mary Hospital, Hong Kong, from January 2015 to March 2016 were retrospectively reviewed. Endoscopic findings and FNA results were analysed. For patients who subsequently underwent surgical resection of pancreatic lesion, EUS-FNA diagnoses were compared to histopathological findings of surgical specimens to determine its diagnostic accuracy. Results. One hundred twelve EUS-FNA were performed in 99 patients within the study time period and were included for analysis. Sixty-six (66.7%) pancreatic lesions were solid in nature and 33 (33.3%) were cystic. The overall diagnostic yield of EUS-FNA was 70.5% (n = 79). On multivariate analysis, more passes of needle were associated with a higher diagnostic yield (odds ratio = 2.000, P = .049). 57.1% (n = 64) of EUS-FNA results had an impact on management. Sixteen patients with diagnostic EUS-FNA subsequently underwent surgery for resection of the pancreatic lesion. Upon correlation to the histopathological findings of surgical specimens, there were 12 true-positive, 2 true-negative, 0 false-positive, and 2 false-negative cases. Sensitivity was 85.7%, specificity was 100%, positive predictive value was 100%, and negative predictive value was 50%. The diagnostic accuracy of EUS-FNA was 87.5%. Conclusion. EUS-FNA is accurate and reliable for diagnosing pancreatic lesions.


Sign in / Sign up

Export Citation Format

Share Document