scholarly journals Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching

2005 ◽  
Vol 10 (1) ◽  
pp. 37-43 ◽  
Author(s):  
Sorin Blendea ◽  
Kort Eckman ◽  
Branislav Jaramaz ◽  
Timothy Levison ◽  
Anthony DiGioia
2016 ◽  
Vol 88 (1) ◽  
pp. 10-17 ◽  
Author(s):  
Kurt G Seagrave ◽  
Anders Troelsen ◽  
Henrik Malchau ◽  
Henrik Husted ◽  
Kirill Gromov

Author(s):  
Henryk Haffer ◽  
Zhen Wang ◽  
Zhouyang Hu ◽  
Christian Hipfl ◽  
Matthias Pumberger

Abstract Introduction Spinopelvic mobility was identified as a contributing factor for total hip arthroplasty (THA) instability. The influence of spinopelvic function on acetabular cup positioning has not yet been sufficiently investigated in a prospective setting. Therefore, our study aimed (1) to assess cup inclination and anteversion in standing and sitting based on spinopelvic mobility, (2) to identify correlations between cup position and spinopelvic function, (3) and to determine the influence of the individual spinal segments, spinal sagittal balance, and spinopelvic characteristics on the mobility groups. Materials and methods A prospective study assessing 197 THA patients was conducted with stereoradiography in standing and sitting position postoperatively. Two independent investigators determined cup anteversion and inclination, C7-Sagittal vertical axis, cervical lordosis (CL), thoracic kyphosis (TK), lumbar lordosis (LL), sacral slope, pelvic tilt (PT), anteinclination (AI), and pelvic femoral angle (PFA). Spinopelvic mobility is defined based on ∆PT = PTstanding − PTsitting as ∆PT < 10° stiff, ∆PT ≥ 10–30° normal, and ∆PT > 30° hypermobile. Pearson coefficient represented correlations between the cup position and spinopelvic parameters. Results Significant differences were demonstrated for cup anteversion (stiff/hypermobile 29.3°/40.1°; p < 0.000) and inclination (stiff/hypermobile 43.5°/60.2°; p < 0.000) in sitting, but not in standing position. ∆ (standing/sitting) of the cup anteversion (stiff/neutral/hypermobile 5.8°/12.4°/19.9°; p < 0.000) and inclination (stiff/neutral/hypermobile 2.3°/11.2°/18.8°; p < 0.000) revealed significant differences between the mobility groups. The acetabular cup position in sitting, was correlated with lumbar flexibility (∆LL) and spinopelvic mobility. Significant differences were detected between the mobility types and acetabular orientation (AI sit:stiff/hypermobile 47.6°/65.4°; p < 0.000) and hip motion (∆PFA:stiff/hypermobile 65.8°/37.3°; p < 0.000). Assessment of the spinal segments highlighted the role of lumbar flexibility (∆LL:stiff/hypermobile 9.9°/36.2°; p < 0.000) in the spinopelvic complex. Conclusion The significantly different acetabular cup positions in sitting and in the ∆ between standing and sitting and the significantly altered spinopelvic characteristics in terms of stiff and hypermobile spinopelvic mobility underlined the consideration for preoperative functional radiological assessment. Identifying the patients with altered spinopelvic mechanics due to a standardized screening algorithm is necessary to provide safe acetabular cup positioning. The proximal spinal segments appeared not to be involved in the spinopelvic function.


2001 ◽  
Vol 388 ◽  
pp. 135-142 ◽  
Author(s):  
Kazuo Hirakawa ◽  
Naoto Mitsugi ◽  
Tomihisa Koshino ◽  
Tomoyuki Saito ◽  
Yasusuku Hirasawa ◽  
...  

2021 ◽  
Author(s):  
Joo-Hyoun Song ◽  
Yong-Sik Kim ◽  
Soon-Yong Kwon ◽  
Young-Wook Lim ◽  
Jiyoung Jung ◽  
...  

Abstract Background: Acetabular prosthesis positioning in total hip arthroplasty (THA) is crucial in reducing the risk of dislocation. There has been minimal research on the proper way to put the acetabular components into the safe zone intraoperatively. Assessment of version by intraoperative imaging intensifier is very valuable. The value of Widmer’s method, using the intraoperative C-arm available to determine cup anteversion was assessed.Methods: 101 hips in 91 patients who underwent primary THA were eligible for inclusion. Utilizing intraoperative C-arm images, measurement was performed using the technique described by Widmer. The values obtained using 3D computed tomography postoperatively, which determined the anteversion of the acetabular component, were regarded as the reference standard.Results: The method of Widmer obtained values similar to those obtained using 3D computed tomography and was considered accurate (n.s.). All 101 hips were positioned in the set target zone. Among the 101 hips, the cup position in nine hips (8.9%) was changed. The dislocation rate in our study was 1.0% with all dislocations occurring in hips placed in the target zone. The mean Harris hip score after THA in one year was 94.2 (82-98).Conclusions: The method of Widmer was accurate using intraoperative imaging intensifier for the measurement of the anteversion of the acetabular component during THA, with reference to the anteversion obtained from the 3D computed tomography. Also, utilizing intraoperative C-arm imaging was very useful because it allowed for correction of the position of the acetabular cup.


Sign in / Sign up

Export Citation Format

Share Document