Minimally Invasive Implantation of the Myopore Sutureless Myocardial Pacing Lead

Author(s):  
Fabrizio Ceresa ◽  
Fabrizio Sansone ◽  
Giuseppe Calvagna ◽  
Maria Paola Maiorana ◽  
Giuseppe Busà ◽  
...  

Cardiac resynchronization therapy improves symptoms and survival of patients with congestive heart failure. Usually, the transvenous placement of the left ventricular lead is feasible, but in case of anatomic abnormalities of the coronary sinus, an unintended left phrenic nerve stimulation, a dislodgement of the percutaneous electrode, or a loss of capture of the electrode, surgical treatment should be considered. From January 2010 to September 2011, 15 patients underwent surgical implantation of the left ventricular lead after failure of transvenous placement. The MyoPore sutureless myocardial pacing lead (MSMPL) was implanted through a left minithoracotomy (~5 cm) under selective right lung ventilation. Time of surgery was 38.5 ± 3.0 minutes, and no surgical complications or early deaths are reported so far. After 10.7 ± 8.3 months of follow-up, no cases of late mortality, dislodgement, or loss of capture of the electrode are described. The use of the MSMPL is not novel, although the association with a minimally invasive approach may represent an alternative for a high-risk population. The screw-in of the lead ensures low impedance and threshold of stimulation (1.1 ± 0.6 V at 0.5 milliseconds) both in early and medium terms. In conclusion, in case of failure of the transvenous approach, the MSMPL may be easily implanted through a left minithoracotomy, and the results are noteworthy.

Author(s):  
Thijs Stoker ◽  
Theo J. Klinkenberg ◽  
Alexander H. Maass ◽  
Massimo A. Mariani

We describe two cases in which a biventricular implantable cardioverter defibrillator for cardiac resynchronization therapy had to be placed on the right side due to unsuitability of the left subclavian vein. Endocardial implantation of a left ventricular lead through the coronary sinus was previously attempted but was unsuccessful. Implantation of the epicardial left ventricular pacing lead was performed through video-assisted thoracic surgery on the left side. The connector end of the left ventricular pacing lead was tunnelized through the anterior mediastinum into the right pleural space. The right-sided pocket was then opened. A tunnel was created from the pocket to the thoracic wall, and the pleural space was entered over the second rib. The lead was retrieved from the right pleural space and connected with the Cardiac resynchronization therapy-device (CRT-D). Both procedures and postoperative periods were uneventful. Intrathoracic left-to-right tunneling of an epicardial left ventricular lead by video-assisted thoracic surgery is feasible and safe. It provides an alternative to subcutaneous tunneling.


Sign in / Sign up

Export Citation Format

Share Document