Final report of Key Comparison APMP.EM.RF-K3.F: Bilateral Comparison of Ka-band Horn Antenna Gain

Metrologia ◽  
2015 ◽  
Vol 52 (1A) ◽  
pp. 01023-01023 ◽  
Author(s):  
Jin-Seob Kang ◽  
No-Weon Kang ◽  
Masanobu Hirose ◽  
Koji Komiyama
Metrologia ◽  
2021 ◽  
Vol 59 (1A) ◽  
pp. 07001
Author(s):  
Fernando García ◽  
Francisco Garcí ◽  
Orlando Pinzón ◽  
Sául García ◽  
Rául Hernandez ◽  
...  

Main text The present document reports the results of a bilateral comparison in the calibration of mass standards that was carried out between CESMEC (Chile) and CENAMEP AIP (Panamá). This comparison was carried out in the following nominal values: 200 mg, 1 g, 50 g, 200 g, 1 kg, 2 kg, and 10 kg. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


Metrologia ◽  
2021 ◽  
Vol 59 (1A) ◽  
pp. 07002
Author(s):  
Josephat Obwoge Bangi ◽  
Mark Seidel ◽  
David Kimetto ◽  
Rolf Kumme ◽  
Henry Rotich ◽  
...  

Main text This bilateral comparison of Force Standard Machines (FSM) named AFRIMETS.M. F-S1 was carried out in the force range from 1 kN to 100 kN between Physikalisch-Technische Bundesanstalt (PTB) of Germany as the pilot laboratory and Kenya Bureau of Standards (KEBS) of Kenya as the participant laboratory. KEBS had already participated in the APMP.M. F-K2 key comparison where measurements were made only at 50 kN and 100 kN force steps. Therefore, this bilateral comparison was planned to thoroughly compare the KEBS FSM and the PTB Deadweight Machines in wider force steps than those of the APMP.M. F-K2 key comparison and thus it had no corresponding key-comparisons values to be linked to at that time. PTB provided two force transducers for the supplementary comparison with 10 kN and 100 kN nominal capacities. The comparison method called "DKD" procedure was used. This procedure has already been used in several comparisons in Germany and other countries. The purpose to this comparison is to give support to the uncertainty claims for KEBS and will be used to determine the Calibration and Measurement Capability (CMC). In addition, this comparison will provide metrological proof of the application for a CMC entry in the BIPM Key Comparison Database (KCDB). This report describes the scheme and results of the comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


Metrologia ◽  
2012 ◽  
Vol 49 (1A) ◽  
pp. 01006-01006
Author(s):  
E Goebel ◽  
Wan-Seop Kim ◽  
N Fletcher ◽  
M Stock

Sign in / Sign up

Export Citation Format

Share Document