Flow, radiofrequency pulse sequences, and gradient magnetic fields

1991 ◽  
Vol 3 (3) ◽  
pp. 1???11
Author(s):  
Thomas J. Masank ◽  
Jean Tkach ◽  
Mark Glicklich
2000 ◽  
Vol 321 (3-4) ◽  
pp. 205-215 ◽  
Author(s):  
Marina Carravetta ◽  
Mattias Edén ◽  
Xin Zhao ◽  
Andreas Brinkmann ◽  
Malcolm H Levitt

2011 ◽  
Vol 213 (2) ◽  
pp. 247-273
Author(s):  
Ray Freeman ◽  
Stewart P. Kempsell ◽  
Malcolm H. Levitt

2015 ◽  
Vol 74 (3) ◽  
pp. spcone-spcone
Author(s):  
Emre Kopanoglu ◽  
R. Todd Constable

1980 ◽  
Vol 38 (3) ◽  
pp. 453-479 ◽  
Author(s):  
Ray Freeman ◽  
Stewart P Kempsell ◽  
Malcolm H Levitt

2016 ◽  
Vol 34 (3) ◽  
pp. 326-333 ◽  
Author(s):  
Jingwei Sheng ◽  
Yun Liu ◽  
Yuhui Chai ◽  
Weinan Tang ◽  
Bing Wu ◽  
...  

2008 ◽  
Vol 2 (3) ◽  
pp. 222-228 ◽  
Author(s):  
Andrea Lavinio ◽  
Sally Harding ◽  
Floor Van Der Boogaard ◽  
Marek Czosnyka ◽  
Peter Smielewski ◽  
...  

Object Exposing patients with ventricular shunts to magnetic fields and MR imaging procedures poses a significant risk of unintentional changes in shunt settings. Shunt valves can also generate considerable imaging artifacts. The purpose of this study was to determine the magnetic field safety and MR imaging compatibility of 5 adjustable models of hydrocephalus shunts. Methods The Codman Hakim (regular and with SiphonGuard), Miethke ProGAV, Medtronic Strata, Sophysa Sophy and Polaris programmable valves were tested in a low-intensity magnetic field, and then translational attraction (TA), magnetic torque (MT), and volume of artifacts on T1-weighted spin echo (SE) and gradient echo (GE) pulse sequences in a 3-T MR imaging unit were measured. Results The ProGAV and Polaris valves were immune to unintentional reprogramming by magnetic fields up to 3 T. Other valves randomly changed settings, starting from the intensity of field: Sophy valve 24 mT, Strata valve 30 mT, and both Codman Hakim programmable valves from 42 mT. Shunt performances in the 3-T MR imaging unit are reported in the order of compatibility: 1) Codman Hakim regular, TA = 0.005 N, MT = 0.000 Nm, GE = 30 cm3, SE = 2 cm3; 2) Miethke ProGAV, TA = 0.001 N, MT = 1.4 × 10−3 Nm, GE = 231 cm3, SE = 13 cm3; 3) Codman Hakim with SiphonGuard, TA = 0.005 N, MT = 2.3 × 10−3 Nm, GE = 233 cm3, SE = 19 cm3; 4) Medtronic Strata, TA = 0.27 N, MT = 18.0 × 10−3 Nm, GE = 484 cm3, SE = 86 cm3; 5) Sophysa Sophy, TA = 0.82 N, MT = 38.9 × 10−3 Nm, GE = 758 cm3, SE = 72 cm3; and 6) Sophysa Polaris, TA = 0.80 N, MT = 39.6 × 10−3 Nm, GE = 954 cm3, SE = 100 cm3. Conclusions All valves, with the exception of the Polaris and ProGAV models, are prone to unintentional reprogramming when exposed to heterogeneous magnetic fields stronger than 40 mT. All tested valves can be considered safe for 3-T MR imaging. All valves generated a distortion of the MR image, especially the GE sequences.


1985 ◽  
Vol 145 (1) ◽  
pp. 1-8 ◽  
Author(s):  
SJ el Yousef ◽  
DM O'Connell ◽  
RH Duchesneau ◽  
MJ Smith ◽  
CA Hubay ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document