scholarly journals P2638Comparison of in-stent responses in 8 month between durable polymer and bioabsorbable polymer everolimus-eluting stent: serial observation with angioscopy and optical coherence tomography

2018 ◽  
Vol 39 (suppl_1) ◽  
Author(s):  
D Kitano ◽  
T Takayama ◽  
D Fukamachi ◽  
S Migita ◽  
T Morikawa ◽  
...  
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
Y Matsuhiro ◽  
M Nishino ◽  
H Nakamura ◽  
K Yasumoto ◽  
A Tanaka ◽  
...  

Abstract Background New generation drug eluting stents (DES) have improved target vessel failure as compared with early generation DES and bare metal stent. Contemporary several new generation DES are different each other regarding strut thickness and drug and polymer type. A little is known about which stent induces a more favorable vascular healing at follow up. Purpose In this study, we compared the vascular healing at 8-month follow up by optical coherence tomography (OCT) between 4 different kinds of new generation DES. Methods We enrolled 112 consecutive patients (121 lesions) who underwent PCI using 4 kinds of new generation DES including biodegradable-polymer everolimus-eluting stents (BP-EES), biodegradable-polymer sirolimus-eluting stents (BP-SES), durable-polymer everolimus-eluting stents (DP-EES) and durable-polymer zotarolimus-eluting stents (DP-ZES) and who underwent 8-month follow up angiogram and OCT between July 2016 and April 2018. We compared the OCT parameters including percentage of covered struts, uncovered struts, well-apposed and uncovered struts, malapposed strut and mean neointimal hyperplasia (NIH) thickness between them. Results BP-EES consisted of 29 lesions, BP-SES consisted of 25 lesions, DP-EES consisted of 38 lesions and DP-ZES consisted of 29 lesions. A total of 734 frames with 5163 struts in BP-EES, 481 frames with 4214 struts in BP-SES, 783 frames with 6119 struts in DP-EES and 583 frames with 4708 struts in DP-ZES were analyzed. As shown in a table, mean NIH thickness was significantly higher in BP-EES and BP-SES. Thus, we compared the OCT parameters between durable-polymer (DP) group including DP-ZES and DP-EES and biodegradable-polymer (BP) group including BP-EES and BP-SES. The percentage of uncovered struts was significantly lower and mean NIH thickness was significantly higher in BP group than DP group. Results of OCT parameters BP-EES (n=29) BP-SES (n=25) DP-EES (n=38) DP-ZES (n=29) P value BP group (n=54) DP group (n=67) P value Covered struts (%) 89.5±13.6 92.4±8.6 85.5±17.5 85.0±17.7 0.29 90.9±11.6 85.3±17.4 0.08 Uncovered struts (%) 8.8±10.8 7.1±8.7 14.5±17.5 15.0±17.7 0.14 8.0±9.9 14.7±17.4 0.03 Well-apposed and uncovered struts (%) 7.9±9.9 5.9±7.7 11.7±13.1 12.3±14.0 0.15 7.0±8.9 11.9±13.4 0.04 Malapposed struts (%) 0.8±1.6 1.3±2.2 2.7±5.8 2.7±4.7 0.33 1.0±1.9 2.7±5.3 0.07 Mean NIH thickness (μm) 102±57 121±48 78±28 88±33 <0.01 111±53 82±31 <0.01 Conclusion The present OCT study demonstrated that delayed neointimal healing characterized by the presence of uncovered struts and lower mean NIH thickness was less common in BP group than DP gruop. Biodegradable-polymer may be more favorable than durable-polymer from the point of view of vascular healing.


2009 ◽  
Vol 31 (2) ◽  
pp. 165-176 ◽  
Author(s):  
P. Barlis ◽  
E. Regar ◽  
P. W. Serruys ◽  
K. Dimopoulos ◽  
W. J. van der Giessen ◽  
...  

2019 ◽  
Vol 35 (4) ◽  
pp. 463-473 ◽  
Author(s):  
Wan Azman Wan Ahmad ◽  
Takaharu Nakayoshi ◽  
Ahmad Syadi Mahmood Zuhdi ◽  
Muhammad Dzafir Ismail ◽  
Imran Zainal Abidin ◽  
...  

Abstract Recent clinical trials have raised concerns about the safety and efficacy of ABSORB™ bioresorbable vascular scaffolds (BVS). The difference in the vascular healing process between SYNERGY™ bioabsorbable polymer-coated everolimus-eluting stents (BP-EES) and BVS remains unclear. The aim of the ENHANCE study was to compare vascular healing on BP-EES versus BVS by optical coherence tomography (OCT) and coronary angioscopy (CAS) at 4- and 12-month follow-ups. This is a prospective, non-randomized, single center clinical trial. Thirteen eligible patients with multivessel disease were enrolled. BP-EES and BVS were simultaneously implanted in the same patients, but in different coronary vessels. Imaging follow-up with both OCT and CAS was completed in 11 patients at 12 months. Neointimal coverage rates were similar between the two groups based on OCT measurements. The neointimal thickness of BP-EES was significantly thicker at the 12th month than at the 4th month, whereas the neointimal thickness of BVS did not change between the measurements taken at the 4th and 12th month. Existence of intra-stent thrombus was significantly higher in the BVS group, compared to the BP-EES group. On the other hand, CAS revealed that red-thrombi and yellow-plaque were more frequently observed in BVS at 4 months and up to 12-month follow-ups than in BP-EES. These findings suggested that the evidence of instability remained up to 12 months in the vascular healing with BVS, compared to that with BP-EES. Vascular healing of the stented wall was recognized at the very early phase after BP-EES implantation. However, vascular healing with BVS was still incomplete after 12 months.


Sign in / Sign up

Export Citation Format

Share Document