scholarly journals Hemodynamic and Hormonal Stress Responses to Endotracheal Tube and ProSeal Laryngeal Mask AirwayTMfor Laparoscopic Gastric Banding

2012 ◽  
Vol 117 (2) ◽  
pp. 309-320 ◽  
Author(s):  
Michele Carron ◽  
Stefano Veronese ◽  
Walter Gomiero ◽  
Mirto Foletto ◽  
Donato Nitti ◽  
...  

Background The stress responses from tracheal intubation are potentially dangerous in patients with higher cardiovascular risk, such as obese patients. The primary outcome objective of this study was to test whether, in comparison with the endotracheal tube (ETT), the Proseal™ Laryngeal Mask Airway (PLMA™) (Laryngeal Mask Airway Company, Jersey, United Kingdom) reduces blood pressure and norepinephrine responses and the amounts of muscle relaxants needed in obese patients. Methods We assessed hemodynamic and hormonal stress responses, ventilation, and postoperative recovery in 75 morbidly obese patients randomized to receive standardized anesthesia with either an ETT or the PLMA™ for laparoscopic gastric banding. Results In repeated-measures ANOVA, mean arterial blood pressure and plasma norepinephrine were significantly higher in the ETT group than in the PLMA™ group. In individual pairwise comparisons, blood pressure rose higher in ETT than PLMA™ patients after insertion and removal of airway devices, and after recovery. In ETT compared with PLMA™ patients, plasma norepinephrine was higher after induction of carboperitoneum (mean ± SD, 534 ± 198 and 368 ± 147 and pg/ml, P = 0.001), after airway device removal (578 ± 285 and 329 ± 128 pg/ml, P < 0.0001), and after recovery in postanesthesia care unit (380 ± 167 and 262 ± 95 and pg/ml, P = 0.003). Compared with use of the ETT, the PLMA™ reduced cisatracurium requirement, oxygen desaturation, and time to discharge from both the postanesthesia care unit and the hospital. Conclusions PLMA™ reduces stress responses and postoperative complaints after laparoscopic gastric banding.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Erol Karaaslan ◽  
Sedat Akbas ◽  
Ahmet Selim Ozkan ◽  
Cemil Colak ◽  
Zekine Begec

Abstract Background There are doubts among anesthesiologists on the use of the Laryngeal Mask Airway (LMA) in nasal surgeries because of concerns about the occurrence of blood leakages to the airway. We hypothesized that the use of LMA-Supreme (LMA-S) in nasal surgery is comparable with endotracheal tube (ETT) according to airway protection against blood leakage through the fiberoptic bronchoscopy, oropharyngeal leakage pressure (OLP), heart rate (HR), mean arterial pressure (MAP), and postoperative adverse events. Methods The present study was conducted in a prospective, randomized, single-blind, controlled manner on 80 patients, who underwent septoplasty procedures under general anesthesia, after dividing them randomly into two groups according to the device used (LMA-S or ETT). The presence of blood in the airway (glottis/trachea, distal trachea) was analyzed with the fiberoptic bronchoscope and a four-point scale. Both groups were evaluated for OLP; HR; MAP; postoperative sore throat, nausea, and vomiting; dysphagia; and dysphonia. Results In the fiberoptic evaluation of the airway postoperatively, less blood leakage was detected in both anatomic areas in the LMA-S group than in the ETT group (glottis/trachea, p = 0.004; distal trachea, p = 0.034). Sore throat was detected less frequently in the LMA-S group at a significant level in the 2nd, 6th, and 12th hours of postoperative period; however, other adverse events were similar in both groups. Hemodynamic parameters were not different between the two groups. Conclusion The present findings demonstrate that the LMA-S provided more effective airway protection than the ETT in preventing blood leakage in the septoplasty procedures. We believe that the LMA-S can be used safely and as an alternative to the ETT in septoplasty cases. Trial registration This trial is registered at the US National Institutes of Health (ClinicalTrials.gov) # NCT03903679 on April 5, 2019.


Sign in / Sign up

Export Citation Format

Share Document