scholarly journals Quality Control of the Fuzi Lizhong Pill Through Simultaneous Determination of 16 Major Bioactive Constituents by RRLC–MS-MS

2018 ◽  
Vol 56 (6) ◽  
pp. 541-554 ◽  
Author(s):  
Yun-zhuo Dong ◽  
Zhen-li Liu ◽  
Yuan-yan Liu ◽  
Zhi-qian Song ◽  
Na Guo ◽  
...  
2013 ◽  
Vol 8 (9) ◽  
pp. 1934578X1300800
Author(s):  
Somendu K. Roy ◽  
Khemraj Bairwa ◽  
Jagdeep Grover ◽  
Amit Srivastava ◽  
Sanjay M. Jachak

The leaves of Vitex negundo have been reported to contain various bioactive constituents including iridoids and flavonoids. This is the first report on the simultaneous determination of iridoids and flavonoids by HPLC in three different samples of V. negundo leaves collected from three regions of India. Separation of iridoids and flavonoids was accomplished by HPLC and further elaborated for their quantification in V. negundo leaves using a C-18 column with detection at 254 and 330 nm, respectively. The developed HPLC method showed good linearity (r2≥0.999), high precision (RSD<5%) and a good recovery (99.3–103.0%) of the compounds. All the validation parameters of the developed HPLC were found to be within the permissible limits according to the ICH guidelines. The developed method was robust, accurate and reliable for the quality control of V. negundo leaves.


2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Jin Li ◽  
Qiu-Hong Zhang ◽  
Jun He ◽  
Er-wei Liu ◽  
Xiu-mei Gao ◽  
...  

An improved LC-MS/MS method was developed for simultaneous determination of eleven bioactive constituents of Radix Angelicae Pubescentis and its related preparations. It was the first report on the quantification of bioactive constituents in different preparations of Radix Angelicae Pubescentis by LC-MS/MS analytical method. These samples were separated with an Agilent Zorbax Extend reversed-phase C18 column (1.8 μm, 4.6 × 100 mm) by linear gradient elution using aqueous ammonium acetate and acetonitrile as mobile phase. The flow rate was 0.3 mL min−1. The eleven bioactive constituents showed good regression(R>0.990)within test ranges and the recoveries were in the range of 87.1–110%. The limit of detections and quantifications for most of the major constituents were less than 0.5 and 1.0 ng mL−1, respectively. All results indicated that the developed method could be readily utilized as a suitable quality control method for Radix Angelicae Pubescentis and related preparations.


2020 ◽  
Vol 17 (1) ◽  
pp. 47-56
Author(s):  
Shun Liu ◽  
Xun Wang ◽  
Kaiping Zou ◽  
Wei Liu ◽  
Cunyu Li ◽  
...  

Background: Zishen Tongguan (ZSTG) capsules were prepared at the Affiliated Hospital of Nanjing University of Chinese Medicine and have been proven to be clinically effective for treating pyelonephritis and benign prostatic hyperplasia. However, the quality standards are not ideal; a comprehensive study of the “quality markers” (Q-markers), the chemicals inherent in traditional Chinese medicine and its preparations, has not been carried out. Experimental Methods: In this paper, a sensitive and specific ultra-high-performance liquid chromatographictandem mass spectrometry (UHPLC-MS/MS) method was developed for the simultaneous determination of eight potential Q-markers of ZSTG, including timosaponin A3, berberine, jatrorrhizine, phellodendrine, palmatine, mangiferin, neomangiferin, and timosaponin BII. A Kromasil 100-3.5 C18 column was used with a mobile phase of 0.2% formic acid with acetonitrile, and gradient elution at a flow rate of 0.2 mL/min was achieved in 13 minutes and used for separation. Detection was performed in positive/negative mode with multiple reaction monitoring (MRM). Results: The analytical method was validated in terms of the sensitivity, linearity, accuracy, precision, repeatability, stability and recovery. The method established here was successfully applied to study the potential Q-markers in 8 batches of commercial samples, which demonstrated its use in improving the quality control of ZSTG. Conclusion: The developed method had high repeatability and accuracy and was suitable for the simultaneous analysis of multiple Q-markers, which may provide a new basis for the comprehensive assessment and overall quality control of ZSTG.


2012 ◽  
Vol 7 (9) ◽  
pp. 1934578X1200700 ◽  
Author(s):  
Haijiang Zhang ◽  
Wei Yao ◽  
Yunyun Chen ◽  
Peipei He ◽  
Yao Chen ◽  
...  

A simple and reliable HPLC method was developed and validated for the simultaneous quantification of four major constituents in Semen Vaccariae. The chromatographic separation was performed on an Agilent Zorbax SB-C18 column with gradient elution using methanol and water. The calibration curves showed good linearity of R2 > 0.9999 with LOQs (S/N = 10) of 0.20–1.16 μg/mL. The precision was evaluated by intra- and inter-day assays and R.S.D. values were less than 2.09%. The recovery rates were between 97.0% and 105.0%. The developed method was applied to the quantitative analysis of Semen Vaccariae and its stir-fried products. During the stir-frying process, vaccarin degraded and yielded isovitexin-2″- O-arabinoside. The preferable stir-frying temperature is around 120°C. The developed HPLC method can be applied to the quality control of crude and stir-fried Semen Vaccariae.


Sign in / Sign up

Export Citation Format

Share Document