DIAGNOSTIC ACCURACY OF ACETIC ACID OR CRYSTAL VIOLET ENHANCED NARROW BAND IMAGING (NBI) FOR DETECTING GASTRIC INTESTINAL METAPLASIA (MAPS) USING EGGIM AND SIMPLIFIED NBI CLASSIFICATION

2019 ◽  
Author(s):  
I Lyutakov ◽  
R Nakov ◽  
H Valkov ◽  
A Dimov ◽  
P Penchev ◽  
...  
PLoS ONE ◽  
2017 ◽  
Vol 12 (1) ◽  
pp. e0170957 ◽  
Author(s):  
Jie Sha ◽  
Pin Wang ◽  
Bingliang Zhu ◽  
Minghui Zhu ◽  
Xueliang Li ◽  
...  

2020 ◽  
Vol 08 (04) ◽  
pp. E488-E497
Author(s):  
Kotaro Shibagaki ◽  
Norihisa Ishimura ◽  
Takafumi Yuki ◽  
Hideaki Taniguchi ◽  
Masahito Aimi ◽  
...  

Abstract Background and study aims Magnification endoscopy with narrow-band imaging (NBIME) and NBIME with acetic acid enhancement (A-NBIME) enable visualization of the vascular and microstructural patterns of colorectal polyp. We compared the diagnostic accuracy and reproducibility of white light endoscopy (WLE), NBIME, and A-NBIME for predictive histologic diagnosis. Patients and methods Consecutive colorectal polyps (N = 628; 38 hyperplasias, 488 adenomas, 72 M-SM1 cancers, and 30 SM2 cancers) were photographed with WLE, NBIME, and A-NBIME. Endoscopic images were independently reviewed by three experts, according to the traditional criteria for WLE, the Japan NBI Expert Team classification for NBIME, and pit pattern classification for A-NBIME to compare diagnostic accuracy and interobserver diagnostic agreement among modalities. Results The specificity (95 % confidence interval) of hyperplasia and SM2 cancer with WLE were 98.2 % (96.8 %–99.1%) and 99.4 % (98.5 %–99.9 %), respectively, showing high accuracy for endoscopic resection without magnifying observation. Diagnostic accuracy of WLE, NBIME, and A-NBIME was 80.8 % (77.4 %–83.8 %), 79.3 % (75.9 %–82.4 %), and 86.1 % (83.2 %–88.7 %), respectively, showing the highest accuracy for A-NBIME among modalities (P < .05). NBIME showed a lower PPV for M-SM1 cancer (P < .05), as with WLE (P = .08) compared to A-NBIME. Fleiss’s kappa values for WLE, NBIME, and A-NBIME diagnosis were 0.43 (0.39 – 0.46), 0.52 (0.49 – 0.56) and 0.65 (0.62 – 0.69), respectively, showing insufficient reproducibility of WLE and superiority of A-NBIME among modalities. Conclusion WLE showed high accuracy for endoscopic resection of colorectal polyps in expert diagnosis. NBIME demonstrated a higher diagnostic reproducibility than WLE. A-NBIME showed possible superiority among modalities in both diagnostic accuracy and reproducibility.


Endoscopy ◽  
2006 ◽  
Vol 38 (8) ◽  
pp. 819-824 ◽  
Author(s):  
N. Uedo ◽  
R. Ishihara ◽  
H. Iishi ◽  
S. Yamamoto ◽  
S. Yamamoto ◽  
...  

2017 ◽  
Vol 86 (5) ◽  
pp. 857-865 ◽  
Author(s):  
James L. Buxbaum ◽  
David Hormozdi ◽  
Mario Dinis-Ribeiro ◽  
Christianne Lane ◽  
Diogo Dias-Silva ◽  
...  

2005 ◽  
Vol 61 (5) ◽  
pp. AB184 ◽  
Author(s):  
Noriya Uedo ◽  
Ryu Ishihara ◽  
Hiroyasu Iishi ◽  
Hiroyuki Narahara ◽  
Tomiko Mikuni ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document