ED50and ED95of Intrathecal Hyperbaric Bupivacaine Coadministered with Opioids for Cesarean Delivery

2004 ◽  
Vol 100 (3) ◽  
pp. 676-682 ◽  
Author(s):  
Yehuda Ginosar ◽  
Edward Mirikatani ◽  
David R. Drover ◽  
Sheila E. Cohen ◽  
Edward T. Riley

Background Successful cesarean delivery anesthesia has been reported with use of small doses (5-9 mg) of intrathecal bupivacaine coadministered with opioids. This double-blind, randomized, dose-ranging study determined the ED50 and ED95 of intrathecal bupivacaine (with adjuvant opioids) for cesarean delivery anesthesia. Methods Forty-two parturients undergoing elective cesarean delivery with use of combined spinal-epidural anesthesia received intrathecal hyperbaric bupivacaine in doses of 6, 7, 8, 9, 10, 11, or 12 mg in equal volumes with an added 10 microg intrathecal fentanyl and 200 microg intrathecal morphine. Sensory levels (pinprick) were evaluated every 2 min until a T6 level was achieved. The dose was a success(induction) if a bilateral T6 block occurred in 10 min; otherwise, it was a failure(induction). In addition to being a success(induction), the dose was a success(operation) if no intraoperative epidural supplement was required; otherwise, it was a failure(operation). ED50 and ED95 for both success(induction) and success(operation) were determined with use of a logistic regression model. Results ED50 for success(induction) and success(operation) were 6.7 and 7.6 mg, respectively, whereas the ED95 for success(induction) and success(operation) were 11.0 and 11.2 mg. Speed of onset correlated inversely with dose. Although no clear advantage for low doses could be demonstrated (hypotension, nausea, vomiting, pruritus, or maternal satisfaction), this study was underpowered to detect significance in these variables. Conclusions The ED95 of intrathecal bupivacaine under the conditions of this study is considerably in excess of the low doses proposed for cesarean delivery in some recent publications. When doses of intrathecal bupivacaine less than the ED95, particularly near the ED50, are used, the doses should be administered as part of a catheter-based technique.

2005 ◽  
Vol 103 (3) ◽  
pp. 606-612 ◽  
Author(s):  
Brendan Carvalho ◽  
Marie Durbin ◽  
David R. Drover ◽  
Sheila E. Cohen ◽  
Yehuda Ginosar ◽  
...  

Background The ideal intrathecal isobaric bupivacaine dose for cesarean delivery anesthesia is uncertain. While small doses (5-9 mg) of bupivacaine may reduce side effects such as hypotension, they potentially increase spinal anesthetic failures. This study determined the ED50 and ED95 of intrathecal isobaric bupivacaine (with adjuvant opioids) for cesarean delivery. Methods After institutional review board approval and written informed consent were obtained, 48 parturients undergoing elective cesarean delivery under combined spinal-epidural anesthesia were enrolled in this double-blind, randomized, dose-ranging study. Patients received a 5-, 6-, 7-, 8-, 9-, 10-, 11-, or 12-mg intrathecal isobaric bupivacaine dose with 10 microg fentanyl and 200 microg morphine. Overall anesthetic success was recorded when no intraoperative epidural supplement was required during the cesarean delivery. ED50 and ED95 values for overall anesthetic success were determined using a logistic regression model. Results ED50 and ED95 values for overall anesthetic success were 7.25 and 13.0 mg, respectively. No advantages for low doses could be demonstrated with regard to hypotension, nausea, vomiting, pruritus, or maternal satisfaction, although this study was underpowered to detect significant differences in secondary outcome variables. Conclusions The ED50 and ED95 values (7.25 and 13.0 mg, respectively) for intrathecal isobaric bupivacaine in this circumstance are similar to values the authors determined recently for hyperbaric bupivacaine using similar methodology. These ED50 and ED95 values are significantly higher than those advocated in previous reports in which success was claimed using lower intrathecal bupivacaine doses. The current study used stricter criteria to define "successful" anesthesia and support the use of larger bupivacaine doses to ensure adequate patient comfort.


Sign in / Sign up

Export Citation Format

Share Document