Background/need. The increases in reference images and information during bronchoscopy using virtual bronchoscopic navigation (VBN) and fluoroscopy has potentially created the need for support using a head-mounted display (HMD) because bronchoscopists feel difficulty to see displays that are at a distance from them and turn their head and body in various directions. Methodology and device description. The binocular see-through Moverio BT-35E Smart Glasses can be connected via a high-definition multimedia interface and have a 720p high-definition display. We developed a system that converts fluoroscopic (live and reference), VBN, and bronchoscopic image signals through a converter and references them using the Moverio BT-35E. Preliminary results. We performed a virtual bronchoscopy-guided transbronchial biopsy simulation using the system. Four experienced pulmonologists performed a simulated bronchoscopy of 5 cases each with the Moverio BT-35E glasses, using bronchoscopy training model. For all procedures, the bronchoscope was advanced successfully into the target bronchus according to the VBN image. None of the operators reported eye or body fatigue during or after the procedure. Current status. This small-scale simulation study suggests the feasibility of using a HMD during bronchoscopy. For clinical use, it is necessary to evaluate the safety and usefulness of the system in larger clinical trials in the future.


2022 ◽  
pp. 155335062110664
Author(s):  
Eleftherios Zachariou ◽  
Athanasios Galanis ◽  
Evangelos Mavrommatis

Edward Hickling Bradford (1848-1926) is considered as 1 of the most important figures in American and world orthopedics during 19th and early 20th century. His teaching ability, his gifted surgical skills and his innovations in orthopedics attracted the interest of the world orthopedic’s community and gave him a long lasting reputation. But most of all he is considered as the founder of pediatric orthopedics in America.


2021 ◽  
pp. 155335062110624
Author(s):  
Hojat Layeg ◽  
Vahide K. Meshki ◽  
Mohammad Y. Karami ◽  
Seyed Amin Moosavi ◽  
Ehsan Kafili ◽  
...  

Background Anastomotic leak (AL) is one of the most important postoperative complications after hemicolectomy with stapled anastomosis. This study aimed to evaluate the association of preoperative vitamin D3 with early anastomotic leakage after right colon cancer surgery with stapled anastomosis. Method In this prospective cohort study, 535 patients who underwent right colon cancer surgery (right hemicolectomy) with stapled anastomosis were enrolled. A subset of 315 patients was included in the study after meeting the inclusion criteria. Preoperative vitamin D level was measured and analyzed for association with early AL using univariable and multivariable logistic regression analyses. Result This study included 315 cases; among them, 18 (5.71%) patients developed early AL. Vitamin D3 was significantly higher among patients without early AL ( P < .001). Low vitamin D3 status was reported among 111 patients (35.2%) and 204 (64.8%) of patients did not have low vitamin D3 status (sufficient level = 30-100 ng/mL). Sufficient vitamin D3 levels before right colon cancer surgery with stapled anastomosis was associated inversely with early AL (crude OR = .89, 95% CI = .85-.94, P < .001 and adjusted OR = .89, 95% CI = .82-.98, P = .02). Conclusion The vitamin D3 level has a protective association with early AL. As a result, low vitamin D3 status may be a risk factor for early AL development, suggesting that it can be one of the predictors of early AL occurrence.


2021 ◽  
pp. 155335062110658
Author(s):  
Amir A. Hakimi ◽  
Dana M. Hutchison ◽  
Asher Park ◽  
Natasha Atanaskova Mesinkovska ◽  
Sehwan Kim ◽  
...  

Background. Droplet simulation often requires expensive and inaccessible equipment. Herein, we develop and assess a low-cost droplet simulation model using easily accessible materials, open-source software, and a smartphone-based cobalt blue light. Methods. The simulation model was developed using commercial-grade materials and fluorescein dye. A clear face shield was assessed ten times following a simulated cough using fluorescein dye. A conventional ultraviolet Woods lamp was compared to a smartphone-based cobalt blue light to detect fluorescein illumination. Results. The simulation platform and smartphone-based cobalt blue light cost $20.18. A Wilcoxon signed rank test revealed that the median droplet area of fluorescence under the UV Wood’s lamp was not significantly different than that of the smartphone-based cobalt blue light (2.89 vs 2.94, P = .386). Conclusions. This simulation model is inexpensive and easily reproducible. The smartphone application may be a convenient alternative to standard ultraviolet lights. This model has great potential for use in financially restricted academic centers during the COVID-19 pandemic and beyond.


2021 ◽  
pp. 155335062110624
Author(s):  
Jing Yang ◽  
Penghui Ni ◽  
Lina Zhang ◽  
Zhanxin Lu ◽  
Dapeng Liu ◽  
...  

Background This study aimed to evaluate a personalized 3D-printed percutaneous vertebroplasty positioning module and navigation template based on preoperative CT scan data that was designed to treat patients with vertebral compression fractures caused by osteoporosis. Methods A total of 22 patients with vertebral compression fractures admitted to our hospital were included in the study. Positioning was performed with the new 3D-printed positioning module, and the navigation template was used for patients in the experimental group, and the traditional perspective method was used for patients in the control group. The experimental group consisted of 11 patients, 2 males and 9 females, with a mean age of 67.27 ± 11.86 years (range: 48 to 80 years), and the control group consisted of 11 patients, 3 males and 8 females, with a mean age of 74.27 ± 7.24 years (range: 63 to 89 years). The puncture positioning duration, number of intraoperative fluoroscopy sessions, and preoperative and postoperative visual analog scale (VAS) scores were statistically analyzed in both groups. Results The experimental group had shorter puncture positioning durations and fewer intraoperative fluoroscopy sessions than the control group, and the differences were statistically significant (P < .05). There were no significant differences in age or preoperative or postoperative VAS scores between the two groups (P > .05). Conclusions The new 3D-printed vertebroplasty positioning module and navigation template shortened the operation time and reduced the number of intraoperative fluoroscopy sessions. It also reduced the difficulty in performing percutaneous vertebroplasty and influenced the learning curve of senior doctors learning this operation to a certain degree.


2021 ◽  
pp. 155335062110641
Author(s):  
Olga D. Savvidou ◽  
Panayiotis D. Megaloikonomos ◽  
Asimina Vlachaki ◽  
Dimitra Melissaridou ◽  
Konstantinos Vlasis ◽  
...  

Dr Marika Daniilidou was born in 1902 in Asia Minor. Her family was forced to immigrate to Greece, in 1922. Despite the horrendous difficulties of the era, she pursued undergraduate and postgraduate studies in the University of Berlin, Germany, and she specialized in orthopaedic surgery. In 1937, she became the first female certified orthopaedic surgeon in Greece. In 1947, she was the only female orthopaedic surgeon among the 22 founders of the Hellenic Association of Orthopaedic Surgery and Traumatology (HAOST). She became a true role model for the next generations of Greek women surgeons.


2021 ◽  
pp. 155335062110592
Author(s):  
Elif Bilgic ◽  
Andrew Gorgy ◽  
Meredith Young ◽  
Samira Abbasgholizadeh-Rahimi ◽  
Jason M. Harley

2021 ◽  
pp. 155335062110599
Author(s):  
Ayhan Şahin ◽  
Onur Baran ◽  
Ahmet Gültekin ◽  
Gülcan Gücer Şahin ◽  
Tolga Ersözlü ◽  
...  

Introduction The cervical plexus block (CPB) has been used for a long time for both analgesia and anesthesia in carotid endarterectomy and thyroid operations. To be unfamiliar with the technique and its perceived difficulty, potential risks, and possible adverse effects such as intravascular injection has limited broader use before the practical use of ultrasound. We hypothesize that the cervical plexus block can provide adequate anesthesia in tracheostomy cases and provide excellent anesthesia comfort when combined with a translaryngeal block. Methods This double-blinded, randomized 29 patients undergoing primary tracheostomy operation to receive either CPB (Group S) or CPB with translaryngeal block (Group ST). The primary outcome was cumulated analgesic consumption during the first 24 postoperative hours. Secondary outcomes were as follows: pain related to incision, patient tolerance as assessed by tracheostomy cannula comfort score, cough and gag, pain at rest, nausea and vomiting, and time to first analgesic demand. Results The patient tolerance for tracheostomy was higher in Group ST than Group S. The median tracheostomy cannula comfort score was 4.0 in Group S. In contrast, the median score was significantly lower in group ST (P<.001). The cough and gag reflex scores were significantly lower in Group ST than Group S (1.0 vs 4.0, P<.001). Conclusion This trial supported the hypothesis that the CPB combined with the translaryngeal block yields excellent anesthesia for tracheostomies. The technique we briefly described, in a way, is the equivalent of awake fiberoptic intubation to awake tracheostomy with minimal sedation adjusted according to airway patency.


2021 ◽  
pp. 155335062110527
Author(s):  
Andrea Balla ◽  
Livia Palmieri ◽  
Diletta Corallino ◽  
Francesca Meoli ◽  
Maria Carlotta Sacchi ◽  
...  

Background To evaluate the impact of laparoscopic sleeve gastrectomy (LSG) and gastric bypass (LGB) on gastroesophageal reflux disease (GERD). Methods GERD was evaluated by the Modified Italian Gastroesophageal reflux disease—Health-Related Quality of Life (MI-GERD-HRQL) questionnaire, pH-manometry, endoscopy, and Rx-esophagogram, before and 12 months after surgery. Based on these exams, patients without GERD underwent LSG, and patients with GERD underwent LGB. Results Thirteen and six patients underwent LSG and LGB, respectively. After LSG, the only statistically significant difference observed at pH-manometry was the median DeMeester score, from 5.7 to 22.7 (P = .0026). De novo GERD occurred in 6 patients (46.2%), with erosive esophagitis in one. The median MI-GERD-HRQL score improved from 3 to 0. Overall, nine patients underwent LGB, but three were lost to follow-up. Preoperative pH-manometry changed the surgical indication from LSG to LGB in 7 out of 9 patients (77.8%). Six patients who underwent LGB completed the study, and at pH-manometry, statistically significant differences were observed in the percentage of total acid exposure time, with the number of reflux episodes lasting >5 minutes and DeMeester score (P = .009). The median MI-GERD-HRQL score improved from 6.5 to 0. Statistically significant differences were not observed at endoscopy and Rx-esophagogram findings in both groups. Conclusions LSG has a negative impact on GERD, even in patients without preoperative GERD. LGB confirmed to be the intervention of choice in patients with GERD. Preoperative pH-manometry may identify patients with silent GERD, to candidate them to LGB rather than LSG. pH-manometry should be used more liberally to establish the correct surgical indication on objective grounds.


2021 ◽  
pp. 155335062110532
Author(s):  
Karen Hughes Miller ◽  
Erica Sutton ◽  
George Pantalos

Background: Preparation for exploration class space flight requires planning to support human life in many circumstances including healthcare emergencies such as the need for acute surgical care, a notable example of which is appendicitis. Although performing a laparoscopic appendectomy on Earth is routine for a trained general surgeon, it is far from routine for a non-surgeon working in microgravity where IVs do not drip, drains do not drain, and gaseous anesthetic is out of the question. Because the procedure for laparoscopic appendectomy is so well documented, it was the ideal procedure on which to base a study on how to deconstruct a surgical procedure to examine all actions, skills, equipment, and supplies needed for success by non-surgeons working in an extreme environment. Study Design: Our challenge was to develop a task analysis model robust enough to include 3 performers (in the roles of surgeon, assistant, and anesthesiologist) including each action and instrument or supply item needed in chronological order, while indicating which actions were completed independently and which were done in tandem. We also had to indicate where variations in the actions would be determined by the negative response of the patient (failure mode), and which actions and supply items needed further research to accommodate working in microgravity. We opted to begin with a hierarchical task analysis model (HTA) because the steps in the task are sequential; but we expanded the typical linear presentation of data to a multi-column spread sheet with active links to instructional video clips where needed. Content development was an iterative process beginning with a scoping review of literature to select a baseline task analysis of the procedure. The SAGES 2010 approach was selected as most comprehensive, but logically focused on the surgeon’s performance with few references to the assistant or anesthesiologist. Those gaps were filled using content from training materials developed for surgical technicians and nurse anesthetists. The second step was an expert review of the spread sheet to identify gaps and inadequacies. The third step was a minute comparison of spread sheet content to actions and equipment as documented on 2 videotapes of the procedure performed by our team surgeon on otherwise healthy patients. The final review was accomplished by replicating the procedure on 360° video (with narration) using the spread sheet as a guide, then cross checking and correcting the spread sheet to correspond with the 360° video. This test procedure was performed on a lightly preserved, fresh cadaver since working at that very slow, deliberate pace would not be in the best interest of an actual patient. Results: In this study, simulation was actually used to test the expanded HTA rather than to evaluate a learner. The final spread sheet included 178 lines, 13 columns, 13 illustrations, and 4 active links to instructional video clips. Thirteen items or issues were identified as needing further research, 8 action sequences were identified as generalizable skills, and 27 supply or equipment items were identified as multipurpose. Excluding the pharmaceuticals necessary for IV general anesthesia (that research is on-going), we were able to replicate a laparoscopic appendectomy on a fresh cadaver using no more than 30 items. The procedure was done using 3 trocars with very few instrument exchanges through the trocars since the surgical assistant assumed the role of laparoscopic camera operator during the procedure. Conclusion: An expanded HTA of a surgical procedure can produce many useful outcomes including integrated training for all team members, review of instrumentation and supplies and, in our case, identifying areas for adapting to an extreme environment. Using an interdisciplinary team including instructional designers, subject matter experts from medicine and biomedical engineering, and media production enriched the process.